《ASTM E1380-1990(2005) Standard Specification for Color Coding of Laboratory Pipets with Multiple Graduations 0 1 mL and Larger But Excluding Disposable Prothrombin and Disposable M.pdf》由会员分享,可在线阅读,更多相关《ASTM E1380-1990(2005) Standard Specification for Color Coding of Laboratory Pipets with Multiple Graduations 0 1 mL and Larger But Excluding Disposable Prothrombin and Disposable M.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1380 90 (Reapproved 2005)Standard Specification forColor Coding of Laboratory Pipets with MultipleGraduations, 0.1 mL and Larger, But Excluding DisposableProthrombin and Disposable Micropipets1This standard is issued under the fixed designation E 1380; the number immediately following
2、 the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification p
3、rovides a system for color codingdisposable pipets (glass and plastic) with multiple graduations.The color will indicate capacity and subdivisions for identifi-cation purposes.1.2 The intent of this specification is to ensure that whencolor coding is utilized, all manufacturers will be encouragedto
4、use the same color for nominal value identification.2. Referenced Documents2.1 ASTM Standards:2E 1273 Specification for Color Coding of Reusable Labo-ratory Pipets3. General Requirements3.1 Colors shall be as specified in Table 1.3.2 DurabilityDisposable pipet coding shall be as durableas the gradua
5、tions of the pipet. (Any institution or individualwho reuses a disposable product must bear full responsibilityfor its safety and effectiveness).4. Style4.1 Each pipet may be color coded by one or more of thefollowing methods:4.1.1 A single or double color band. The single color bandshall be 6 to 10
6、 mm wide and the double color bands shall be3 to 5 mm wide and separated by a clear space of 2 to 3 mm.Color bands need not be continuous, but may be broken as longas 40 % of the circumference of the pipet is covered.4.1.2 Colored plugging material.4.1.3 Permanent color constituent (ingredient) of t
7、he pipetmaterial(s).4.1.4 Coloring of the standard identification marking(s) ofthe pipet.4.2 A color blow out band or bands shall not be the onlymethod used to signify size.4.3 LocationColor coding shall be near the top end of thepipet. In the instances where a separate band or bands are1This specif
8、ication is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Subcommittee E41.01 onApparatus.Current edition approved May 1, 2005. Published October 2005. Originallyapproved in 1990. Last previous edition approved in 1999 as E 138090(1999)e1.2For
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME138019902005STANDARDSPECIFICATIONFORCOLORCODINGOFLABORATORYPIPETSWITHMULTIPLEGRADUATIONS01MLANDLARGERBUTEXCLUDINGDISPOSABLEPROTHROMBINANDDISPOSABLEMPDF

链接地址:http://www.mydoc123.com/p-528584.html