ASTM E2271-2005a Standard Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Single-Family Dwellings and Child-Occupied Facilities《独院住宅和儿童设施中随着铅危害活性降.pdf
《ASTM E2271-2005a Standard Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Single-Family Dwellings and Child-Occupied Facilities《独院住宅和儿童设施中随着铅危害活性降.pdf》由会员分享,可在线阅读,更多相关《ASTM E2271-2005a Standard Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Single-Family Dwellings and Child-Occupied Facilities《独院住宅和儿童设施中随着铅危害活性降.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2271 05aStandard Practice forClearance Examinations Following Lead Hazard ReductionActivities in Dwellings, and in Other Child-OccupiedFacilities1This standard is issued under the fixed designation E 2271; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers visual assessment for the presenceof deteriora
3、ted paint, surface dust, painted debris, and paintchips with environmental sampling of surface dust to deter-mine whether a lead hazard exists at the time of samplecollection, following lead-hazard reduction activities, or otherbuilding maintenance and modification activities.1.2 This practice addre
4、sses clearance examination of single-family detached dwellings (including exterior structures, suchas fences), multifamily dwellings having similar units, com-mon areas or exterior sites, and child-occupied facilities.1.3 This practice also addresses clearance examinations thatmay include soil sampl
5、ing, for example when soil abatementhas been performed.1.4 This practice includes a procedure for determiningwhether regulatory requirements for lead clearance levels fordust and, where warranted, soil have been met, and, conse-quently whether a clearance area, passes or fails a clearanceexamination
6、.NOTE 1This practice is based on that portion of “clearance” describedin 40 CFR Part 745 for abatement, and in 24 CFR 35 for lead-hazardreduction activities other than abatement, except that composite dustsampling is not used.1.5 The values stated in SI units are to be regarded as thestandard.1.6 Th
7、is standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documen
8、ts2.1 ASTM Standards:2D 4840 Guide for Sampling Chain-of-Custody ProceduresD 5124 Practice for Testing and Use of a Random NumberGenerator in Lumber and Wood Products SimulationE 631 Terminology of Building ConstructionsE 1480 Terminology of Facility Management (Building-Related)E 1605 Terminology R
9、elating to Lead in BuildingsE 1727 Practice for Field Collection of Soil Samples forLead Determination by Atomic Spectrometry TechniquesE 1728 Practice for Field Collection of Settled DustSamples Using Wipe Sampling Methods for SubsequentLead DeterminationE 1792 Specification for Wipe Sampling Mater
10、ials for Leadin Surface DustE 2239 Practice for Record Keeping and Record Preserva-tion for Lead Hazard ActivitiesE 2255 Practice for Conducting Visual Assessments forLead Hazards in Buildings2.2 U.S. Regulations:324 CFR (Code of Federal Regulations) 35, Department ofHousing and Urban Development (H
11、UD), Requirementsfor Notification, Evaluation and Reduction of Lead-BasedPaint Hazards in Federally Owned Residential Propertyand Housing Receiving Federal Assistance (especiallysubparts B and R)40 CFR 745, Environmental Protection Agency (EPA),Lead-Based Paint Poisoning Prevention in Certain Resi-d
12、ential Structures (especially subparts D, L and Q)1This practice is under the jurisdiction of ASTM Committee E06 on Perfor-mance of Buildings and is the direct responsibility of Subcommittee E06.23 on LeadHazards Associated With Buildings.Current edition approved Oct. 1, 2005. Published October 2005
13、. Originallyapproved in 2003. Last previous edition approved in 2005 as E 2271 05.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary pag
14、e onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401. Also availablefrom http:/www.gpo.gov/nara/cfr/index.html.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken
15、, PA 19428-2959, United States.2.3 Governmental Agency Guidance:4,5EPA National Lead Laboratory Accreditation Program(NLLAP)3. Terminology3.1 DefinitionsFor definitions of terms not appearinghere, see Terminologies E 631, E 1480, and E 1605.3.2 Definitions of Terms Specific to This Standard:3.2.1 cl
16、earance area, nwork area and additional spacesoutside the work area where lead contamination may haveoccurred during lead hazard reduction and other buildingmaintenance or modification activities.3.2.1.1 DiscussionThe spaces outside the work area mayinclude rooms connected to the work area, egress r
17、outes, wastestorage areas, and grounds adjoining exterior work areas.3.2.2 work area, nthe interior or exterior space where leadhazard control or other building maintenance or modificationactivities are performed.3.2.2.1 DiscussionThe interior work space may include(1) a portion of a room, an entire
18、 room, or room equivalent, or(2) portions of multiple rooms, multiple rooms or roomequivalents, depending upon the extent or location, or both, ofthe lead hazard control activity. The exterior work space mayinclude (1) a portion of a building faade, an entire buildingfaade, associated structures, su
19、ch as fences, and (2) bare soil.4. Significance and Use4.1 A clearance examination of abatement areas and otherareas associated with other lead-hazard control activities, orbuilding maintenance or modification activities in single-family detached dwellings, multifamily dwellings having simi-lar unit
20、s, common areas or exterior sites, and child-occupiedfacilities is performed to determine that the clearance area isadequately safe for reoccupancy.4.2 It is the responsibility of the user of this standard toassure that all regulatory, contractual, and personnel require-ments are met prior to conduc
21、t of a clearance examination. Ata minimum, users of this standard shall be trained in its use andin safe practices for its conduct.4.3 This practice is one of a set of standards developed forlead hazard management activities. The visual assessmentprocedures required in this standard are found in Pra
22、cticeE 2255 and the record keeping requirements are found inPractice E 2239.4.4 Although this practice was primarily developed fordwellings and for other child-occupied facilities, this practicemay be also applied to nonresidential buildings and relatedstructures by agreement between the client and
23、the individualconducting the clearance examination.4.5 This practice may be used by owners and propertymanagers, including owner-occupants, and others responsiblefor maintaining facilities. It may also be used by lead hazardmanagement consultants, construction contractors, laborgroups, real estate a
24、nd financial professionals, insurance orga-nizations, legislators, regulators, and legal professionals.4.6 This standard does not address whether lead-hazardreduction activities or other building modification or mainte-nance work were done properly.5. General Requirements5.1 Applicable RegulationsTh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME22712005ASTANDARDPRACTICEFORCLEARANCEEXAMINATIONSFOLLOWINGLEADHAZARDREDUCTIONACTIVITIESINSINGLEFAMILYDWELLINGSANDCHILDOCCUPIEDFACILITIES

链接地址:http://www.mydoc123.com/p-530746.html