ASTM E1545-2011 Standard Test Method for Assignment of the Glass Transition Temperature by Thermomechanical Analysis《使用热机分析的玻璃转变温度的标准试验方法》.pdf
《ASTM E1545-2011 Standard Test Method for Assignment of the Glass Transition Temperature by Thermomechanical Analysis《使用热机分析的玻璃转变温度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1545-2011 Standard Test Method for Assignment of the Glass Transition Temperature by Thermomechanical Analysis《使用热机分析的玻璃转变温度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1545 11Standard Test Method forAssignment of the Glass Transition Temperature byThermomechanical Analysis1This standard is issued under the fixed designation E1545; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes procedures for the assign-ment of the glass transition temperature of materials on
3、heatingusing thermomechanical measurements under compressionexperimental conditions.1.2 This test method is applicable to amorphous or topartially crystalline materials that are sufficiently rigid belowthe glass transition to inhibit indentation by the sensing probe.1.3 The normal operating temperat
4、ure range is from 100to 600 C. This temperature range may be extended dependingupon the instrumentation used.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This test method is related to ISO 11359-2. ISO 11359-2addition
5、ally covers the determination of coefficient of linearthermal expansion not covered by this test method. This testmethod is related to IEC 61006 but uses a slower heating rate.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsib
6、ility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in Section 7.2. Referenced Documents2.1 ASTM Standards:2E473 Terminology Relating to Thermal
7、Analysis and Rhe-ologyE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE1142 Terminology Relating to Thermophysical PropertiesE1363 Test Method for Temperature Calibration of Ther-momechanical Analyzers2.2 Other Standard:ISO 11359-2 PlasticsThermomechan
8、icalAnalysis (TMA) Part 2: Determination of Coefficient of Linear ThermalExpansion and Glass Transition Temperature3IEC 61006 Methods of Test for the Determination of theGlass Transition Temperature of Electrical Insulating Ma-terials43. Terminology3.1 DefinitionsThe following terms are applicable t
9、o thistest method and can be found in Terminologies E473 andE1142: thermomechanical analysis (TMA), thermomechanicalmeasurement, thermodilatometry, glass transition, glass tran-sition temperature, and linear thermal expansion.4. Summary of Test Method4.1 This test method uses thermomechanical analys
10、is equip-ment (thermomechanical analyzer, dilatometer, or similar de-vice) to assign the change in dimension of a specimen observedwhen the material is subjected to a constant heating ratethrough its glass transition. This change in dimension associ-ated with the change from vitreous solid to amorph
11、ous liquid isobserved as movement of the sensing probe in direct contactwith the specimen and is recorded as a function of temperature.The intersection of the extrapolation of the slope of the probedisplacement curve before and after the transition is used todetermine the glass transition temperatur
12、e.5. Significance and Use5.1 The glass transition is dependent on the thermal historyof the material to be tested. For amorphous and semicrystallinematerials the assignment of the glass transition temperaturemay lead to important information about thermal history,processing conditions, stability, pr
13、ogress of chemical reactions,and mechanical and electrical behavior.5.2 Thermomechanical analysis provides a rapid means ofdetecting changes in hardness or linear expansion associatedwith the glass transition.1This test method is under the jurisdiction ofASTM Committee E37 on ThermalMeasurements and
14、 is the direct responsibility of Subcommittee E37.10 on Funda-mental, Statistical and Mechanical Properties.Current edition approved April 1, 2011. Published May 2011. Originallyapproved in 1993. Last previous edition approved in 2005 as E1545 05. DOI:10.1520/E1545-11.2For referenced ASTM standards,
15、 visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New
16、York, NY 10036, http:/www.ansi.org.4Available from International Electrotechnical Commission (IEC), 3 rue deVaremb, Case postale 131, CH-1211, Geneva 20, Switzerland, http:/www.iec.ch.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5
17、.3 This test method is useful for research and development,quality control, and specification acceptance.6. Apparatus6.1 Thermomechanical Analyzer (TMA)The essential in-strumentation required to provide the minimum thermome-chanical analytical capability for this test method includes thefollowing:6.
18、1.1 A rigid specimen holder, composed of inert lowexpansivity material #1mm1C1, to center the specimenin the furnace and to fix the specimen to mechanical ground.6.1.2 A rigid circular expansion probe, 2 to 6 mm indiameter, composed of inert low expansivity material #1mm1C1, that contacts the specim
19、en with an applied com-pressive force.6.1.3 A linear sensing element with a nominal range of2-mm capable of measuring the displacement in length of thespecimen readable to within 650 nm.6.1.4 A weight or force transducer to generate a constantforce of 0 to 50 mN that is applied through the rigidcomp
20、ression probe to the specimen.6.1.5 A furnace capable of providing uniform controlledheating (cooling) of a specimen to a constant temperature or ata constant rate over the temperature range of 100 to 600 C.6.1.6 A temperature controller capable of executing a spe-cific temperature program by operat
21、ing the furnace betweenselected temperature limits at a rate of temperature change of5 6 0.5 C/minute.6.1.7 A temperature sensor that can be attached to, incontact with, or reproducibly placed in close proximity to thespecimen to provide an indication of the specimen/furnacetemperature to 60.1 C.6.1
22、.8 A means of sustaining an environment around thespecimen of a dry inert purge gas of 45 to 55 mL/minute.NOTE 1Typically, 99.9+ % pure nitrogen, argon or helium is used.Unless effects of moisture are to be studied, dry purge gas is recommendedand is essential for operation at subambient temperature
23、s.6.1.9 A data collection device, to provide a means ofacquiring, storing, and displaying measured or calculatedsignals, or both. The minimum output signals required forthermomechanical analysis are change in linear dimension,temperature and time.6.2 Micrometer or other measuring device to determine
24、specimen dimensions of up to 8 mm to within 6 of 10 m.7. Hazards7.1 This test method may be used for amorphous andsemicrystalline materials having a glass transition that is at orbelow room temperature providing care is taken to avoidcontacting the specimen with a loaded probe prior to coolingthe sp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME15452011STANDARDTESTMETHODFORASSIGNMENTOFTHEGLASSTRANSITIONTEMPERATUREBYTHERMOMECHANICALANALYSIS

链接地址:http://www.mydoc123.com/p-528904.html