ASTM E2067-2003 Standard Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests《最大氧消耗量热法火灾试验的标准实施规程》.pdf
《ASTM E2067-2003 Standard Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests《最大氧消耗量热法火灾试验的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2067-2003 Standard Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests《最大氧消耗量热法火灾试验的标准实施规程》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2067 03An American National StandardStandard Practice forFull-Scale Oxygen Consumption Calorimetry Fire Tests1This standard is issued under the fixed designation E 2067; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice deals with methods to construct, calibrate,and use full scale oxygen consumption calorime
3、ters to helpminimize testing result discrepancies between laboratories.1.2 The methodology described herein is used in a numberof ASTM test methods, in a variety of unstandardized testmethods, and for research purposes. This practice will facilitatecoordination of generic requirements, which are not
4、 specific tothe item under test.1.3 The principal fire-test-response characteristics obtainedfrom the test methods using this technique are those associatedwith heat release from the specimens tested, as a function oftime. Other fire-test-response characteristics also are deter-mined.1.4 This practi
5、ce is intended to apply to the conduction ofdifferent types of tests, including both some in which theobjective is to assess the comparative fire performance ofproducts releasing low amounts of heat or smoke and some inwhich the objective is to assess whether flashover will occur.1.5 This practice d
6、oes not provide pass/fail criteria that canbe used as a regulatory tool, nor does it describe a test methodfor any material or product.1.6 For use of the SI system of units in referee decisions, seeIEEE/ASTM SI-10. The units given in parentheses are pro-vided for information only.1.7 This standard i
7、s used to measure and describe theresponse of materials, products, or assemblies to heat and flameunder controlled conditions, but does not by itself incorporateall factors required for fire hazard or fire risk assessment of thematerials, products, or assemblies under actual fire conditions.NOTE 1Th
8、is is the standard caveat described in section F2.2.2.1 of theForm and Style for ASTM Standards manual for fire-test-responsestandards. In actual fact, this practice does not provide quantitativemeasures.1.8 Fire testing of products and materials is inherentlyhazardous, and adequate safeguards for p
9、ersonnel and propertyshall be employed in conducting these tests. Fire testinginvolves hazardous materials, operations, and equipment. Seealso Section 7.1.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of th
10、is standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 5424 Test Method for Smoke Obscuration of InsulatingMaterials Contained in Electrical or Optical Fiber CablesWhen Bur
11、ning in a Vertical Cable Tray ConfigurationD 5537 Test Method for Heat Release, Flame Spread andMass Loss Testing of Insulating Materials Contained inElectrical or Optical Fiber Cables When Burning in aVertical Cable Tray ConfigurationD6113 Test Method for Using a Cone Calorimeter toDetermine Fire-T
12、est-Response Characteristics of Insulat-ing Materials Contained in Electrical or Optical FiberCablesE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE 176 Terminology of Fire StandardsE 603 Guide for Room Fire ExperimentsE 662 Test Method for Specific Optical Density of SmokeG
13、enerated by Solid MaterialsE 906 Test Method for Heat and Visible Smoke ReleaseRates for Materials and ProductsE 1354 Test Method for Heat and Visible Smoke ReleaseRates for Materials and Products Using an Oxygen Con-sumption CalorimeterE 1474 Test Method for Determining the Heat Release Rateof Upho
14、lstered Furniture and Mattress Components orComposites Using a Bench Scale Oxygen ConsumptionCalorimeter1This practice is under the jurisdiction of ASTM Committee E05 on FireStandards and is the direct responsibility of Subcommittee E05.13 on Large ScaleFire Tests.Current edition approved Oct. 1, 20
15、03. Published November 2003. Originallyapproved in 2000. Last previous edition approved in 2002 as E 206702.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the stan
16、dards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.E 1537 Test Method for Fire Testing of Upholstered Furni-tureE 1590 Test Method for Fire Testing of MattressesE 1623 Test Method for Deter
17、mination of Fire and ThermalParameters of Materials, Products and Systems Using andIntermediate Scale Calorimeter (ICAL)E 1740 Test Method for Determining the Heat Release Rateand Other Fire-Test-Response Characteristics of Wallcov-ering Composites Using a Cone CalorimeterE 1822 Test Method for Fire
18、 Testing of Stacked ChairsIEEE/ASTM SI-10, International System of Units (SI) TheModernized Metric System2.2 ISO Standards:3ISO 13943 Fire Safety-VocabularyISO 5660-1, Fire TestsReaction to FireRate of HeatRelease from Building Products (Cone CalorimeterMethod)ISO 9705, Fire Tests - Full-Scale Room
19、Test for SurfaceProducts2.3 California Bureau of Home Furnishings and ThermalInsulation Standards:4CA Technical Bulletin 129 (October 1992), FlammabilityTest Procedure for Mattresses for Use in Public BuildingsCA Technical Bulletin 133 (January 1991), FlammabilityTest Procedure for Seating Furniture
20、 for Use in PublicOccupancies2.4 NFPA Standards:5NFPA 265 Standard Methods of Fire Tests for EvaluatingRoom Fire Growth Contribution of Textile Wall CoveringsNFPA 266 Standard Method of Test for Fire Characteristicsof Upholstered Furniture Exposed to Flaming IgnitionSourceNFPA 267 Standard Method of
21、 Test for Fire Characteristicsof Mattresses and Bedding Assemblies Exposed to Flam-ing Ignition SourceNFPA 286 Standard Methods of Fire Tests for EvaluatingRoom Fire Growth Contribution of Wall and CeilingInterior Finish2.5 UL Standards:6UL 1685, Standard Vertical Tray Fire Propagation andSmoke Rele
22、ase Test for Electrical and Optical FiberCablesUL 1975, Standard Fire Tests for Foamed Plastics Used forDecorative Purposes3. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, refer to Terminology E 176 and ISO 13943. In case ofconflict, the definitions given in Terminology
23、E 176 shallprevail.3.1.1 heat release rate, nthe heat evolved from thespecimen, per unit of time. (E 176)3.1.2 ignition, nthe initiation of combustion. (E 176)3.1.2.1 DiscussionThe combustion may be evidenced byglow, flame, detonation or explosion. The combustion may besustained or transient.3.1.3 o
24、xygen consumption principle, nthe expression ofthe relationship between the mass of oxygen consumed duringcombustion and the heat released. (E 176)3.1.4 smoke, nthe airborne solid and liquid particulatesand gases evolved when a material undergoes pyrolysis orcombustion. (E 176)3.1.5 smoke obscuratio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME20672003STANDARDPRACTICEFORFULLSCALEOXYGENCONSUMPTIONCALORIMETRYFIRETESTS 最大 消耗量 火灾 试验 标准 实施 规程

链接地址:http://www.mydoc123.com/p-530192.html