1、Designation: E 1814 96 (Reapproved 2007)Standard Practice forComputed Tomographic (CT) Examination of Castings1This standard is issued under the fixed designation E 1814; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a uniform procedure for the exami-nation of castings by the computed tomography (CT) tech-nique.
3、 The requirements expressed in this practice are intendedto control the quality of the nondestructive examination by CTand are not intended for controlling the acceptability or qualityof the castings. This practice implicitly suggests the use ofpenetrating radiation, specifically X rays and gamma ra
4、ys.1.2 This practice provides a uniform procedure for a CTexamination of castings for one or more of the followingpurposes:1.2.1 Examining for discontinuities, such as porosity, inclu-sions, cracks, and shrink;1.2.2 Performing metrological measurements and determin-ing dimensional conformance; and1.
5、2.3 Determining reverse engineering data, that is, creatingcomputer-aided design (CAD) data files.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health
6、 practices and determine the applica-bility of regulatory limitations prior to use. For specific safetystatements, see Section 7, NBS Handbook 114,2and21 CFR 1020.40 and 29 CFR 1910.96.2. Referenced Documents2.1 ASTM Standards:3E 543 Specification for Agencies Performing Nondestruc-tive TestingE 131
7、6 Terminology for Nondestructive ExaminationsE 1441 Guide for Computed Tomography (CT) ImagingE 1570 Practice for Computed Tomographic (CT) Exami-nationE 1672 Guide for Computed Tomography (CT) SystemSelectionE 1695 Test Method for Measurement of Computed Tomog-raphy (CT) System Performance2.2 ASNT
8、Documents:4SNT-TC-1A Recommended Practice for Personnel Qualifi-cation and Certification in Nondestructive TestingANSI/ASNT CP-189 Standard for Personnel Qualificationand Certification of Nondestructive Testing Personnel2.3 Military Standards:5MIL-STD-410 Nondestructive Testing Personnel Qualifica-t
9、ion and CertificationNAS 410 Certification and Qualification of NondestructiveTest Personnel2.4 Code of Federal Regulations:521 CFR 1020.40 Safety Requirements of Cabinet X RaySystems29 CFR 1910.96 Ionizing Radiation3. Terminology3.1 DefinitionsDefinitions of terms applicable to thispractice may be
10、found in Terminology E 1316 and GuideE 1441.3.2 Definitions of Terms Specific to This Standard:3.2.1 fixturingthe mounting hardware used to place theobject in the CT system.3.2.2 representative quality indicator (RQI)a real part, ora fabrication of similar geometry in radiologically similarmaterial
11、to a real part, that has features of known characteris-tics that represent all of the features for which the parts arebeing examined.3.2.3 scan planscan locations and the system configura-tion parameters for a specific part examination.3.2.4 objecta part or specimen being subjected to CTexamination.
12、4. Significance and Use4.1 CT may be performed on an object when it is in theas-cast, intermediate, or final machined condition. A CT1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.01 onRadiology (X and Ga
13、mma) Method.Current edition approved July 1, 2007. Published July 2007. Originally approvedin 1996. Last previous edition approved in 2002 as E 1814 - 96(2002).2NBS Handbook 114, General Safety Standard for Installations, Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies Up to 10 MeV, N
14、ationalInstitute of Standards and Technology (NIST), Gaithersburg, MD.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM
15、 website.4Available fromAmerican Society for Nondestructive Testing (ASNT), P.O. Box28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http:/www.asnt.org.5Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/www.dodssp.
16、daps.mil.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.examination can be used as a design tool to improve wax formsand moldings, establish process parameters, randomly checkprocess control, perform final quality control (QC) exami
17、na-tion for the acceptance or rejection of parts, and analyzefailures and extend component lifetimes.4.2 The most common applications of CT for castings arefor the following: locating and characterizing discontinuities,such as porosity, inclusions, cracks, and shrink; measuringas-cast part dimension
18、s for comparison with design dimen-sions; and extracting dimensional measurements for reverseengineering.4.3 The extent to which a CT image reproduces an object ora feature within an object is dictated largely by the competinginfluences of spatial resolution, contrast discrimination, andartifacts of
19、 the imaging system. Operating parameters strike anoverall balance between image quality, examination time, andcost.4.4 Artifacts are often the limiting factor in CT imagequality. (See Practice E 1570 for an in-depth discussion ofartifacts.) Artifacts are reproducible features in an image thatare no
20、t related to actual features in the object. Artifacts can beconsidered correlated noise because they form repeatable fixedpatterns under given conditions yet carry no object informa-tion. For castings, it is imperative to recognize what is and isnot an artifact since an artifact can obscure or masqu
21、erade as adiscontinuity.Artifacts are most prevalent in castings with longstraight edges or complex geometries, or both.5. Basis of Application5.1 The following items shall be agreed upon between thepurchaser and the supplier and specified in the contract or joborder:5.1.1 Nondestructive Testing Age
22、ncy EvaluationThe useof a nondestructive testing (NDT) agency, as defined inPractice E 543. If a systematic assessment of the capability ofthe agency is specified, a documented procedure, such as thatdescribed in Practice E 543, should be used as the basis forevaluation.5.1.2 Personnel Qualification
23、sAll CT examination per-sonnel shall be qualified and certified in accordance with awritten procedure conforming to ANSI/ASNT CP-189, SNT-TC-1A, MIL-STD-410, NAS 410, or a similar document. Thewritten procedure shall include training that addresses CTissues specifically.5.1.3 General RequirementsGen
24、eral requirements shallbe specified in accordance with Section 8:(1) written proce-dure, 8.1; and (2) CT system validation measurements, 8.3.5.1.3.1 Specific requirements regarding preparation and ap-proval of the written procedures should be agreed upon inadvance by the purchaser and the supplier.5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME181419962007STANDARDPRACTICEFORCOMPUTEDTOMOGRAPHICCTEXAMINATIONOFCASTINGS 涂层 计算机 层析 摄影 CT 检查 标准

链接地址:http://www.mydoc123.com/p-529519.html