ASTM E2040-2003 Standard Test Method for Mass Scale Calibration of Thermogravimetric Analyzers《热重分析仪质量刻度校准的标准试验方法》.pdf
《ASTM E2040-2003 Standard Test Method for Mass Scale Calibration of Thermogravimetric Analyzers《热重分析仪质量刻度校准的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2040-2003 Standard Test Method for Mass Scale Calibration of Thermogravimetric Analyzers《热重分析仪质量刻度校准的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2040 03Standard Test Method forMass Scale Calibration of Thermogravimetric Analyzers1This standard is issued under the fixed designation E 2040; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the calibration or perfor-mance confirmation of the mass (or weight) scale of thermo-gravimetric anal
3、yzers and is applicable to commercial andcustom-built apparatus.1.2 Electronic instrumentation or automated data analysisand reduction systems or treatments equivalent to this testmethod may be used.1.3 SI units are the standard.1.4 There is no ISO standard equivalent to this test method.1.5 This st
4、andard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1
5、 ASTM Standards:2E 473 Terminology Relating to Thermal AnalysisE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 1142 Terminology Relating to Thermophysical Properties3. Terminology3.1 DefinitionsSpecific technical terms used in this testmethod are de
6、fined in Terminologies E 473 and E 1142.4. Summary of Test Method4.1 The mass signal generated by a thermogravimetricanalyzer is compared to the mass of a reference materialtraceable to a national reference laboratory. A linear correlationusing two calibration points is used to relate the mass (orwe
7、ight) signal generated by the thermogravimetric analyzerand that of the reference material.5. Significance and Use5.1 This test method calibrates or demonstrates conformityof thermogravimetric apparatus at ambient conditions. Mostthermogravimetry analysis experiments are carried out undertemperature
8、 ramp conditions or at isothermal temperaturesdistant from ambient conditions. This test method does notaddress the temperature effects on mass calibration.5.2 In most thermogravimetry experiments, the masschange is reported as weight percent in which the observedmass at any time during the course o
9、f the experiment is dividedby the original mass of the test specimen. This method ofreporting results assumes that the mass scale of the apparatusis linear with increasing mass. In such cases, it may benecessary only to confirm the performance of the instrument bycomparison to a suitable reference.5
10、.3 When the actual mass of the test specimen is recorded,the use of a calibration factor to correct the calibration of theapparatus may be required, on rare occasions.6. Apparatus6.1 The essential equipment required to provide the mini-mum thermogravimetric analytical capability for this testmethod
11、includes the following:6.1.1 Thermobalance, composed of a furnace;atempera-ture sensor;abalance to measure the specimen mass with aminimum capacity within the range to be calibrated and asensitivity of 6 1 g; and a means of maintaining thespecimen/container under atmospheric control of the gas to be
12、used at a purge rate between 10 to 1006 5 mL/min.NOTE 1Excessive purge rates should be avoided as this may intro-duce noise due to bouyancy effects and temperature gradients.6.1.2 Temperature Controller, capable of maintaining am-bient temperature to 6 1K.6.1.3 Recording Device, capable of recording
13、 and display-ing any fraction of the specimen mass signal including thesignal noise, versus any faction of the temperature signalincluding noise.1This test method is under the jurisdiction of ASTM Committee E37 on ThermalMeasurements and is the direct responsibility of Subcommittee E37.01 on TestMet
14、hods and Recommended Practices.Current edition approved Sept. 10, 2003. Published November 2003. Originallyapproved in 1999. Last previous edition approved in 1999 as E 2040 99.2For referenced ASTM standards, visit the website,www.astm.org, or contactASTM Customer service at serviceastm.org. For Ann
15、ual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTMwebsite.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.1.4 Containers (pans, crucibles, etc.), which are inert tothe specimen an
16、d which will remain gravimetrically stable.7. Reagents and Materials7.1 A reference material of known mass, which is traceableto a national standards laboratory, such as the National Instituteof Standards and Technology (NIST). Such mass referencematerials are available from most general laboratory
17、equipmentsuppliers.7.2 The mass of the reference material should correspond tothe working range of the analysis. For most work, the massmaximumshould be 25 to 50 % greater than the material beingexamined.8. Calibration and Standardization8.1 Perform any mass signal calibration procedures recom-mende
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME20402003STANDARDTESTMETHODFORMASSSCALECALIBRATIONOFTHERMOGRAVIMETRICANALYZERS 分析 质量 刻度 校准 标准 试验

链接地址:http://www.mydoc123.com/p-530126.html