《ASTM E1933-1999a(2005)e1 Standard Test Methods for Measuring and Compensating for Emissivity Using Infrared Imaging Radiometers《使用红外成像辐射计测量和补偿发射率的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1933-1999a(2005)e1 Standard Test Methods for Measuring and Compensating for Emissivity Using Infrared Imaging Radiometers《使用红外成像辐射计测量和补偿发射率的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1933 99a (Reapproved 2005)e1Standard Test Methods forMeasuring and Compensating for Emissivity Using InfraredImaging Radiometers1This standard is issued under the fixed designation E 1933; the number immediately following the designation indicates the year oforiginal adoption or, in t
2、he case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEFootnote 2 was editorially changed to include the publication suppliers new address in Mar
3、ch 2005.1. Scope1.1 These test methods cover procedures for measuring andcompensating for emissivity when measuring the surfacetemperature of a specimen with an infrared imaging radiom-eter.21.2 The values stated in SI units are to be regarded as thestandard.1.3 These test methods may involve use of
4、 equipment andmaterials in the presence of heated or electrically-energizedequipment, or both.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pra
5、ctices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E 1316 Terminology for Nondestructive Testing3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 reflected temperaturethe temperature of the energyincident upo
6、n and reflected from the measurement surface ofthe specimen.3.1.2 surface-modifying materialany tape, spray, paint orthe like that is used to change the emissivity of the specimensurface.3.2 See also Terminology E 1316.4. Summary of Test Method4.1 Two test methods are given for measuring the emissiv
7、ityof a specimen surface, the contact thermometer method and thenon-contact thermometer method.4.2 A test method is also given for compensating for theerror produced by emissivity using the computer built into aninfrared imaging radiometer.5. Significance and Use5.1 The emissivity of a specimen can
8、cause surface tem-perature measurement errors. Two test methods are providedfor measuring and compensating for this error source.5.2 These test methods can be used in the field or laboratory,using commonly available materials.5.3 These test methods can be used with any infraredradiometers that have
9、the required computer capabilities.6. Interferences6.1 Contact Thermometer MethodContact thermometerscan act as heat sinks and change the temperature of thespecimen.6.2 Noncontact Thermometer Method:6.2.1 The use of surface-modifying materials can changethe heat transfer properties and temperature o
10、f the specimen.Any such errors can be minimized by applying surface-modifying materials to the smallest area that satisfies themeasurement accuracy requirements of the radiometer andinfrared thermographer.6.2.2 Before the surface-modifying material is applied to anarea of the specimen adjacent to th
11、e area where the emissivityis to be measured (as directed in 8.2.4), errors can beminimized by viewing the imager display to ensure that bothareas have the same temperature.6.2.3 When removing a surface-modifying material, as di-rected in 8.2.7, errors can be minimized by ensuring that thesurface is
12、 returned to its original condition.6.3 Both test methods require the specimen to be at atemperature that is at least 10C warmer or cooler than theambient temperature. Potential errors can be minimized byensuring the stability of the temperature difference between the1These test methods are under th
13、e jurisdiction of ASTM Committee E07 onNondestructive Testing and is the direct responsibility of Subcommittee E07.10 onEmerging NDT Methods.Current edition approved March 1, 2005. Published May 2005. Originallyapproved in 1997. Last previous edition approved in 1999 as E 1933 - 99a.2These test meth
14、ods are adapted from the Guideline for Measuring andCompensating for Reflected Temperature, Emittance and Transmittance developedby the Infraspection Institute, 425 Ellis Street, Burlington, NJ 08016.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Servic
15、e at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.specimen and the ambient temperature during th
16、e test.Also, theemissivity measurement accuracy can be increased by increas-ing this temperature difference.6.4 The emissivity of a specimen may be specific to thetemperature of the specimen and the spectral waveband of theinfrared imaging radiometer used to make the measurement.Therefore, the tempe
17、rature of the specimen and the spectralwaveband of the radiometer should be noted along with themeasured emissivity value.6.5 These test methods are valid only for specimens that areopaque in the waveband of the infrared imaging radiometer.6.6 As the emissivity of a specimen decreases, its reflectiv
18、-ity increases. Careful consideration and avoidance of potentialerror sources, including the precise determination of reflectedtemperature in 8.1.3 and 8.2.3, is required to accuratelymeasure the emissivity values of specimens having loweremissivities. For materials with emissivities less than 0.5,r
19、adiometric temperature measurements and emissivity mea-surements may have a high likelihood of error.7. Apparatus7.1 Calibrated Infrared Imaging Radiometer, with a built-incomputer that allows the infrared thermographer to inputreflected temperatures and emissivity values.7.2 Tripod, or device to su
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME19331999A2005E1STANDARDTESTMETHODSFORMEASURINGANDCOMPENSATINGFOREMISSIVITYUSINGINFRAREDIMAGINGRADIOMETERS

链接地址:http://www.mydoc123.com/p-529850.html