《ASTM E1936-2003(2011)e2 Standard Reference Radiograph for Evaluating the Performance of Radiographic Digitization Systems《评定射线照相数字化系统性能用标准参考射线照片》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1936-2003(2011)e2 Standard Reference Radiograph for Evaluating the Performance of Radiographic Digitization Systems《评定射线照相数字化系统性能用标准参考射线照片》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1936 03 (Reapproved 2011)2Standard Reference Radiograph forEvaluating the Performance of Radiographic DigitizationSystems1This standard is issued under the fixed designation E1936; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEReference source information was updated editorially in November 2014.2NOTEReference radiograph sourc
3、e information was updated editorially in October 2015.1. Scope1.1 This reference radiograph covers a series of test targetssuitable for evaluating, quantifying, and documenting perfor-mance parameters of the radiographic digitization process orthe electronic image reconstruction process, or both. Th
4、isreference radiograph can be used for visual and electronicanalysis of digitization systems. This is the first of three relatedstandards. Subsequent standards will provide guidance on theuse of the test targets and recommended system performancelevels1.2 This reference radiograph provides a series
5、of testtargets to provide a vehicle for the evaluation of spatialresolution, density contrast sensitivity, dynamic range, andspatial linearity as well as other aspects of a digitizationsystem. The test targets are suitable for evaluating a digitiza-tion system with a spatial resolution down to ;1/10
6、00 in. (25micrometres () a density contrast sensitivity down to 0.02optical density (OD), a density range of 0.5 to 4.5 OD, and afilm size capacity of 14 in. (355 mm) wide by 17 in. (431 mm)long.1.3 The values stated in inch-pound units are to be regardedas the standard, with the exception of the sp
7、atial resolutiontargets (6.2 and 6.7) which are stated in SI units.1.4 This standard does not purport to address the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicabili
8、ty of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E1079 Practice for Calibration of Transmission Densitom-etersE1254 Guide for Storage of Radiographs and UnexposedIndustrial Radiographic FilmsE1316 Terminology for Nondestructive ExaminationsE1411 Practice for Qualif
9、ication of Radioscopic Systems2.2 ASME Standard:Section V, Article 2, Mandatory Appendix VI, Digital ImageAcquisition, Display, Interpretation and Storage forNuclear Applications32.3 ASTM Adjuncts:Standard Reference Radiograph for Evaluating the Perfor-mance of Radiographic Digitization Systems43. T
10、erminology3.1 Definitions:3.1.1 Refer to Terminology E1316 for definitions of termsused in this guide.3.2 Definitions of Terms Specific to This Standard:3.2.1 converging line pairsthe targets located on thereference radiograph that are used to determine the spatialresolution of the digitization syst
11、em.3.2.2 parallel line pairsthe targets located on the refer-ence radiograph that are used in conjunction with the converg-ing line pairs to determine the spatial resolution of thedigitization system.1This reference radiograph is under the jurisdiction ofASTM Committee E07 onNondestructive Testing a
12、nd is the direct responsibility of Subcommittee E07.02 onReference Radiological Images.Current edition approved Dec. 1, 2011. Published March 2012. Originallyapproved in 1997. Last previous edition approved in 2011 as E1936 - 03(2011)1.DOI: 10.1520/E1936-03R11E2.2For referenced ASTM standards, visit
13、 the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Society of Mechanical Engineers (ASME), ASMEInternational Headquarters, T
14、hree Park Ave., New York, NY 10016-5990, http:/www.asme.org.4Available from ASTM Headquarters. Order RRE1936.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.3 reference radiographthe single piece of industrialradiographic film con
15、taining all of the reference targets de-scribed in this document.3.2.4 scan lineit is a path that is one pixel high (vertical)by the number of pixels wide (horizontal), that is captured bythe digitization system. The scan lines are added, one on top ofthe other, to electronically reproduce the physi
16、cal (analog) datain the horizontal (film width) and vertical (film length) direc-tions on the display monitor.3.2.5 spatial linearitythe accuracy to which a digitizationsystem reproduces the physical dimension. It is assessed withina single scan line and from one scan line to the next (horizontaland
17、 vertical directions).3.2.6 spatial resolutionit is measured as the minimumdistance detectable between two physically spaced lines (see6.2 spatial resolution targets). It is determined by the samplingrate in physical two-dimensional space and the system un-sharpness.3.2.7 targetsthe physical pattern
18、s on the reference radio-graph that are used to evaluate the radiographic film digitiza-tion system.4. Significance and Use4.1 This reference radiograph may be used to quantify theperformance characteristics of a radiographic digitization sys-tem or to provide periodic evaluations of a digitization
19、systemin a production mode to verify that appropriate operatingcharacteristics are being maintained. This reference radiographprovides a means for verifying the performance of a digitiza-tion system in much the same way that the tests described inPractice E1411, provide for the verification of a rad
20、ioscopicimaging system. It may be used to evaluate the performance ofa digitization system in accordance with the requirementscontained in ASME Section V, Article 2, Mandatory AppendixVI, or other documents invoking requirements of this referenceradiograph.4.2 This reference radiograph provides a to
21、ol that allows theuser to determine the performance of their radiographic digi-tization system. This reference radiograph may be used, wherethere is no other applicable document, for establishing recordsof quality and acceptable levels of performance between thecognizant engineering organization and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME193620032011E2STANDARDREFERENCERADIOGRAPHFOREVALUATINGTHEPERFORMANCEOFRADIOGRAPHICDIGITIZATIONSYSTEMS

链接地址:http://www.mydoc123.com/p-529863.html