ASTM E1463-1992(2012) Standard Guide for Conducting Static and Flow-Through Acute Toxicity Tests With Mysids From the West Coast of the United States《用美国西海岸糠虾目动物进行静态和无逆流急性毒性试验的标准指南.pdf
《ASTM E1463-1992(2012) Standard Guide for Conducting Static and Flow-Through Acute Toxicity Tests With Mysids From the West Coast of the United States《用美国西海岸糠虾目动物进行静态和无逆流急性毒性试验的标准指南.pdf》由会员分享,可在线阅读,更多相关《ASTM E1463-1992(2012) Standard Guide for Conducting Static and Flow-Through Acute Toxicity Tests With Mysids From the West Coast of the United States《用美国西海岸糠虾目动物进行静态和无逆流急性毒性试验的标准指南.pdf(23页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1463 92 (Reapproved 2012)Standard Guide forConducting Static and Flow-Through Acute Toxicity TestsWith Mysids From the West Coast of the United States1This standard is issued under the fixed designation E1463; the number immediately following the designation indicates the year oforigin
2、al adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide describes procedures for obtaining dataconcerning the
3、adverse effects of a test material (not food)added to marine and estuarine waters on certain species ofmarine and estuarine mysids during 96 h of continuousexposure. Juvenile mysids used in these tests are taken fromcultures shortly after release from the brood and exposed tovarying concentrations o
4、f a toxicant in static or flow-throughconditions. These procedures will be useful for conductingtoxicity tests with other species of mysids, although modifica-tions might be necessary.1.2 Modifications of these procedures might be justified byspecial needs or circumstances. Although using appropriat
5、eprocedures is more important than following prescribedprocedures, results of tests conducted using unusual proceduresare not likely to be comparable to results of many other tests.Comparisons of results obtained using modified and unmodi-fied versions of these procedures might provide useful infor-
6、mation concerning new concepts and procedures for conduct-ing acute tests with other species of mysids.1.3 The procedures given in this guide are applicable tomost chemicals, either individually or in formulations, com-mercial products, and known or unknown mixtures. Withappropriate modifications th
7、ese procedures can be used toconduct acute tests on factors such as temperature, salinity, anddissolved oxygen. These procedures can also be used to assessthe toxicity of potentially toxic discharges such as municipalwastes, oil drilling fluids, produced water from oil wellproduction, and other type
8、s of industrial wastes.1.4 Results of acute toxicity tests with toxicants experimen-tally added to salt and estuarine waters should usually bereported in terms of a LC50 (median lethal concentration).1.5 This guide is arranged as follows:SectionReferenced Documents 2Terminology 3Summary of Guide 4Si
9、gnificance and Use 5Apparatus 6Facilities 6.1Construction Materials 6.2Metering Systems 6.3Test Chambers 6.4Cleaning 6.5Acceptability 6.6Safety Precautions 7Dilution Water 8Requirements 8.1Source 8.2Treatment 8.3Characterization 8.4Test Material 9General 9.1Stock Solution 9.2Test Concentrations 9.3T
10、est Organisms 10Species 10.1Age 10.2Source 10.3Brood Stock 10.4Food 10.5Handling 10.6Harvesting Young 10.7Quality 10.8Procedure 11Experimental Design 11.1Dissolved Oxygen 11.2Temperature 11.3Loading 11.4Salinity 11.5Light 11.6Beginning of Test 11.7Feeding 11.8Duration of Test 11.9Biological Data 11.
11、10Other Measurements 11.11Analytical Methodology 12Acceptability of Test 13Interpretation of Results 14Report 15AppendixesHolmesimysis costata X1Neomysis mercedis X21This guide is under the jurisdiction of ASTM Committee E47 on BiologicalEffects and Environmental Fate and is the direct responsibilit
12、y of SubcommitteeE47.01 on Aquatic Assessment and Toxicology.Current edition approved Dec. 1, 2012. Published January 2013. Originallyapproved in 1992. Last previous edition approved in 2004 as E1463 92 (2004).DOI: 10.1520/E1463-92R12.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700,
13、 West Conshohocken, PA 19428-2959. United States11.6 The values stated in SI units are to be regarded as thestandard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priat
14、e safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in Section 7.2. Referenced Documents2.1 ASTM Standards:2E729 Guide for Conducting Acute Toxicity Tests on TestMaterials with Fishes, Macroinvertebrates,
15、 and Amphib-iansE943 Terminology Relating to Biological Effects and Envi-ronmental FateE1023 Guide for Assessing the Hazard of a Material toAquatic Organisms and Their UsesE1191 Guide for Conducting Life-Cycle Toxicity Tests withSaltwater MysidsE1192 Guide for Conducting Acute Toxicity Tests on Aque
16、-ous Ambient Samples and Effluents with Fishes,Macroinvertebrates, and AmphibiansE1203 Practice for Using Brine Shrimp Nauplii as Food forTest Animals in Aquatic ToxicologyIEEE/ASTM SI 10 American National Standard for Use ofthe International System of Units (SI): The Modern MetricSystem3. Terminolo
17、gy3.1 The terms “must,” “should,” “ may,” “can,” and “might”have very specific meanings in this guide. “Must” is used toexpress the strongest possible recommendation, just short of anabsolute requirement, that is, to state that this test ought to bedesigned to satisfy the specific condition, unless
18、the purpose ofthe test requires a different design. “Must” is only used inconnection with factors that directly relate to the acceptabilityof the test (see Section 13).3.1.1 “Should” is used to state that the specific condition isrecommended and ought to be met if possible. Althoughviolation of one
19、“should” is rarely a serious matter, violation ofseveral will often render the results questionable. Terms suchas “is desirable.” “is often desirable,” and “might be desirable”are used in connection with less important factors.3.1.2 “May” is used to mean “is (are) allowed to,” “can” isused to mean “
20、is (are) able to,” and “might” is used to mean“could possibly.” Thus the classic distinction between “may”and “can” is preserved, and “might” is never used as asynonym for either “may” or “can.”3.2 Definitions:3.2.1 LC50the statistically or graphically derived bestestimate of the concentration of a
21、toxicant added to an aqueoussolution that results in the death of 50 % of the test organismswithin the test period (see Definition E943).3.2.2 For definitions of other terms used in this guide, referto Guide E729, Terminology E943, Guides E1191 and E1192,and Practice E1203. For an explanation of uni
22、ts and symbols,refer to IEEE/ASTM SI 10.4. Summary of Guide4.1 The toxicity of a substance in marine or estuarine waterscan be determined through a 96-h acute static test or aflow-through test. Static tests may be conducted in glass 2-Lfinger bowls or 350-mL finger bowls. Either size finger bowlprov
23、ides a large surface-to-volume ratio and ample horizontalspace to minimize cannibalism. The dishes should be coveredand aerated. Whichever static technique is used, specific dataon the concentration of test material are obtained and analyzedto determine the effect(s) of the toxicant on survival. In
24、theflow-through acute technique, the test solution flows throughthe test chamber on a once-through basis throughout the test.The flow-through test is considered to be more representativeof actual field conditions, but not all laboratories have thecapabilities of conducting this type of test.5. Signi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME146319922012STANDARDGUIDEFORCONDUCTINGSTATICANDFLOWTHROUGHACUTETOXICITYTESTSWITHMYSIDSFROMTHEWESTCOASTOFTHEUNITEDSTATES

链接地址:http://www.mydoc123.com/p-528744.html