ASTM E1453-2014 Standard Guide for Storage of Magnetic Tape Media that Contains Analog or Digital Radioscopic Data《含模拟或数字射线照相数据的磁带媒体存储的标准指南》.pdf
《ASTM E1453-2014 Standard Guide for Storage of Magnetic Tape Media that Contains Analog or Digital Radioscopic Data《含模拟或数字射线照相数据的磁带媒体存储的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1453-2014 Standard Guide for Storage of Magnetic Tape Media that Contains Analog or Digital Radioscopic Data《含模拟或数字射线照相数据的磁带媒体存储的标准指南》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1453 09E1453 14Standard Guide forStorage of Magnetic Tape Media that Contains Analog orDigital Radioscopic Data1This standard is issued under the fixed designation E1453; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide may be used for the control and maintenance of recorded and unrecorded magnetic and optical m
3、edia of analogor digital electronic data from industrial radioscopy.1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.3 This standa
4、rd does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. For specific precautionary stat
5、ements, see Section 6.2. Referenced Documents2.1 ASTM Standards:2E1000 Guide for RadioscopyE1255 Practice for Radioscopy2.2 ANSI Standards:3INCITS 40 Unrecorded Magnetic TapeINCITS 39 Recorded Magnetic TapeINCITS 125 Two-Sided, Double Density DiskINCITS 46 Six-Disk PackINCITS 48 Magnetic Tape Casset
6、tes2.3 NIST Standard:NBS Handbook, NBS SP 500.10143. Significance and Use3.1 The provisions of this guide are intended to control and maintain the quality of recorded industrial electronic data fromradioscopy and unrecorded magnetic and optical media only, and are not intended to control the accepta
7、bility of the materials orproducts examined. It is further intended that this guide be used as an adjunct to Guide E1000 and Practice E1255.3.2 The necessity for applying specific control procedures such as those described in this guide is dependent to a certain extent,on the degree to which the use
8、r adheres to good recording and storage practices as a matter of routine procedure.4. Unrecorded Media Storage4.1 Un-Opened Containers:4.1.1 Storage RecommendationsAny media in containers sealed by the manufacturer and not opened should be stored asshipped, whenever possible, to avoid container dama
9、ge and possible media damage. Storage temperature should be 60 6 20F(16 6 11C), relative humidity range of 45 6 15 %, at a pressure range of 12.5 6 2.5 psi and a maximum magnetic field strength1 This guide is under the jurisdiction of ASTM Committee E07 on Nondestructive Testing and is the direct re
10、sponsibility of Subcommittee E07.01 on Radiology (X andGamma) Method.Current edition approved July 1, 2009Oct. 1, 2014. Published July 2009October 2014. Originally approved in 1992. Last previous edition approved in 20022009 asE1453 - 93E1453 - 09.(2002). DOI: 10.1520/E1453-09.10.1520/E1453-14.2 For
11、 referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from American National Standards Institute (ANSI), 25
12、W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.4 Available from National Institute of Standards and Technology (NIST), 100 Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.This document is not an ASTM standard and is intended only to provide the user of an ASTM
13、standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by
14、 ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1of 50 Oe. The optimum storage conditions are 65F (18C) at 40 % relative humidity, 14.7 psi and a maximum magnetic fieldstrength of 30 Oe.
15、Damaging stresses in the media can be produced by large temperature and humidity variations even if theyremain within the specified ranges. Specific media manufacturers recommendations should be consulted when large variations intemperature or humidity, or both, are anticipated or experienced.4.1.2
16、Higher or Lower Storage ConditionsWhen temperature exceeds 90F (32C) or humidity exceeds 90 %, or pressureexceeds 15 psi, some unrecorded media should be used under normal existing conditions to test for degradation. If degradationis found on these samples, subsequent sampling may be done on other m
17、edia to avoid unnecessary scrap. If storage temperaturefalls below 30F (1C), media stored at these lower temperatures in unopened containers should be allowed to stabilize at a roomtemperature (60 to 90F (16 to 32C) before opening the containers. The stabilization time will vary with the bulk of the
18、 storedmedia and the storage temperature. The lower the temperature and greater the bulk, the longer the time required to reach roomtemperature. If containers are opened too soon, condensation could cause the media to stick to whatever is touching their surfaces.If the relative humidity falls below
19、10 % and the moisture in the media is reduced sufficiently, damage can occur during handlingafter opening the sealed containers, and the media may be subjected to static electrical discharges. Storage humidities over 60 %can also cause the media to stick to whatever is touching their surfaces.4.2 Op
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME14532014STANDARDGUIDEFORSTORAGEOFMAGNETICTAPEMEDIATHATCONTAINSANALOGORDIGITALRADIOSCOPICDATA 模拟

链接地址:http://www.mydoc123.com/p-528716.html