ASTM E1646-1995(2011) Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference《采用均匀静态空气压差分析外部金属屋面板系统防水漏性能的标准试验方法》.pdf
《ASTM E1646-1995(2011) Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference《采用均匀静态空气压差分析外部金属屋面板系统防水漏性能的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1646-1995(2011) Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference《采用均匀静态空气压差分析外部金属屋面板系统防水漏性能的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1646 95 (Reapproved 2011)Standard Test Method forWater Penetration of Exterior Metal Roof Panel Systems byUniform Static Air Pressure Difference1This standard is issued under the fixed designation E1646; the number immediately following the designation indicates the year oforiginal ado
2、ption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the resis-tance of exterio
3、r metal roof panel systems to water penetrationwhen water is applied to the outdoor face simultaneously witha static air pressure at the outdoor face higher than the pressureat the indoor face, that is, positive pressure. This test method isa specialized adaption of Test Method E331.1.2 This test me
4、thod is applicable to any roof area and isintended to measure only the water penetration associated withthe field of roof including panel side laps and structuralconnections. It does not include leakage at openings orperimeter or any other details.1.3 This test method is limited to specimens in whic
5、h theside seams and attachments are clearly visible and in which thesource of leakage is readily determined. Composite systems inwhich the source cannot be readily determined are outside thescope of this test method.1.4 The proper use of this test method requires a knowledgeof the principles of pres
6、sure and flow measurement.1.5 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only and may be approximate.1.6 The text of this test method references notes andfootnotes excluding tables and figures, which provide explana-tor
7、y material. These notes and footnotes shall not be consid-ered as requirements of the test method.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health
8、 practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see 7.1.2. Referenced Documents2.1 ASTM Standards:2E331 Test Method for Water Penetration of Exterior Win-dows, Skylights, Doors, and Curtain Walls by UniformStatic Air Pressure Differe
9、nceE631 Terminology of Building ConstructionsE1680 Test Method for Rate of Air Leakage ThroughExterior Metal Roof Panel SystemsE1592 Test Method for Structural Performance of SheetMetal Roof and Siding Systems by Uniform Static AirPressure Difference2.2 Other Standards:AAMA 501 Methods of Test for M
10、etal Curtain Walls33. Terminology3.1 DefinitionsFor definitions of general terms relating tobuilding construction used in this test method, see TerminologyE631.3.2 Descriptions of Terms Specific to This Standard:3.2.1 specimenthe entire assembled unit submitted fortest as described in Section 8.3.2.
11、2 test pressure differencethe specified difference instatic air pressure across the assembled and fixed specimenexpressed as pounds-force per square foot (newtons per squaremetre (pascals).3.2.3 water leakagepenetration of water onto the exposedinside surface of the test specimen under specified con
12、ditionsof air pressure difference across the specimen during a 15-mintest period. Water penetration at or around end dams or siderails is not leakage; end dams and side rails are installed tocause and control ponding over the panels and to support thepanels. They are not part of the roof.1This test
13、method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.57on Performance of Metal Roof Systems.Current edition approved March 1, 2011. Published March 2011. Originallyapproved in 1995. Last previous edition approved in 20
14、03 as E1646 95 (2003).DOI: 10.1520/E1646-95R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available fro
15、m Architectural Aluminum Manufacturers Association (AAMA),1827 Walden Office Square, Suite 550, Schaumburg, IL 60173, http:/www.aamanet.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Summary of Test Method4.1 This test method
16、 consists of sealing and fixing the testspecimen into or against one face of a test chamber, supplyingair to or exhausting air from the chamber at the rate required tomaintain the test pressure difference across the specimen, whilespraying water onto the outdoor face of the specimen at therequired r
17、ate and observing any water leakage.5. Significance and Use5.1 This test method is a standard procedure for determiningthe resistance to water penetration under uniform positive staticair pressure differences, and simulates wind driven rain im-posed on sidelaps and rain that is free to drain while b
18、uildinga water head as it flows. The slope of the roof is significant.These factors shall be fully considered prior to specifying thetest pressure difference.NOTE 1In applying the results of tests by this method, note that theperformance of a roof or its components, or both, may be a function ofprop
19、er installation and adjustment. In service, the performance alsodepends on the rigidity of supporting construction, roof slope, and on theresistance of components to deterioration by various causes: corrosiveatmosphere, aging, ice, vibration, thermal expansion and contraction, etc.It is difficult to
20、 simulate the identical complex wetting conditions that canbe encountered in service, including large wind-blown water drops,increasing water drop impact pressures with increasing wind velocity, andlateral or upward moving air and water. Some designs are more sensitivethan others to this upward movi
21、ng water.NOTE 2This is a test procedure. It is the responsibility of thespecifying agency to determine the specimen construction, size, and testpressures after considering the methods guidelines. Practical consider-ations suggest that every combination of panel thickness, span, and designload need n
22、ot be tested in order to substantiate product performance.NOTE 3This test method shall not, by itself, be relied upon to formconclusions about overall water penetration through metal roofs. A roofcontains many details. Although prescribed modifications are outside thescope of this test method, an ex
23、perienced testing engineer is able to use theprinciples presented in this test method and generate significant data byisolating specific details and measuring leakage.6. Apparatus6.1 The description of apparatus in this section is general innature, and any arrangement of equipment capable of perform
24、-ing the test procedure within the allowable tolerances ispermitted.6.2 Major Components (see Fig. 1):6.2.1 Test ChamberA test chamber or box with either anopening, a removable mounting panel, or one open face inwhich or against which the specimen is installed and sealed.The specimen shall be instal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME164619952011STANDARDTESTMETHODFORWATERPENETRATIONOFEXTERIORMETALROOFPANELSYSTEMSBYUNIFORMSTATICAIRPRESSUREDIFFERENCE

链接地址:http://www.mydoc123.com/p-529133.html