1、Designation: E1543 00 (Reapproved 2011)E1543 14Standard Test Method Practice forNoise Equivalent Temperature Difference of ThermalImaging Systems1This standard is issued under the fixed designation E1543; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the noise equivalent temperature differ
3、ence (NETD; NET) of thermalimaging systems of the conventional forward-looking infrared (FLIR) or other types that utilize an optical-mechanical scanner; itdoes not include charge-coupled devices or pyroelectric vidicons.1.2 Parts of this test method have been formulated under the assumption of a ph
4、otonic detector(s) at a standard backgroundtemperature of 295K (22C). Besides nonuniformity, tests made at other background temperatures may result in impairment ofprecision and bias.1.3 The values stated in SI units are to be regarded as standard.1.4 This standard does not purport to address all of
5、 the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E1213 Practice for Minimum
6、 Resolvable Temperature Difference for Thermal Imaging SystemsE1316 Terminology for Nondestructive Examinations3. Terminology3.1 Definitions:3.1.1 blackbody simulatora device that produces an emission spectrum closely approximating that emitted by a blackbody(surface with emissivity of 1.0), usually
7、 a cavity or a flat plate with a structured or coated surface having a stable and uniformtemperature.3.1.2 dwell timethe time spent, during one frame, in scanning one angular dimension of a single pixel (picture element) ofthe image within the instantaneous field of view (IFOV) of a detector. Thus,
8、for example, if a single pixel is scanned n times duringone frame, the dwell time is given by n times the duration of a single scan of the pixel.3.1.3 FLIRan acronym for forward-looking infrared, originally implying airborne, now denoting any fast-frame thermalimaging system comparable to that of te
9、levision and yielding real-time displays. Generally, these systems employ optical-mechanical scanning mechanisms.3.1.4 See also Section J: Infrared Examination, of Terminology E1316.4. Summary of Test Method4.1 The target is a blackbody source of uniform temperature that is viewed by the infrared th
10、ermal imaging system through anaperture of prescribed size.Aspecified temperature difference is established between the target and its background. Measurementsare made of the peak-to-peak signal voltage from the target and the RMS noise voltage from the background, both across a standardreference fi
11、lter, and of the target and background temperatures. From these measured values, the NETD is calculated.1 This test method practice is under the jurisdiction of ASTM Committee E07 on Nondestructive Testing and is the direct responsibility of Subcommittee E07.10 onSpecialized NDT Methods.Current edit
12、ion approved Dec. 1, 2011Oct. 1, 2014. Published March 2012October 2014. Originally approved in 1993. Last previous edition approved in 20062011 asE1543 - 00(2006).(2011). DOI: 10.1520/E1543-00R11.10.1520/E154314.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Cus
13、tomer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to t
14、he previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright
15、ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Significance and Use5.1 This test method gives an objective measure of the temperature sensitivity of a thermal imaging system (relative to astandard reference filter) exclusive of a monitor, w
16、ith emphasis on the detector(s) and preamplifier.NOTE 1Test values obtained under idealized laboratory conditions may or may not correlate directly with service performance.5.2 This test method affords a convenient means for periodically monitoring the performance of a given thermal imagingsystem.5.
17、3 NETD relates to minimum resolvable temperature difference as described inTest Method E1213.Thus, an increase in NETDmay be manifest as a loss of detail in imagery.5.4 Intercomparisons based solely on NETD figures may be misleading.NOTE 2NETD depends on various factors such as spectral bandwidth an
18、d background temperature.6. Apparatus6.1 The apparatus, as shown in Fig. 1, consists of the following:6.1.1 Blackbody Simulator, temporally stable and controllable to within 0.1C.6.1.2 Target Plate, containing an aperture several times larger dimensionally than the IFOV. The target plate should be a
19、t leastten times the dimension of the aperture in both the height and width. (The plate forms the target background; the aperture, in effect,becomes the target as the blackbody simulator is viewed through it.) The material and surface conditions of the target plate mustbe carefully considered. It is
20、 helpful for the back side of the target plate to be a highly reflective metallic surface to minimize theinfluence of the blackbody simulator on the temperature of the target background. The front surface of the target plate shouldappear to the infrared imaging system to have a high emissivity. One
21、possibility would be to coat the viewed surface with a highemissivity paint or coating.6.1.3 Target Cover, used to block completely the radiation emanating from the target. The target cover should have front andback surface properties similar to those of the target plate.6.1.4 Standard Reference Fil
22、ter, consisting of a single RC low-pass filter whose product RC is equal to twice the dwell time;see Fig. 2.NOTE 3If the resistance, R, is in ohms and the capacitance, C, is in farads, RC is in seconds.NOTE 4The purpose of the filter is to standardize and define a reference noise bandwidth, upon whi
23、ch the noise measurement depends in part.NOTE 5If convenient, the filter may be a self-contained unit for external connection.6.1.5 Infrared Spot Radiometer or equivalent radiometric instrument, calibrated with the aid of a blackbody source to anaccuracy within 0.1C.FIG. 1 Schematic of NETD TestProc
24、edure Configuration; (a) When Measuring Signal and (b) When Measuring NoiseE1543 1426.1.6 Digital Oscilloscope.6.1.7 Digital True RMS Voltmeter, with high crest factor (peak voltage/RMS voltage) so as not to attenuate any noise peaks, andbandwidth from approximately zero to at least 1.6/RC. See 6.1.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME15432014STANDARDPRACTICEFORNOISEEQUIVALENTTEMPERATUREDIFFERENCEOFTHERMALIMAGINGSYSTEMS 成像 系统 噪声

链接地址:http://www.mydoc123.com/p-528902.html