《ASTM E1886-2005 Standard Test Method for Performance of Exterior Windows Curtain Walls Doors and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Dif.pdf》由会员分享,可在线阅读,更多相关《ASTM E1886-2005 Standard Test Method for Performance of Exterior Windows Curtain Walls Doors and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Dif.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1886 05Standard Test Method forPerformance of Exterior Windows, Curtain Walls, Doors, andImpact Protective Systems Impacted by Missile(s) andExposed to Cyclic Pressure Differentials1This standard is issued under the fixed designation E 1886; the number immediately following the design
2、ation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method determines the
3、 performance of exteriorwindows, curtain walls, doors, and impact protective systemsimpacted by missile(s) and subsequently subjected to cyclicstatic pressure differentials. A missile propulsion device, an airpressure system, and a test chamber are used to model someconditions which may be represent
4、ative of windborne debrisand pressures in a windstorm environment. This test method isapplicable to the design of entire fenestration or impactprotection systems assemblies and their installation. The per-formance determined by this test method relates to the abilityof elements of the building envel
5、ope to remain unbreachedduring a windstorm.1.2 The specifying authority shall define the representativeconditions (see 10.1).1.3 The values stated in SI units are to be regarded as thestandard. Values given in parentheses are for information only.Certain values contained in reference documents cited
6、 hereinmay be stated in inch-pound units and must be converted by theuser.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine
7、 the applica-bility of regulatory limitations prior to use. Specific hazardstatements are given in Section 7.2. Referenced Documents2.1 ASTM Standards:2E 330 Test Method for Structural Performance of ExteriorWindows, Curtain Walls, and Doors by Uniform Static AirPressure DifferenceE 631 Terminology
8、of Building ConstructionsE 997 Test Method for Structural Performance of Glass inExterior Windows, Curtain Walls, and Doors Under theInfluence of Uniform Static Loads by Destructive MethodsE 1233 Test Method for Structural Performance of ExteriorWindows, Curtain Walls, and Doors by Cyclic Static Air
9、Pressure Differential2.2 ANSI/ASCE Standard:ANSI/ASCE 7, American Society of Civil Engineers Mini-mum Design Loads for Buildings and Other Structures32.3 American Lumber Standard:Document PS20-94American Softwood Lumber Stan-dard43. Terminology3.1 Definitions: General terms used in this test method
10、aredefined in Terminology E 631.3.2 Definitions of Terms Specific to This Standard:3.2.1 2 3 4 in. lumbera dressed piece of surface dry,softwood lumber as defined in Document PS20-94.3.2.2 air pressure cyclebeginning at a specified air pres-sure differential, the application of positive (negative) p
11、ressureto achieve another specified air pressure differential andreturning to the initial specified air pressure differential.3.2.3 air pressure differentialthe specified differential instatic air pressure across the specimen, creating an inward(outward) load, expressed in Pa (lb/ft2). The maximum a
12、irpressure differential (P) is specified or is equal to the designpressure.3.2.4 basic wind speedthe wind speed as determined bythe specifying authority.3.2.5 design pressurethe uniform static air pressure dif-ference, inward or outward, for which the test specimen would1This test method is under th
13、e jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.51on Performance of Windows, Doors, Skylights, and Curtain Walls.Current edition approved Jan. 1, 2005. Published January 2005. Originallypublished in 1997. Last previous edition appr
14、oved in 2004 as E 1886 04a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from the American Socie
15、ty of Civil Engineers, 1801 Alexander BellDrive, Reston, VA 20191.4Available from the American Lumber Standard Committee, Inc., P.O. Box 210,Germantown, MD 20875.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.be designed under servi
16、ce load conditions using conventionalstructural engineering specifications and concepts. This pres-sure is determined by either analytical or wind tunnel proce-dures (such as are specified in ANSI/ASCE 7).3.2.6 fenestration assemblythe construction intended tobe installed to fill a wall or roof open
17、ing.3.2.7 missilethe object which is propelled toward a testspecimen.3.2.8 positive (negative) cyclic test loadthe specifieddifference in static air pressure, creating an inward (outward)loading, for which the specimen is to be tested under repeatedconditions, expressed in Pa (lb/ft2).3.2.9 impact p
18、rotective systemconstruction applied, at-tached, or locked over an exterior glazed opening system toprotect that system from windborne debris during high windevents.3.2.9.1 DiscussionImpact protective system include typesthat are fixed, operable, or removable.3.2.10 specifying authoritythe entity re
19、sponsible for de-termining and furnishing information required to perform thistest method.3.2.11 test loading programthe entire sequence of airpressure cycles to be applied to the test specimen.3.2.12 test specimenthe entire assembled unit submittedfor test.3.2.13 windborne debrisobjects carried by
20、the wind inwindstorms.3.2.14 windstorma weather event, such as a hurricane,with high sustained winds and turbulent gusts capable ofgenerating windborne debris.4. Summary of Test Method4.1 This test method consists of mounting the test specimen,impacting the test specimen with a missile(s), and thena
21、pplying cyclic static pressure differentials across the testspecimen in accordance with a specified test loading program,observing and measuring the condition of the test specimen,and reporting the results.5. Significance and Use5.1 Structural design of exterior windows, curtain walls,doors, and imp
22、act protective systems is typically based onpositive and negative design pressure(s). Design pressuresbased on wind speeds with a mean recurrence interval (usually25100 years) that relates to desired levels of structuralreliability and are appropriate for the type and importance ofthe building (1).5
23、The adequacy of the structural design issubstantiated by other test methods such as Test Methods E 330and E 1233 which discuss proof loads as added factors ofsafety. However, these test methods do not account for otherfactors such as impact from windborne debris followed byfluctuating pressures asso
24、ciated with a severe windstorm envi-ronment. As demonstrated by windstorm damage investiga-tions, windborne debris is present in hurricanes and has causeda significant amount of damage to building envelopes (2-7).The actual in-service performance of fenestration assembliesand impact protective syste
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME18862005STANDARDTESTMETHODFORPERFORMANCEOFEXTERIORWINDOWSCURTAINWALLSDOORSANDIMPACTPROTECTIVESYSTEMSIMPACTEDBYMISSILESANDEXPOSEDTOCYCLICPRESSUREDIFPDF

链接地址:http://www.mydoc123.com/p-529724.html