1、Designation: E 2046 08Standard Test Method forReaction Induction Time by Thermal Analysis1This standard is issued under the fixed designation E 2046; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numb
2、er in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the measurement of ReactionInduction Time (RIT) of chemical materials that undergoexothermic reactions with an i
3、nduction period. The techniquesand apparatus described may be used for solids, liquids, orslurries of chemical substances. The temperature range coveredby this test method is typically from ambient to 400C. Thisrange may be extended depending upon the apparatus used.1.2 The RIT is a relative index v
4、alue, not an absolutethermodynamic property.As an index value, the RIT value maychange depending upon experimental conditions. A compari-son of RIT values may be made only for materials tested undersimilar conditions of apparatus, specimen size, and so forth.Furthermore, the RIT value may not predic
5、t behavior of largequantities of material.1.3 The RIT shall not be used by itself to establish a safeoperating temperature. It may be used in conjunction withother test methods (for example, E 487, E 537, and E 1981) aspart of a hazard analysis of a particular operation.1.4 This test method may be u
6、sed for RIT values greaterthan 15 min (as relative imprecision increases at shorterperiods).1.5 This test method is used to study catalytic and autocata-lytic reactions. These reactions depend upon time as well astemperature. Such reactions are often studied by fixing oneexperimental parameter (that
7、 is, time or temperature) and thenmeasuring the other parameter (that is, temperature or time).This test method measures time to reaction onset detectionunder isothermal conditions. It is related to Test Method E 487that measures detected reaction onset temperature under con-stant time conditions1.6
8、 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.7 There is no ISO standard equivalent to this test method.1.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresp
9、onsibility of the user of this standard to consult andestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 3350 Specification for Polyethylene Plastics Pipe andFittings MaterialsD 3895 T
10、est Method for Oxidative-Induction Time of Poly-olefins by Differential Scanning CalorimetryD 4565 Test Methods for Physical and Environmental Per-formance Properties of Insulations and Jackets for Tele-communications Wire and CableD 5483 Test Method for Oxidation Induction Time of Lu-bricating Grea
11、ses by Pressure Differential Scanning Calo-rimetryD 6186 Test Method for Oxidation Induction Time of Lu-bricating Oils by Pressure Differential Scanning Calorim-etry (PDSC)E 473 Terminology Relating to Thermal Analysis and Rhe-ologyE 487 Test Method for Constant-Temperature Stability OfChemical Mate
12、rialsE 537 Test Method for The Thermal Stability Of ChemicalsBy Differential Scanning CalorimetryE 967 Test Method for Temperature Calibration of Differ-ential Scanning Calorimeters and Differential ThermalAnalyzersE 968 Practice for Heat Flow Calibration of DifferentialScanning CalorimetersE 1445 T
13、erminology Relating to Hazard Potential ofChemicalsE 1858 Test Method for Determining Oxidation InductionTime of Hydrocarbons by Differential Scanning Calorim-etryE 1860 Test Method for Elapsed Time Calibration of Ther-mal AnalyzersE 1981 Guide for Assessing Thermal Stability of Materialsby Methods
14、of Accelerating Rate CalorimetryE 2070 Test Method for Kinetic Parameters by Differential1This test method is under the jurisdiction of ASTM Committee E27 on HazardPotential of Chemicals and is the direct responsibility of Subcommittee E27.02 onThermal Stability and Condensed Phases.Current edition
15、approved April 1, 2008. Published May 2008. Originallyapproved in 1999. Last previous edition approved in 2003 as E 2046 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, r
16、efer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Scanning Calorimetry Using Isothermal Methods3. Terminology3.1 The specialized terms used in this test method aredescribed
17、 in Terminologies E 473 and E 1445.3.2 Definitions of Terms Specific to This Standard:3.2.1 constant temperature stability (CTS) value, nthemaximum temperature at which a chemical compound ormixture may be held for a minimum of two hours withoutexhibiting a measurable exothermic reaction. (See Test
18、MethodE 487.)3.2.2 reaction induction time (RIT) value, nthe time achemical compound or mixture may be held under isothermalconditions until it exhibits a specified exothermic reaction.4. Summary of Test Method4.1 A specimen of the chemical compound or mixture isplaced in an inert container that is
19、then heated to an operator-selected test temperature of interest. The specimen temperatureand the difference in heat flow or temperature between the testspecimen and an inert reference are monitored until an exo-thermic reaction is recorded. The time from the attainment ofthe isothermal test tempera
20、ture until the extrapolated onset tothe exothermic reaction is taken as the Reaction InductionTime.4.2 Using fresh specimens measurements at more than oneisothermal test temperature may be made.4.3 The RIT is expressed as time at a specific test tempera-ture. For example:RIT = 120 min at 100 C5. Sig
21、nificance and Use5.1 This test method measures the time to extrapolated onsetof an exothermic reaction under constant temperature (isother-mal) conditions for reactions which have an induction period,for example, those which are catalytic or autocatalytic in natureor which contain reaction inhibitor
22、s.5.2 The RIT determined by this test method is an indexmeasurement that is useful for comparing one material toanother at the test temperature of interest and in the sameapparatus type only.5.3 This test method is a useful adjunct to dynamic thermaltests, such as Test Method E 537, which are perfor
23、med underconditions in which the sample temperature is increasedcontinuously at constant rate. Results obtained under dynamictest conditions may result in higher estimates of temperature atwhich an exothermic reaction initiates because the detectedonset temperature is dependent upon the heating rate
24、 andbecause dynamic methods allow insufficient time for autocata-lytic reactions to measurably affect the onset temperature.5.4 RIT values determined under a series of isothermal testconditions may be plotted as their logarithm versus thereciprocal of the absolute temperature to produce a plot, thes
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME20462008STANDARDTESTMETHODFORREACTIONINDUCTIONTIMEBYTHERMALANALYSIS 分析 测定 感应 反应时间 标准 方法 PDF

链接地址:http://www.mydoc123.com/p-530145.html