ASTM E2265-2007 Standard Terminology for Anchors and Fasteners in Concrete and Masonry《混凝土和砖石工程用锚和紧固件的标准术语》.pdf
《ASTM E2265-2007 Standard Terminology for Anchors and Fasteners in Concrete and Masonry《混凝土和砖石工程用锚和紧固件的标准术语》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2265-2007 Standard Terminology for Anchors and Fasteners in Concrete and Masonry《混凝土和砖石工程用锚和紧固件的标准术语》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2265 07Standard Terminology forAnchors and Fasteners in Concrete and Masonry1This standard is issued under the fixed designation E 2265; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A nu
2、mber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This terminology covers standard terminology for an-chors and fasteners installed in structural members made ofconcrete or masonry.1.2 T
3、his terminology does not cover terms relating to themechanical properties of the materials used for fabricatinganchors, nor does it cover their use.1.3 The terms are listed alphabetically. Compound termsappear in the natural spoken order.2. Referenced Documents2.1 ASTM Standards:2E 488 Test Methods
4、for Strength of Anchors in Concreteand Masonry ElementsE 631 Terminology of Building ConstructionsE 1190 Test Methods for Strength of Power-Actuated Fas-teners Installed in Structural MembersE 1512 Test Methods for Testing Bond Performance ofBonded Anchors3. Terminologyadhesive-bonded anchoranchor p
5、laced into a hole in thebase material, and which derives its holding strength from achemical adhesive placed between the wall of the hole in thebase material and the embedded portion of the anchor.allowable loadcapacity assigned to an anchor in accordancewith allowable-stress design procedures.ancho
6、rcast-in-place or post-installed fastening device in-stalled in the base material for the purpose of transferringloads to the base material.anchor loading: axialload applied concentrically with theanchor longitudinal axis.anchor loading: bendingflexure induced in the anchor byapplication of a shear
7、load at a distance from the surface ofthe base material.anchor loading: combinedaxial and shear loading appliedsimultaneously (oblique loading).anchor loading: shearload applied parallel to the surface ofthe base material and perpendicular to the anchors longitu-dinal axis.anchor spacingdistance bet
8、ween anchors measured center-line to centerline.attachmentstructural element (fixture) external to the sur-face of the base material, and which transmits loads to theanchor.base materialmaterial in which anchor is installed, such asconcrete or masonry.bond failurefailure mode characterized by loss o
9、f bondeither between the anchor and adhesive or between theadhesive and the base material.cast-in-place anchoranchor installed in formwork prior toplacement of concrete.characteristic valuethe 5 % fractile (value with a 95 %probability of being exceeded, with a confidence of 90 %).clamping forcecomp
10、ression force transmitted to the basematerial as a result of preload in the anchor.concrete breakout failureanchor failure mode character-ized by concrete cone failure or concrete edge failure.connectionattachment of load-bearing element to concreteor masonry base materials using anchors.cracked con
11、cretefor testing purposes, a test member havingone or more cracks, each of which is approximately uniformin width through the depth of the member.DISCUSSIONOnly one crack is permitted in the area of influence ofthe test anchor.critical edge distanceminimum anchor edge distance, mea-sured from the an
12、chor centerline to the edge of the structuralmember, at which the full anchor capacity can be obtainedwithout concrete edge breakout failure or splitting failure.critical spacingminimum anchor spacing, measured center-line to centerline of the anchors, at which the full anchorcapacity can be obtaine
13、d without influence from adjacentanchors.cure timethe length of time required for a grouted anchor oran adhesive-bonded anchor to develop its specified strength.1This terminology is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommitt
14、ee E06.13on Structural Performance of Connections in Building Construction.Current edition approved April 1, 2007. Published May 2007. Originallyapproved in 2003. Last previous approved in 2006 as E 2265 06b.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custome
15、r Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.diamond core bitnon-percussion drill b
16、it, usually utilizing ahollow cylindrical pipe or tube with a diamond-impregnatedmatrix at the end that is used to drill in the base material.displacementmovement of anchor relative to the structuralmember.DISCUSSION For tension tests, displacement is measured parallel tothe anchor axis; for shear t
17、ests, displacement is measured perpendicularto the anchor axis.displacement-controlled expansion anchora post-installedanchor that derives its holding strength by expansion againstthe side of the drilled hole through movement of an internalplug in the sleeve or through movement of the sleeve over an
18、expansion element (plug), Once set, the anchor does notexpand further under load.drillelectric-, hydraulic-, or air-powered tool for boringholes into the base material, using rotary action, oftensupplemented by percussion or hammering.drill bitsolid-shaft, carbide-tipped bit, usually with spiralflut
19、es, used to drill holes in the base material.edge distanceperpendicular distance from the centerline ofthe anchor to the edge of the structural member in whichanchor is installed.effective embedment depththe overall depth through whichthe anchor transfers force to or from the surrounding basemateria
20、l, measured from the surface: for adhesive-bondedanchors measured to the deepest point of the anchor; forcast-in-place anchors measured to the upper surface of thedirect bearing element; for undercut and sleeve anchorsmeasured to the bottom of the expansion mechanism; forexpansion anchors measured t
21、o the farthest point of contactbetween the expansion mechanism and surrounding mate-rial.elongationincrease in length of the anchor under loadingresulting from axial strain of the anchor material.embedment depthdistance measured from the surface of thebase material to the farthest point of anchor, m
22、easured priorto setting of anchor.expansion anchorpost-installed anchor that derives its ca-pacity predominately from frictional forces generated bymechanical expansion of the anchor against sides of hole.expansion sleeveouter part of expansion anchor, which isforced outward by its center part as a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME22652007STANDARDTERMINOLOGYFORANCHORSANDFASTENERSINCONCRETEANDMASONRY 混凝土 砖石 工程 紧固 标准 术语 PDF

链接地址:http://www.mydoc123.com/p-530731.html