《ASTM E1345-1998(2014) Standard Practice for Reducing the Effect of Variability of Color Measurement by Use of Multiple Measurements《使用多元测量降低颜色测量变异效应的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1345-1998(2014) Standard Practice for Reducing the Effect of Variability of Color Measurement by Use of Multiple Measurements《使用多元测量降低颜色测量变异效应的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1345 98 (Reapproved 2014)Standard Practice forReducing the Effect of Variability of Color Measurement byUse of Multiple Measurements1This standard is issued under the fixed designation E1345; the number immediately following the designation indicates the year oforiginal adoption or, in
2、 the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONRecent improvements in the precision and bias of color-measuring instruments have b
3、eenaccompanied by more widespread use of numerical color tolerances based on instrumental measure-ments. As tighter tolerances are specified, they begin to approach the limits of visual perception. Inmany cases, the instrument user has found it difficult to prepare and measure specimens with adequat
4、erepeatability. This practice provides procedures for reducing variability in the mean results of colormeasurement by the use of multiple measurements, and it indicates how many measurements arerequired for a specific reduction.1. Scope1.1 Reduction of the variability associated with averagecolor or
5、 color-difference measurements of object-color speci-mens is achieved by statistical analysis of the results ofmultiple measurements on a single specimen, or by measure-ment of multiple specimens, whichever is appropriate.1.2 This practice provides a means for the determination ofthe number of measu
6、rements required to reduce the variabilityto a predetermined fraction of the relevant color or color-difference tolerances.1.3 This practice is general in scope rather than specific asto instrument or material.2. Referenced Documents2.1 ASTM Standards:2D2244 Practice for Calculation of Color Toleran
7、ces andColor Differences from Instrumentally Measured ColorCoordinatesD3134 Practice for Establishing Color and Gloss TolerancesE178 Practice for Dealing With Outlying ObservationsE284 Terminology of AppearanceE308 Practice for Computing the Colors of Objects by Usingthe CIE SystemE456 Terminology R
8、elating to Quality and StatisticsE1164 Practice for Obtaining Spectrometric Data for Object-Color Evaluation2.2 Other Standard:SAE J 1545 Recommended Practice for Instrumental ColorDifference Measurement for Exterior Finishes, Textilesand Colored Trim33. Terminology3.1 Definitions of appearance term
9、s in Terminology E284 orstatistical terms in Terminology E456 are applicable to thispractice.3.2 Definitions of Terms Specific to This Standard:3.2.1 box and whisker plot, na nonparmetric data analysisdiagram that illustrates the 25, 50, and 75 % cumulativedistribution of values in a data set (the b
10、ox) and the expectedrange of values, defined by distance outside the box ends; seewhiskers, see Fig. 1.3.2.2 extreme value, na single reading, selected from aseries of readings, whose value is farther from the nearer boxend than 3.0 times the hinge length.3.2.2.1 DiscussionA box and whiskers plot is
11、 normallyused to find outliers and extreme values. Such values should beeliminated from a series before calculating the series mean,standard deviation, and confidence intervals.3.2.3 hinges, nthe 25 and 75 % cumulative distributionpoints in a set of readings taken during a measurement.3.2.3.1 Discus
12、sionHinges represent the values in which1This practice is under the jurisdiction of ASTM Committee E12 on Color andAppearance and is the direct responsibility of Subcommittee E12.04 on Color andAppearance Analysis.Current edition approved Nov. 1, 2014. Published November 2014. Originallyapproved in
13、1990. Last previous edition approved in 2008 as E1345 98 (2008)1.DOI: 10.1520/E1345-98R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Sum
14、mary page onthe ASTM website.3Available from Society of Automotive Engineers (SAE), 400 CommonwealthDr., Warrendale, PA 15096-0001, http:/www.sae.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States125 % of the readings are less than t
15、he lower hinge and 75 % ofthe readings are less than the upper hinge. See also hingelength.3.2.3.2 DiscussionHinges are sometimes called the lower(Q1) and upper (Q1) quartile values.3.2.4 hinge length, H, nthe range of values between thelower and upper hinges.3.2.4.1 DiscussionThe hinge length is so
16、metimes calledthe box width or the interquartile range Q3to Q1.3.2.5 outlier, na single reading, selected from a series ofreadings, whose value is further from the nearer box end then1.5 times the hinge length; see 3.2.2.1.3.2.6 sampling number, N, nnumber of multiplemeasurements, or number of multi
17、ple specimens, required toreduce the variability of color or color-difference measurementto a desired level.3.2.7 standard deviation of color or color-differencemeasurement, sstandard deviation of the color scale orcolor-difference-scale value, xi, being considered:s 5 $(xi2 xavg!2%/n 2 1!#0.5(1)whe
18、re:xavg=( xi)/n, andn = the number of replicate measurements made.3.2.8 standard deviation of instrument, si,nstandard de-viation of a color-scale or color-difference-scale value due toinstrument variability alone:si5 $(xi2 xavg!2%/n 2 1!#0.5(2)3.2.9 standard error of the estimated mean, se,nstandar
19、ddeviation of color or color-difference measurement divided bythe square root of the sampling number:se5 s/N0.5! (3)3.2.10 standard error goal, se,g,nlevel to which thestandard error of the estimated mean is to be reduced.3.2.11 tolerance, nthe upper tolerance limit minus thelower tolerance limit; t
20、he total allowable range of the color-scale or color-difference-scale value considered.3.2.12 whiskers, nlines extending out from the box endsto the largest and smallest observations lying within 1.5 timesthe hinge length, measured from the box ends.4. Summary of Practice4.1 This practice assumes th
21、at, for the material underconsideration and a specified set of color scales, relevant coloror color-difference tolerances have been established (see Prac-tice D3134).4.2 For convenience, the numerical example in the Appen-dix uses CIELAB LCH (lightness, chroma, hue) color differ-ence scales L*, C*ab
22、, and H*ab(see Practice D2244 andPractice E308), but this is not meant to be restrictive.NOTE 1Some coordinates, such as CIE x, y, Y, do not follow thetheories of this standard due to excessive colinearity. While it has not beentested, this same colinearity problem may also be observed in 1960 u, va
23、nd 1976 u, v coordinates. Table 1 provides a listing of the appropriateand inappropriate color coordinates for use with this practice.4.3 The successive steps in the procedure are as follows:4.3.1 Determine the standard deviation of instrument.4.3.1.1 Screen the measurement data for outliers and ex-
24、treme values.4.3.2 Determine the standard deviation of color or color-difference measurement.4.3.2.1 Screen the measurement data for outliers and ex-treme values.4.3.3 Determine the standard error of the estimated mean fora sampling number of one.4.3.4 Determine the final sampling number that reduce
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME134519982014STANDARDPRACTICEFORREDUCINGTHEEFFECTOFVARIABILITYOFCOLORMEASUREMENTBYUSEOFMULTIPLEMEASUREMENTS

链接地址:http://www.mydoc123.com/p-528482.html