《ASTM E2271-2005a(2012)e1 Standard Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Dwellings and in Other Child-Occupied Facilities《住宅和其他儿童设施中随着铅危害.pdf》由会员分享,可在线阅读,更多相关《ASTM E2271-2005a(2012)e1 Standard Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Dwellings and in Other Child-Occupied Facilities《住宅和其他儿童设施中随着铅危害.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2271 05a (Reapproved 2012)1Standard Practice forClearance Examinations Following Lead Hazard ReductionActivities in Dwellings, and in Other Child-OccupiedFacilities1This standard is issued under the fixed designation E2271; the number immediately following the designation indicates the
2、 year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEFootnotes corrected editorially in April 2012.1. Scope1.1
3、This practice covers visual assessment for the presenceof deteriorated paint, surface dust, painted debris, and paintchips with environmental sampling of surface dust to deter-mine whether a lead hazard exists at the time of samplecollection, following lead-hazard reduction activities, or otherbuild
4、ing maintenance and modification activities.1.2 This practice addresses clearance examination of single-family detached dwellings (including exterior structures, suchas fences), multifamily dwellings having similar units, com-mon areas or exterior sites, and child-occupied facilities.1.3 This practi
5、ce also addresses clearance examinations thatmay include soil sampling, for example when soil abatementhas been performed.1.4 This practice includes a procedure for determiningwhether regulatory requirements for lead clearance levels fordust and, where warranted, soil have been met, and, conse-quent
6、ly whether a clearance area, passes or fails a clearanceexamination.NOTE 1This practice is based on that portion of “clearance” describedin 40 CFR Part 745 for abatement, and in 24 CFR 35 for lead-hazardreduction activities other than abatement, except that composite dustsampling is not used.1.5 The
7、 values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associate
8、d with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4840 Guide for Sample Chain-of-Custody ProceduresD5124 Practi
9、ce for Testing and Use of a Random NumberGenerator in Lumber and Wood Products SimulationE631 Terminology of Building ConstructionsE1480 Terminology of Facility Management (Building-Related)E1605 Terminology Relating to Lead in BuildingsE1727 Practice for Field Collection of Soil Samples forSubseque
10、nt Lead DeterminationE1728 Practice for Collection of Settled Dust SamplesUsing Wipe Sampling Methods for Subsequent LeadDeterminationE1792 Specification for Wipe Sampling Materials for Leadin Surface DustE2239 Practice for Record Keeping and Record Preserva-tion for Lead Hazard ActivitiesE2255 Prac
11、tice for Conducting Visual Assessments forLead Hazards in Buildings2.2 U.S. Regulations:324 CFR (Code of Federal Regulations) 35, Department ofHousing and Urban Development (HUD), Requirementsfor Notification, Evaluation and Reduction of Lead-BasedPaint Hazards in Federally Owned Residential Propert
12、yand Housing Receiving Federal Assistance (especiallysubparts B and R)1This practice is under the jurisdiction of ASTM Committee E06 on Perfor-mance of Buildings and is the direct responsibility of Subcommittee E06.23 on LeadHazards Associated with Buildings.Current edition approved April 1, 2012. P
13、ublished May 2012. Originallyapproved in 2003. Last previous edition approved in 2005 as E2271 05a. DOI:10.1520/E2271-05AR12E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume informatio
14、n, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov. Also available from http:/www.gpo.gov/fdsys/browse/collectionCfr.acti
15、on?collectionCode=CFR.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.40 CFR 745, Environmental Protection Agency (EPA),Lead-Based Paint Poisoning Prevention in Certain Resi-dential Structures (especially subparts D, L and Q)2.3 Gove
16、rnmental Agency Guidance:4,5EPA National Lead Laboratory Accreditation Program (NL-LAP)3. Terminology3.1 DefinitionsFor definitions of terms not appearinghere, see Terminologies E631, E1480, and E1605.3.2 Definitions of Terms Specific to This Standard:3.2.1 clearance area, nwork area and additional
17、spacesoutside the work area where lead contamination may haveoccurred during lead hazard reduction and other buildingmaintenance or modification activities.3.2.1.1 DiscussionThe spaces outside the work area mayinclude rooms connected to the work area, egress routes, wastestorage areas, and grounds a
18、djoining exterior work areas.3.2.2 work area, nthe interior or exterior space where leadhazard control or other building maintenance or modificationactivities are performed.3.2.2.1 DiscussionThe interior work space may include(1) a portion of a room, an entire room, or room equivalent, or(2) portion
19、s of multiple rooms, multiple rooms or roomequivalents, depending upon the extent or location, or both, ofthe lead hazard control activity. The exterior work space mayinclude (1) a portion of a building faade, an entire buildingfaade, associated structures, such as fences, and (2) bare soil.4. Signi
20、ficance and Use4.1 A clearance examination of abatement areas and otherareas associated with other lead-hazard control activities, orbuilding maintenance or modification activities in single-family detached dwellings, multifamily dwellings having simi-lar units, common areas or exterior sites, and c
21、hild-occupiedfacilities is performed to determine that the clearance area isadequately safe for reoccupancy.4.2 It is the responsibility of the user of this standard toassure that all regulatory, contractual, and personnel require-ments are met prior to conduct of a clearance examination. Ata minimu
22、m, users of this standard shall be trained in its use andin safe practices for its conduct.4.3 This practice is one of a set of standards developed forlead hazard management activities. The visual assessmentprocedures required in this standard are found in PracticeE2255 and the record keeping requir
23、ements are found inPractice E2239.4.4 Although this practice was primarily developed fordwellings and for other child-occupied facilities, this practicemay be also applied to nonresidential buildings and relatedstructures by agreement between the client and the individualconducting the clearance exa
24、mination.4.5 This practice may be used by owners and propertymanagers, including owner-occupants, and others responsiblefor maintaining facilities. It may also be used by lead hazardmanagement consultants, construction contractors, laborgroups, real estate and financial professionals, insurance orga
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME22712005A2012E1STANDARDPRACTICEFORCLEARANCEEXAMINATIONSFOLLOWINGLEADHAZARDREDUCTIONACTIVITIESINDWELLINGSANDINOTHERCHILDOCCUPIEDFACILITIES

链接地址:http://www.mydoc123.com/p-530747.html