ASTM E1592-2005 Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference《用均匀静态空气压差法测定薄金属板屋顶和板壁系统结构性能的标准试验方法》.pdf
《ASTM E1592-2005 Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference《用均匀静态空气压差法测定薄金属板屋顶和板壁系统结构性能的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1592-2005 Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference《用均匀静态空气压差法测定薄金属板屋顶和板壁系统结构性能的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1592 05Standard Test Method forStructural Performance of Sheet Metal Roof and SidingSystems by Uniform Static Air Pressure Difference1This standard is issued under the fixed designation E 1592; the number immediately following the designation indicates the year oforiginal adoption or,
2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONComputations are the accepted method for determining the structural capacity of
3、 most metalproducts. However, some conditions are outside the scope of analysis by industry specifications.Methods of computation and a discussion of these conditions are found in the following documents:AISI Specification for the Design of Cold-Formed Steel Structural Members and Load and Resistanc
4、eFactor Specification for Cold-Formed Steel Structural Members and Aluminum Association Specifi-cations for Aluminum Structures.This test method is not to be considered as a wind design standard. It is a structural capacity testto determine the ability of a panel system (including attachments) to re
5、sist uniform static pressure.Actual wind pressure is nonuniform and dynamic. These uniform static test results should be used inconjunction with commonly recognized wind design standards, and will yield highly conservativeresults.When additional fasteners are installed across panel flats at eaves, r
6、idges, or reinforced end laps, thecrosswise distortion is eliminated and both flexural capacity and anchor-to-panel attachment strengthcan vary with the distance from such conditions. This test procedure can be used to evaluate thestrength of panels and attachments at any distance from end or edge p
7、erimeter conditions. The size ofthe specimen and limitations on air seals are designed to minimize any interference with the naturalresponse of the panels under load.1. Scope1.1 This test method covers the evaluation of the structuralperformance of sheet metal panels and anchor-to-panel attach-ments
8、 for roof or siding systems under uniform static airpressure differences using a test chamber or support surface.1.2 The provisions of this test method are applicable tostanding seam, trapezoidal, ribbed, or corrugated metal panelsin the range of thickness from 0.012 to 0.050-in. (0.3 to1.3-mm) and
9、apply to the evaluation of uniform pressureapplied to single-skin construction or one sheet metal layer ofmultiple-skin construction. They do not cover requirements forthe construction of a specimen to determine the load sharingthat can occur with either composite or multiple-layer con-struction suc
10、h as: (1) metal cladding over wood sheathing; or(2) field assemblies of insulation sandwiched between corru-gated or formed metal panels.1.3 Proper use of this test method requires knowledge of theprinciples of pressure and deflection measurement.1.4 This test method describes optional apparatus and
11、 pro-cedures for use in evaluating the structural performance of agiven system for a range of support spacings or for confirmingthe structural performance of a specific installation.1.5 The values stated in inch-pound units are to be regardedas the standard. The metric equivalents of inch-pound unit
12、s areapproximate.1.6 The text of this standard references notes and footnotesexclusive of those for tables and figures. These notes andfootnotes provide explanatory material and shall not be con-sidered as requirements of the standard.1This test method is under the jurisdiction of ASTM Committee E06
13、 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.57on Performance of Metal Roofing Systems.Current edition approved June 1, 2005. Published June 2005. Originallyapproved in 1995. Last previous edition approved in 2001 as E 1592 01.1Copyright ASTM International, 100 Ba
14、rr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and deter
15、mine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 7.2. Referenced Documents2.1 ASTM Standards:2A 370 Test Methods and Definitions for Mechanical Testingof Steel ProductsB 557 Test Methods for Tension Testing Wrought and CastAluminum- an
16、d Magnesium-Alloy Products2.2 Aluminum Association Standard:3Aluminum Formed-Sheet Building Sheathing DesignGuide, Appendix B of Specifications for Aluminum Struc-tures, Latest Edition2.3 AISI Standards:4Specification for the Design of Cold-Formed Steel Struc-tural Members, Latest Edition2.4 Other D
17、ocuments:ASCE7 (Formerly ANSI A58.1) Minimum Design Loadsfor Buildings and Other Structures53. Terminology3.1 Descriptions of Terms Specific to This Standard:3.1.1 anchor, na fastener, bolt, screw, or formed devicesuch as a clip that connects panels to the support structure.3.1.2 anchor failure, nan
18、y failure at the anchor device,including separation of the device from the panel, of the deviceitself, or of the connection to the structural support.3.1.3 crosswise restraint, nany attachment in the flat of apanel between structural elements that controls or limits pandistortion under pressure.3.1.
19、4 failure, nfracture or disengagement of any of thecomponents where the system is no longer capable of sustain-ing load, or the system no longer functions as a weathertightmembrane.3.1.5 interior support, nany support other than those ateither extreme in a series of supports for a continuous panel.3
20、.1.6 pan distortion, ndisplacement under load of nor-mally flat portions of a panel profile normal to the plane of theroof or wall surface.3.1.7 panel deflection, ndisplacement under load mea-sured normal to the plane of the roof or wall surface of alongitudinal structural element as measured from a
21、 straight linebetween structural supports.3.1.8 permanent deformation, nthe permanent displace-ment in any direction from an original position that remainsafter an applied load has been removed.63.1.9 reference zero load, nnominal pressure applied to aspecimen to provide a reference position free of
22、 variationsfrom internal stresses or friction within the system assembly.3.1.10 rib spread, npanel distortion under load at the baseof a rib or standing seam as measured crosswise to the rib in theplane of the roof or wall surface.3.1.11 span length, nthe center-to-center distance be-tween anchors o
23、r supports measured parallel to the longitudinalaxis of the panel.3.1.12 specimen, nthe entire assembled unit submitted fortesting, as described in Section 8.3.1.13 specimen length, nthe distance from center tocenter of the end supports; the sum of individual span lengths.3.1.14 structural element,
24、nthe width of a panel profile asmeasured between center lines of repeating longitudinal stiff-eners for continuously supported panels in a positive load testor the width between anchor attachments to repeating stiffenerelements in a negative load test.3.1.15 test load, nthe difference in static air
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME15922005STANDARDTESTMETHODFORSTRUCTURALPERFORMANCEOFSHEETMETALROOFANDSIDINGSYSTEMSBYUNIFORMSTATICAIRPRESSUREDIFFERENCE

链接地址:http://www.mydoc123.com/p-529009.html