1、Designation: E 2002 98 (Reapproved 2009)Standard Practice forDetermining Total Image Unsharpness in Radiology1This standard is issued under the fixed designation E 2002; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the design and basic use of a gaugeused to determine the total image unsharpness of radiographsand
3、 radioscopic systems.1.2 This practice is applicable to radiographic and radio-scopic imaging systems utilizing X-ray and gamma ray radia-tion sources.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 The gauge described c
4、an be used effectively withradiation energies up to 400 kv. When using energies in themegavolt range the results may not be completely satisfactory.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this st
5、andard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 747 Practice for Design, Manufacture and MaterialGrouping Classification of Wire Image Quality Indicators(IQI) Used for Ra
6、diologyE 1025 Practice for Design, Manufacture, and MaterialGrouping Classification of Hole-Type Image Quality Indi-cators (IQI) Used for RadiologyE 1316 Terminology for Nondestructive ExaminationsE 1647 Practice for Determining Contrast Sensitivity inRadiology2.2 EN Standard:EN-462-5:1994 Nondestru
7、ctive TestingImage Quality ofRadiographsPart 5: Image Quality Indicators (DuplexWire Type)Determination of Total Image UnsharpnessValue33. Terminology3.1 DefinitionsDefinitions of terms applicable to thispractice may be found in Terminology E 1316.4. Summary of Practice4.1 When it is determined nece
8、ssary to evaluate and mea-sure the Total Image Unsharpness (Spatial Resolution) of animaging system separately and apart from contrast sensitivitymeasurements, a tool or gauge as described in this practice canbe used. Conventional IQIs described in Practices E 747 andE 1025 combine the contrast sens
9、itivity and resolution mea-surements into an overall figure of merit. Such figures of meritmay not be adequate to detect subtle changes in the imagingsystems performance. For example, in a high-contrast image,spatial resolution can degrade with almost no noticeable effectupon the overall image quali
10、ty. Similarly, in an application inwhich the imaging system provides a very sharp image,contrast can fade with little noticeable effect upon the overallimage quality, as determined using conventional IQIs. Thesesituations often develop and may go undetected until thesystem performance deteriorates b
11、elow acceptable image qual-ity limits.5. Significance and Use5.1 The gauge is intended to provide a means for measuringtotal image unsharpness as independently as practicable fromthe imaging system contrast sensitivity limitations. Furtherdescription and details of the gauge are provided in EN-462-5
12、:1994.5.2 The gauge can be used in conjunction with a contrastsensitivity measuring gauge, as described in Practice E 1647.6. Gauge Construction6.1 The gauge shall be fabricated in accordance with Fig. 1,using the tolerances given in Table 1. This gauge is identical to1This practice is under the jur
13、isdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.01 onRadiology (X and Gamma) Method.Current edition approved June 1, 2009. Published July 2009. Originally approvedin 1998. Last previous edition approved in 2003 as E 2002 - 98 (2003).2Fo
14、r referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from British Standards Institute (BSI), 389 Chiswick
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME200219982009STANDARDPRACTICEFORDETERMININGTOTALIMAGEUNSHARPNESSINRADIOLOGY 应用 放射学 测定 整体 图像 清晰度 标准

链接地址:http://www.mydoc123.com/p-530023.html