《ASTM E2058-2006 Standard Test Methods for Measurement of Synthetic Polymer Material Flammability Using a Fire Propagation Apparatus (FPA)《用火焰蔓延仪(FPA)测量合成聚合物材料易燃性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2058-2006 Standard Test Methods for Measurement of Synthetic Polymer Material Flammability Using a Fire Propagation Apparatus (FPA)《用火焰蔓延仪(FPA)测量合成聚合物材料易燃性的标准试验方法》.pdf(31页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2058 06An American National StandardStandard Test Methods forMeasurement of Synthetic Polymer Material FlammabilityUsing a Fire Propagation Apparatus (FPA)1This standard is issued under the fixed designation E 2058; the number immediately following the designation indicates the year o
2、foriginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This fire-test-response standard determines and quanti-fi
3、es synthetic polymer material flammability characteristics,related to the propensity of materials to support fire propaga-tion, by means of a fire propagation apparatus (FPA). Materialflammability characteristics that are quantified include time toignition (tign), chemical ( Qchem), and convective (
4、 Qc) heatrelease rates, mass loss rate ( m) and effective heat ofcombustion (EHC).1.2 The following test methods, capable of being performedseparately and independently, are included herein:1.2.1 Ignition Test, to determine tignfor a horizontal speci-men;1.2.2 Combustion Test, to determine Qchem, Qc
5、, m, and EHCfrom burning of a horizontal specimen; and,1.2.3 Fire Propagation Test, to determine Qchemfrom burn-ing of a vertical specimen.1.3 Distinguishing features of the FPA include tungsten-quartz external, isolated heaters to provide a radiant flux of upto 65 kW/m2to the test specimen, which r
6、emains constantwhether the surface regresses or expands; provision for com-bustion or upward fire propagation in prescribed flows ofnormal air, air enriched with up to 40 % oxygen, air oxygenvitiated, pure nitrogen or mixtures of gaseous suppressionagents with the preceding air mixtures; and, the ca
7、pability ofmeasuring heat release rates and exhaust product flows gener-ated during upward fire propagation on a vertical test specimen0.305 m high.1.4 The FPA is used to evaluate the flammability of syn-thetic polymer materials and products. It is also designed toobtain the transient response of su
8、ch materials and products toprescribed heat fluxes in specified inert or oxidizing environ-ments and to obtain laboratory measurements of generationrates of fire products (CO2, CO, and, if desired, gaseoushydrocarbons) for use in fire safety engineering.1.5 Ignition of the specimen is by means of a
9、pilot flame ata prescribed location with respect to the specimen surface.1.6 The Fire Propagation test of vertical specimens is notsuitable for materials that, on heating, melt sufficiently to forma liquid pool.1.7 Values stated are in SI units. Values in parentheses arefor information only.1.8 This
10、 standard is used to measure and describe theresponse of materials, products, or assemblies to heat and flameunder controlled conditions, but does not by itself incorporateall factors required for fire hazard or fire risk assessment of thematerials, products or assemblies under actual fire condition
11、s.1.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific
12、 hazardstatements, see Section 7.2. Referenced Documents2.1 ASTM Standards:2E 176 Terminology of Fire StandardsE 906 Test Method for Heat and Visible Smoke ReleaseRates for Materials and ProductsE 1321 Test Method for Determining Material Ignition andFlame Spread PropertiesE 1354 Test Method for Hea
13、t and Visible Smoke ReleaseRates for Materials and Products Using an Oxygen Con-sumption CalorimeterE 1623 Test Method for Determination of Fire and ThermalParameters of Materials, Products, and Systems Using anIntermediate Scale Calorimeter (ICAL)3. Terminology3.1 DefinitionsFor definitions of term
14、s used in these testmethods, refer to Terminology E 176.3.2 Definitions of Terms Specific to This Standard:3.2.1 fire propagation, nincrease in the exposed surfacearea of the specimen that is actively involved in flamingcombustion.1These test methods are under the jurisdiction ofASTM Committee E05 o
15、n FireStandards and are the direct responsibility of Subcommittee E05.22 on SurfaceBurning.Current edition approved Oct. 1, 2006. Published November 2006. Originallyapproved in 2000. Last previous edition approved in 2003 as E 2058 03.2For referenced ASTM standards, visit the ASTM website, www.astm.
16、org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.3 Symbols
17、:Ad= cross sectional area of test section duct (m2)cp= specific heat of air at constant pressure (kJ/kg K)Gco= mass flow rate of CO in test section duct (kg/s)Gco2= mass flow rate of CO2in test section duct (kg/s)DHeff= effective heat of combustion (kJ/kg)K = flow coefficient of averaging Pitot tube
18、 duct gasvelocity/(2Dpm/r)1/2 (-)Mloss= ultimate change in specimen mass resulting fromcombustion (kg)m = mass loss rate of test specimen (kg/s)md= mass flow rate of gaseous mixture in test sectionduct (kg/s)Patm= atmospheric pressure (Pa)Dpm= pressure differential across averaging Pitot tube intest
19、 section duct (Pa)Q = cumulative heat released during Combustion Test(kJ)Qchem= chemical heat release rate (kW)Qc= convective heat release rate (kW)Ta= gas temperature in test section duct before igni-tion (K)Td= gas temperature in test section duct (K)t = time (s)tign= ignition time (s)Dt = time be
20、tween data scans (s)XCO2= measured carbon dioxide analyzer reading ormole fraction of carbon dioxide (-)XCO= measured carbon monoxide analyzer reading ormole fraction of CO (-)3.4 Superscripts:= per unit time (s1)0= before ignition of the specimen3.5 Subscripts:d= test section ductj= fire product4.
21、Summary of Test Method4.1 Three separate test methods are composed herein, andare used independently in conjunction with a Fire PropagationApparatus. The Ignition and Combustion test methods involvethe use of horizontal specimens subjected to a controlled,external radiant heat flux, which can be set
22、 from 0 up to 65kW/m2. The Fire Propagation test method involves the use ofvertical specimens subjected to ignition near the base of thespecimen from an external radiant heat flux and a pilot flame.Both the Combustion and Fire Propagation test methods can beperformed using an inlet air supply that i
23、s either normal air orother gaseous mixtures, such as air with added nitrogen or airenriched with up to 40 % oxygen.4.2 The Ignition test method is used to determine the timerequired for ignition, tign, of horizontal specimens by a pilotflame as a function of the magnitude of a constant, externallya
24、pplied radiant heat flux. Measurements also are made of timerequired until initial fuel vaporization. The surface of thesespecimens is coated with a thin layer of black paint to ensurecomplete absorption of the radiant heat flux from the infraredheating system (note that the coating does not itself
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME20582006STANDARDTESTMETHODSFORMEASUREMENTOFSYNTHETICPOLYMERMATERIALFLAMMABILITYUSINGAFIREPROPAGATIONAPPARATUSFPA

链接地址:http://www.mydoc123.com/p-530162.html