1、Designation: E 2270 05Standard Practice forPeriodic Inspection of Building Facades for UnsafeConditions1This standard is issued under the fixed designation E 2270; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This standard practice describes methods and proce-dures for inspection, evaluation, and reporting for periodicinspection of
3、 building facades for unsafe conditions. In thecontext of this standard, unsafe conditions are hazards causedby or resulting from loss of facade material.1.2 This standard practice does not purport to address thenature of deterioration of various building facade materials northe performance of their
4、 assemblies. It is the responsibility ofthe owner to retain a qualified professional who can demon-strate expertise in the evaluation of various facade materialsand their assemblies.1.3 Investigative techniques discussed may be intrusive,disruptive, or destructive. It is the responsibility of the qu
5、alifiedprofessional to anticipate, advise on the nature of procedures,and to plan for implementing repair as necessary.1.4 It is the responsibility of the specifying authority toestablish the usage of this standard practice and to supplementthis standard with additional requirements suitable to its
6、localjurisdiction. It is also the responsibility of the specifyingauthority to determine compliance with local licensing regula-tions and customary practices.1.5 This standard may involve hazardous materials, opera-tions, and equipment. This standard does not purport toaddress all of the safety conc
7、erns, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.Awareness of safety and familiarity with safe procedures areparticularly important f
8、or above-ground operations on facadesand destructive investigative procedures, which typically areassociated with the work described.2. Referenced Documents2.1 ASTM Standards:2E 631 Terminology of Building Constructions3. Terminology3.1 Refer to Terminology E 631.3.2 Definitions:3.2.1 facadeall area
9、s on the exterior of the building,except for horizontal roof areas. The facade includes allexterior walls, windows, balconies, cornices, parapets, andappurtenances. The facade also includes walls supported atroof level, such as penthouse walls, chimneys, and so forth.3.2.2 public access areaany side
10、walk, street, alley, park,plaza, playground, schoolyard or other area that is open andaccessible to the public, regardless of whether it is publicly orprivately owned.3.2.3 qualified professionalan architect or civil/structuralengineer duly licensed. The qualified professional must beknowledgeable o
11、f the design, construction, and inspection ofbuilding facades, stability, and deterioration mechanisms relat-ing to the specific materials and assemblies particular to thefacade being inspected.3.2.4 qualified inspectora qualified professional or a per-son working under the direct supervision of a q
12、ualifiedprofessional.3.2.5 maintenance personnelpersonnel who have beeninvolved in maintenance of the subject building facades.3.2.6 ownerthe owner, agent, manager, or person incharge, of possession, operation, or management of the build-ing, or any combination thereof.3.2.7 specifying authoritypart
13、y requiring inspection of abuilding facade.NOTE 1The specifiying authority may be a governmental body.3.2.8 levels of facade inspections:1This practice is under the jurisdiction of ASTM Committee E06 on Perfor-mance of Buildings and is the direct responsibility of Subcommittee E06.55 onExterior Buil
14、ding Wall Systems.Current edition approved Mar. 1, 2005. Published March 2005. Originallyapproved in 2003. Last previous edition approved in 2003 as E 2270 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of
15、ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.8.1 general inspectionvisual observation of facadecomponents from distances equal t
16、o or greater than 6 ft (1.8 m)with or without magnification or remote optical devices.3.2.8.2 detailed inspectionvisual observation from lessthan 6 ft (1.8 m) and tactile evaluation of facade components,including probing and non-destructive testing to observe con-cealed conditions of wall constructi
17、on.3.2.9 probedisassembly/removal of selective portions of afacade to observe concealed conditions of wall construction.3.2.10 non-destructive testing (NDT)a test that causes nosignificant structural damage to building components.3.2.11 facade agenumber of years since the originalCertificate of Occu
18、pancy for building was issued, or sinceentire facade replacement.3.2.12 watertight integritythe means a facade employs toprevent water intrusion to areas or materials where waterintrusion is not intended.3.2.13 categories of facade conditions:3.2.13.1 unsafe conditiona condition identified at the ti
19、meof inspection of a component or system that presents animminent threat of harm, injury, damage, or loss to persons orproperty.3.2.13.2 requires repair/stabilizationa condition identi-fied at the time of inspection that shall be repaired or stabilizedin order to prevent progression into an “unsafe
20、condition” priorto the next scheduled inspection.NOTE 2The immediacy of actions to address conditions requiringrepair other than unsafe conditions is highly variable and should bedetermined by the owner. Such determination may require more detailedinvestigation than addressed herein to assess the ur
21、gency of such action.3.2.13.3 ordinary maintenancea condition identified atthe time of inspection that is not characterized as an “unsafecondition” or “requires repair/stabilization,” but requires main-tenance.3.2.14 facade inspection reporta detailed documentationof qualified professionals findings
22、, observations, discussions,conclusions, and recommendations about the subject buildingfacades.3.2.15 facade inspection categorycategory assigned tobuilding facade based on the facade material, construction, age,and inspection level/extent required, as outlined in Annex A1of this document.4. Signifi
23、cance and Use4.1 IntentThis standard practice is intended to establishthe minimum requirements for conducting periodic inspectionsof building facades to identify unsafe conditions that couldcause harm to persons and property. It addresses the requiredcontent of the facade inspection to convey to the
24、 specifyingauthority the condition of the facade and allow comparisons offacade conditions at other times. Facade Inspection reportsconducted and prepared as outlined in this standard practicewill provide specifying authorities the information necessary tomitigate the threat of harm, injury, damage,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME22702005STANDARDPRACTICEFORPERIODICINSPECTIONOFBUILDINGFACADESFORUNSAFECONDITIONS 不安全 条件下 建筑物 正面

链接地址:http://www.mydoc123.com/p-530742.html