ASTM E1791-1996(2014) Standard Practice for Transfer Standards for Reflectance Factor for Near-Infrared Instruments Using Hemispherical Geometry《使用半球形几何结构测定近红外仪器反射系数传递标准的标准实施规程》.pdf
《ASTM E1791-1996(2014) Standard Practice for Transfer Standards for Reflectance Factor for Near-Infrared Instruments Using Hemispherical Geometry《使用半球形几何结构测定近红外仪器反射系数传递标准的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1791-1996(2014) Standard Practice for Transfer Standards for Reflectance Factor for Near-Infrared Instruments Using Hemispherical Geometry《使用半球形几何结构测定近红外仪器反射系数传递标准的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1791 96 (Reapproved 2014)Standard Practice forTransfer Standards for Reflectance Factor for Near-InfraredInstruments Using Hemispherical Geometry1This standard is issued under the fixed designation E1791; the number immediately following the designation indicates the year oforiginal ad
2、option or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe internationally accepted standard of reflectance is the perfect re
3、flecting diffuser. This idealreflecting surface reflects 100 % of the radiant power incident on it, such that the radiance is the samefor all directions within the hemisphere of solid angles. No physical realization of this standard exists.Optical properties of standards prepared from pressed plaque
4、s of barium sulfate (BaSO4)orpolytetrafluoroethylene (PTFE), as well as commercially available samples of sintered PTFE (1-4),2can approximate those of a white material. For further information, see Commission Internationale deLEclairage (CIE) Publication No. 46 (5). Additional transfer standards ar
5、e required that have a verystable reflectance factor that is constant with wavelength and that have a range of values from nearzero to close to that of the perfect reflecting diffuser. Such materials as carbon-black doped sinteredPTFE (6-8) fulfill this requirement. The principle uses of a reflectan
6、ce factor standard are fortransferring an absolute scale of reflectance to a more durable material or for calibrating near-infrared(NIR) spectrophotometers for linearity of reflectance scale. In theory, this transfer, conducted fromfirst principles, should be quite easy. In practice, values are like
7、ly to be required for parameters thatare unknown, proprietary, or require a highly sophisticated level of skill. Some, but not all, of theseparameters are discussed in this practice.1. Scope1.1 This practice covers procedures for the preparation anduse of acceptable transfer standards for NIR spectr
8、ophotom-eters. Procedures for calibrating the reflectance factor ofmaterials on an absolute basis are contained in CIE PublicationNo. 44 (9). Both the pressed powder samples and the sinteredPTFE materials are used as transfer standards for such calibra-tions because they have very stable reflectance
9、 factors that arenearly constant with wavelength and because the distributionof flux resembles closely that from the perfect reflectingdiffuser.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purpo
10、rt to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E131
11、 Terminology Relating to Molecular SpectroscopyE259 Practice for Preparation of Pressed Powder WhiteReflectance Factor Transfer Standards for Hemisphericaland Bi-Directional GeometriesE284 Terminology of Appearance3. Terminology3.1 DefinitionsTerms and definitions in TerminologyE284 are applicable t
12、o this practice.3.2 Descriptions of Terms Specific to This StandardThefollowing definitions are particularly important to this practice.3.2.1 linearitythe ability of a photometric system to yielda linear relationship between the radiant power incident on its1This practice is under the jurisdiction o
13、f ASTM Committee E13 on MolecularSpectroscopy and Separation Science and is the direct responsibility of Subcom-mittee E13.03 on Infrared and Near Infrared Spectroscopy.Current edition approved May 1, 2014. Published June 2014. Originallyapproved in 1996. Last previous edition approved in 2008 as E1
14、791 96 (2008)1.DOI: 10.1520/E1791-96R14.2The boldface numbers in parentheses refer to the list of references at the end ofthis practice.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume in
15、formation, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1detector and some measurable quantity provided by the system.(E131)3.2.2 near-infrared, adjthe region of the el
16、ectromagneticspectrum for radiation of wavelengths between 780 and 2500nm (0.78 and 2.50 m).3.2.3 perfect reflecting diffuserideal reflecting surface thatneither absorbs nor transmits light, but reflects diffusely, withthe radiance of the reflecting surface being the same for allreflecting angles, r
17、egardless of the angular distribution of theincident light.3.2.4 reflectance, r, nratio of the reflected radiant orluminous flux to the incident flux in the given conditions (1).3.2.4.1 The term reflectance is often used in a general senseor as an abbreviation for reflectance factor. Such usage may
18、beassumed unless the definition is specifically required by thecontext.3.2.5 reflectance factor, R, nratio of the flux reflected fromthe specimen to the flux reflected from the perfect reflectingdiffuser under the same geometric and spectral conditions ofmeasurement (2).4. Summary of Practice4.1 Pro
19、cedures for the preparation of packed powdersamples of barium sulfate and PTFE can be found in PracticeE259. Sintered PTFE samples are commercially available.Reflectance data for this material are given in Table 1. Thesematerials provide close approximation to the optical propertiesof the perfect re
20、flecting diffuser and may be used to transfer ascale of reflectance factor to another material or instrument.4.2 Sintered carbon-black doped PTFE samples are alsocommercially available and are described in Table 2. Thesematerials provide close approximation to the optical propertiesof a perfect refl
21、ecting diffuser with spectrally neutral absor-bance features and may be used to transfer a scale of linearityin reflectance factor to another material or instrument.5. Significance and Use5.1 Most commercial reflectometers and spectrophotom-eters with reflectance capability measure relative reflecta
22、nce.The instrument reading is the ratio of the measured radiationreflected from the reference specimen to the measured radia-tion reflected by the test specimen. That ratio is dependent onspecific instrument parameters.5.2 National standardizing laboratories and some researchlaboratories measure ref
23、lectance on instruments calibratedfrom basic principles, thereby establishing a scale of absolutereflectance as described in CIE Publication No. 44 (5). Thesemeasurements are sufficiently difficult and of prohibitive costthat they are usually left to laboratories that specialize in them.5.3 A standa
24、rd that has been measured on an absolute scalecould be used to transfer that scale to a reflectometer. Whilesuch procedures exist, the constraints placed on the mechanicalproperties restrict the suitability of some of the opticalproperties, especially those properties related to the geometricdistrib
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME179119962014STANDARDPRACTICEFORTRANSFERSTANDARDSFORREFLECTANCEFACTORFORNEARINFRAREDINSTRUMENTSUSINGHEMISPHERICALGEOMETRY

链接地址:http://www.mydoc123.com/p-529471.html