《ASTM E2273-2003 Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies《测定外保温层和装修层 EIFS)包覆的墙壁组件的排水效率的标准试验.pdf》由会员分享,可在线阅读,更多相关《ASTM E2273-2003 Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies《测定外保温层和装修层 EIFS)包覆的墙壁组件的排水效率的标准试验.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2273 03Standard Test Method forDetermining the Drainage Efficiency of Exterior Insulationand Finish Systems (EIFS) Clad Wall Assemblies1This standard is issued under the fixed designation E 2273; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method determines the drainage efficiency ofEIFS clad wall assembli
3、es when subjected to a water spray ratein accordance with Test Method E 331.1.2 The values stated in SI units are to be regarded as thestandard. The inch-pound units given in parenthesis are forinformation only.1.3 This standard may involve hazardous materials, opera-tions and equipment. This standa
4、rd does not purport to addressall of the safety concerns, if any, associated with its use. It isthe responsibility of the user of this standard to establishappropriate safety and health practices and determine theapplicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM St
5、andards:E 331 Test Method for Water Penetration of Exterior Win-dows, Curtain Walls, and Doors by Uniform Static AirPressure2E 2110 Terminology for Exterior Insulation and Finish Sys-tems (EIFS)33. Terminology3.1 Definitions used in this standard shall be in accordancewith Terminology E 2110.3.2 Def
6、initions of Terms Specific to This Standard:3.2.1 drainage effciencya percentage value based on theamount of water that passed through the test specimen and wascollected divided by the amount of water sprayed into the slotfault.3.2.2 test specimenthe entire assembled unit submittedfor testing as des
7、cribed in Section 7.3.2.3 test specimen slot faultan opening in the test speci-men where the insulation board, and other components havebeen removed exposing the weather-resistive barrier to whichwater spray is directed.3.2.4 water drainagethe ability of the test specimen todrain water.4. Summary of
8、 Test Method4.1 This test method consists of sealing a spray box to thetest specimen and then concentrating a water spray into the slotfault of the test specimen.5. Significance and Use5.1 This test method is a standard procedure for determiningthe drainage efficiency of an EIFS clad wall assembly.6
9、. Apparatus6.1 Spray Box, a transparent plastic, or equivalent, boxmeasuring 622 by 241 by 184 mm (2412 by 912 by 714 in.)containing a water spray system that is sealed to the testspecimen.6.2 Water Spray System, two spray nozzles installed in thespray box, oriented to apply all the water into the s
10、lot fault andlocated 13 mm (12 in.) from the open side of the spray box and150 mm (6 in.) to the right and left of vertical center of the slotfault. A pressure regulator, flow meter, and an inline water filterto the spray nozzles control the flow rate of water sprayed intothe slot fault. The water s
11、pray system shall deliver water at arate of 106 g (0.234 lb) per minute + 10% 0%.6.3 Drained Water Container(s), a container, or containers,tared to the nearest 1.0 g (0.002 lb) of sufficient size to retainthe water drained from the test specimen.6.4 Balance, with a capacity of 20 kg (45 lb) and acc
12、uracyof 1.0 g (0.002 lb).6.5 A means of collection such as a trough, to direct thedrained water to the drained water container. The collectionmethod may also be the tared container.7. Calibration of Flow Rate7.1 Collect the water from the water spray system in a taredcontainer for a period of 15 min
13、. Obtain the weight of thecollected water and adjust the flow rate if necessary to obtaina weight of water of 1590 g (3.5 lb) to 1745 g (3.8 lb). Multiply1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.
14、58on Exterior Insulation and Finish Systems (EIFS).Current edition approved April 10, 2003. Published June 2003.2Annual Book of ASTM Standards, Vol 04.11.3Annual Book of ASTM Standards, Vol 04.12.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Uni
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME22732003STANDARDTESTMETHODFORDETERMININGTHEDRAINAGEEFFICIENCYOFEXTERIORINSULATIONANDFINISHSYSTEMSEIFSCLADWALLASSEMBLIES

链接地址:http://www.mydoc123.com/p-530748.html