ASTM E2254-2009 Standard Test Method for Storage Modulus Calibration of Dynamic Mechanical Analyzers《动态机械分析器的储能模量的标准试验方法》.pdf
《ASTM E2254-2009 Standard Test Method for Storage Modulus Calibration of Dynamic Mechanical Analyzers《动态机械分析器的储能模量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2254-2009 Standard Test Method for Storage Modulus Calibration of Dynamic Mechanical Analyzers《动态机械分析器的储能模量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2254 09Standard Test Method forStorage Modulus Calibration of Dynamic MechanicalAnalyzers1This standard is issued under the fixed designation E2254; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the calibration or perfor-mance confirmation for the storage modulus scale of a com-mercial or cust
3、om built dynamic mechanical analyzer (DMA)over the temperature range of -100 to 300 C using referencematerials in the range of 1 to 200 GPa.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport t
4、o address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E473 Ter
5、minology Relating to Thermal Analysis and Rhe-ologyE1142 Terminology Relating to Thermophysical Properties3. Terminology3.1 DefinitionsSpecific technical terms used in this testmethod are defined in Terminologies E473 and E1142.4. Summary of Test Method4.1 The storage modulus signal determined by a
6、dynamicmechanical analyzer for an elastic reference material is com-pared to the reported storage modulus for that referencematerial. A linear relationship is used to correlate the experi-mental storage modulus signal with the reported value of thereference material.4.2 The mode of deformation (for
7、example, tensile, flexure,compression, etc.) shall be reported.5. Significance and Use5.1 This test method calibrates or demonstrates conformityof a dynamic mechanical analyzer at an isothermal temperaturewithin the range of -100 to 300 C.5.2 Dynamic mechanical analysis experiments often usetemperat
8、ure ramps. This method does not address the effect ofthat change in temperature on the storage modulus.5.3 A calibration factor may be required to obtain correctedstorage modulus values.5.4 This method may be used in research and development,specification acceptance, and quality control or assurance
9、.6. Apparatus6.1 The essential instrumentation required to provide theminimum dynamic mechanical capability for this test methodincludes:6.1.1 Drive Motor, to apply force (or displacement) to thespecimen in a periodic manner. This motor may also be capableof providing static force or displacement on
10、 the specimen.6.1.2 Coupling Shaft, or other means to transmit the forcefrom the motor to the specimen.6.1.3 Clamping System(s), to fix the specimen between thedrive shaft and the stationary clamp(s).6.1.4 Position Sensor, to measure the change in position ofthe specimen during dynamic motion, or,6.
11、1.5 Force Sensor, to measure the force applied to thespecimen.6.1.6 Temperature Sensor, to provide an indication of thespecimen temperature to 6 1 C.6.1.7 Furnace, to provide controlled heating or cooling of aspecimen at a constant temperature or at a constant rate withinthe applicable temperature r
12、ange of -100 to +300 C.6.1.8 Temperature Controller, capable of executing a spe-cific temperature program by operating the furnace between-100 and +300 C.6.1.9 A Data Collection Device, to provide a means ofacquiring, storing and displaying measured or calculated sig-nals, or both. The minimum outpu
13、t signals required are storagemodulus, loss modulus, tangent delta, temperature and time.1This test method is under the jurisdiction ofASTM Committee E37 on ThermalMeasurements and is the direct responsibility of Subcommittee E37.10 on Funda-mental, Statistical and Mechanical Properties.Current edit
14、ion approved Sept. 1, 2009. Published January 2010. Originalapproved in 2003. Last previous edition approved in 2008 as E225408. DOI:10.1520/E2254-09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStand
15、ards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.2 Auxiliary instrumentation considered necessary in con-ducting this method near or below ambi
16、ent room temperature.6.2.1 Cooling capability to sustain a constant temperatureat or below ambient room temperature or to provide controlledcooling.6.3 Micrometer, calipers or other length measuring devicecapable of measuring length of 1.0 to 100 mm with a precisionof 6 0.01 mm.7. Reagents and Mater
17、ials7.1 A reference material of known storage modulus, formedto the shape suitable for characterization by the particulardynamic mechanical analyzer (see Table 1).NOTE 1The storage modulus of the calibration materials used in thisstandard is often similar to that of the construction materials of the
18、 testapparatus. Thus the examination of high modulus materials may result ininstrument compliance during testing. The test apparatus calibrationprocedure (see 9.1) should include a compliance correction. The user ofthis standard shall verify whether or not such compliance corrections areincluded pri
19、or to its use.8. Sampling8.1 Test specimens are typically prepared in the form of arectangular test bars or film strips.NOTE 2It is common practice to bevel or “break” edges of machinedparts. This practice shall not be followed in the preparation of testspecimens for this method. The measured storag
20、e modulus of such testspecimens reads low due to imperfect sample geometry.9. Calibration and Standardization9.1 Perform any storage modulus signal calibration proce-dures recommended by the manufacturer of the dynamicmechanical analyzer as described in the operations manual.10. Procedure10.1 Prepar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME22542009STANDARDTESTMETHODFORSTORAGEMODULUSCALIBRATIONOFDYNAMICMECHANICALANALYZERS 动态 机械 分析器 储能模量

链接地址:http://www.mydoc123.com/p-530696.html