ASTM E1600-2013 Standard Test Method for Determination of Gold in Cyanide Solutions by Flame Atomic Absorption Spectrometry《用火焰原子吸收光谱法测定氰化物溶液中金的标准试验方法》.pdf
《ASTM E1600-2013 Standard Test Method for Determination of Gold in Cyanide Solutions by Flame Atomic Absorption Spectrometry《用火焰原子吸收光谱法测定氰化物溶液中金的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1600-2013 Standard Test Method for Determination of Gold in Cyanide Solutions by Flame Atomic Absorption Spectrometry《用火焰原子吸收光谱法测定氰化物溶液中金的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1600 07E1600 13Standard Test Method forDetermination of Gold in Cyanide Solutions by FlameAtomic Absorption Spectrometry1This standard is issued under the fixed designation E1600; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of gold in ore processing cyanide solution in the ran
3、ge from 0.3 g/mL to 10.0g/mL of gold by direct aspiration into an atomic absorption spectrophotometer.spectrometer.1.1.1 This test method may also be applied to cyanide leach solutions from metallurgical evaluation procedures.1.2 The values stated in SI units are to be regarded as standard. No other
4、 units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of
5、regulatorylimitations prior to use. Specific precautions are given in 8.1, 8.38.1.1, 8.5, Section 9, and 10.4.1.111.2.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD1293 Test Methods for pH of WaterD6888 Test Method forAvailable Cyanide with Ligand Displacement and
6、Flow InjectionAnalysis (FIA) Utilizing Gas DiffusionSeparation and Amperometric DetectionD7237 Test Method for Free Cyanide with Flow InjectionAnalysis (FIA) Utilizing Gas Diffusion Separation andAmperometricDetectionE29 Practice for Using Significant Digits in Test Data to Determine Conformance wit
7、h SpecificationsE50 Practices forApparatus, Reagents, and Safety Considerations for ChemicalAnalysis of Metals, Ores, and Related MaterialsE135 Terminology Relating to Analytical Chemistry for Metals, Ores, and Related MaterialsE173 Practice for Conducting Interlaboratory Studies of Methods for Chem
8、ical Analysis of Metals (Withdrawn 1998)3E663 Practice for Flame Atomic Absorption Analysis (Withdrawn 1997)3E882 Guide for Accountability and Quality Control in the Chemical Analysis LaboratoryE1024 Guide for Chemical Analysis of Metals and Metal Bearing Ores by Flame Atomic Absorption Spectrophoto
9、metry(Withdrawn 2004)3E1060 Practice for Interlaboratory Testing of Spectrochemical Methods of Analysis (Withdrawn 1997)3E1601 Practice for Conducting an Interlaboratory Study to Evaluate the Performance of an Analytical Method3. Terminology3.1 DefinitionsFor definitions of terms used in this test m
10、ethod, refer to Terminology E135.4. Summary of Test Method4.1 The sample solution is collected and preserved with sodium hydroxide, if necessary, by careful adjustment of pH. The testsolution is filtered and gold content is determined by flame atomic absorption spectrophotometry.spectrometry.1 This
11、test method is under the jurisdiction of ASTM Committee E01 on Analytical Chemistry for Metals, Ores, and Related Materials and is the direct responsibility ofSubcommittee E01.02 on Ores, Concentrates, and Related Metallurgical Materials.Current edition approved June 1, 2007April 1, 2013. Published
12、June 2007June 2013. Originally approved in 1994. Last previous edition approved in 20022007 asE1600 02.E1600 07. DOI: 10.1520/E1600-07.10.1520/E1600-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Sta
13、ndardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what ch
14、anges have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the off
15、icial document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Significance and Use5.1 In primary metallurgical processes for gold bearing ores, gold is extracted with an alkaline cyanide solution. Metallurgicalaccounting, process
16、control, and ore evaluation procedures depend on accurate, precise, and prompt measurements of the goldconcentrations.5.2 This test method is a comparative referee method for compliance with compositional specifications for metal content.concentration or to monitor processes. It is assumed that all
17、who use this proceduremethod will be trained analysts capable ofperforming common laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equippedlaboratory and that proper waste disposal procedures will be followed. Follow under appropriate quality cont
18、rol practices such asthose described in Guide E882., and that proper waste disposal procedures will be followed.6. Interferences6.1 Elements normally found in ore processing cyanide solutions do not interfere. Use of instrumental background correctionis required to compensate for nonspecific absorpt
19、ion interferences in the flame.7. Apparatus7.1 Atomic Absorption Spectrophotometer,Spectrometer, equipped with background correction and capable of measuring goldat the 242.8-nm wavelength using an air and acetylene flame over a linear range from 0.3 g/mL to 10.0 g/mL gold.8. Reagents and Materials8
20、.1 Gold Calibration Solutions (0.5, 1.0, 2.0, 5.0, 10.0) g/mLIn a fume hood, pipette 10 mL of Gold Standard Solution A(8.2) into a 1-L volumetric flask containing 100 mL of Sodium Cyanide-Sodium Hydroxide Solution (8.5). Dilute to volume andmix (10 g/mL).8.1.1 Pipette (5, 10, 20, and 50) mL of the 1
21、0 g/mL gold calibration solution into each of four 100-mL volumetric flasks,respectively. Add 10 mL of Sodium Cyanide-Sodium Hydroxide Solution (8.5), dilute to volume, and mix.WARNINGReaction of acid or chlorine and cyanide solutions releases toxic hydrogen cyanide or cyanogen chloride gases.Prepar
22、e in a fume hood.8.2 Gold Standard Solution A (1 mL 1.0 g Au)Weigh 1.000 g of gold metal (99.99 % minimum purity) and transfer to a1-L beaker in a fume hood. Add 200 mL of water, 80 mL of HCl, and 50 mL of HNO3 (1 + 1). Boil gently to expel NOx fumes,cool, transfer to a 1-L volumetric flask, dilute
23、to volume, and mix.8.2.1 A certified reference solution meeting these specifications may also be used.8.3 Reference SolutionDilute 100 mL of Sodium Cyanide-Sodium Hydroxide Solution (8.5), to 1 L with water.8.4 Sodium Cyanide.8.5 Sodium CyanideSodium Hydroxide SolutionDissolve 10 g of sodium hydroxi
24、de and 10 g of sodium cyanide in 1 L ofwater.WARNING The preparation, storage, use, and disposal of sodium cyanide solutions require special care and attention.Avoidany possibility of inhalation, ingestion, or skin contact with the compound, its solution, or its vapors.Work only in a well-ventilated
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME16002013STANDARDTESTMETHODFORDETERMINATIONOFGOLDINCYANIDESOLUTIONSBYFLAMEATOMICABSORPTIONSPECTROMETRY

链接地址:http://www.mydoc123.com/p-529021.html