ASTM E1336-2011 Standard Test Method for Obtaining Colorimetric Data From a Visual Display Unit by Spectroradiometry《通过光谱辐射从可见显示器设备获取比色分析数据的标准试验方法》.pdf
《ASTM E1336-2011 Standard Test Method for Obtaining Colorimetric Data From a Visual Display Unit by Spectroradiometry《通过光谱辐射从可见显示器设备获取比色分析数据的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1336-2011 Standard Test Method for Obtaining Colorimetric Data From a Visual Display Unit by Spectroradiometry《通过光谱辐射从可见显示器设备获取比色分析数据的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1336 11Standard Test Method forObtaining Colorimetric Data From a Visual Display Unit bySpectroradiometry1This standard is issued under the fixed designation E1336; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe fundamental procedure for characterizing the color and luminance of a visual display unit(VDU) is to obtai
3、n the spectroradiometric data under specified measurement conditions, and fromthese data to compute CIE chromaticity coordinates and absolute luminance values based on the 1931CIE Standard Observer. The considerations involved and the procedures to be used to obtain precisioncolorimetric data for th
4、is purpose are contained in this test method. The values and procedures forcomputing CIE chromaticity coordinates are contained in Practice E308. The procedures for obtainingspectroradiometric data are contained in Test Method E1341. This test method includes somemodifications to the procedures give
5、n in Practice E308 that are necessary for computing the absoluteluminance values of VDUs. This procedure is intended to be generally applicable to any VDU device,including but not limited to cathode ray tubes (CRT), liquid crystal displays (LCD), and electrolu-minescent displays (ELD).1. Scope1.1 Th
6、is test method prescribes the instrumental measure-ments required for characterizing the color and brightness ofVDUs.1.2 This test method is specific in scope rather than generalas to type of instrument and object.1.3 The values stated in SI units are to be regarded asstandard. No other units of mea
7、surement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory li
8、mitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E284 Terminology of AppearanceE308 Practice for Computing the Colors of Objects byUsing the CIE SystemE1341 Practice for Obtaining Spectroradiometric Data fromRadiant Sources for Colorimetry2.2 CIE Publications:Publication CIE No. 18
9、Principles of Light Measurements3Publication CIE No. 15.2 Colorimetry, 2nd ed., 19863Publication CIE No. 63 Spectroradiometric Measurement ofLight Sources, 198432.3 IEC Publications:Publication No. 441 Photometric and Colorimetric Methodsof Measurement of the Light Emitted by a Cathode-RayTube Scree
10、n, 197443. Terminology3.1 The definitions of appearance terms in TerminologyE284 are applicable to this test method.1This test method is under the jurisdiction of ASTM Committee E12 on Colorand Appearance and is the direct responsibility of Subcommittee E12.06 on ImageBased Color Measurement.Current
11、 edition approved Nov. 1, 2011. Published November 2011. Originallyapproved in 1991. Last previous edition approved in 2003 as E1336 96 (2003).DOI: 10.1520/E1336-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Bo
12、ok of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. National Committee of the CIE (International Commissionon Illumination), C/o Thomas M. Lemons, TLA-Lighting Consultants, Inc., 7 PondSt., Salem, MA 01970, http:/www.cie-usnc.o
13、rg.4Available from International Electrotechnical Commission (IEC), 3 rue deVaremb, Case postale 131, CH-1211, Geneva 20, Switzerland, http:/www.iec.ch.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Summary of Test Method4.1 Proc
14、edures are given for obtaining spectroradiometricdata and for the calculation of CIE tristimulus values and othercolor coordinates to describe the colors of VDUs. Modifica-tions to the standard calculation procedures of Practice E308are described.5. Significance and Use5.1 The most fundamental metho
15、d for obtaining CIE tris-timulus values or other color coordinates for describing thecolors of visual display units (VDUs) is by the use ofspectroradiometric data. (See CIE No. 18 and 63.) These dataare used by summation together with numerical values repre-senting the 1931 CIE Standard Observer and
16、 normalized to Km,the maximum spectral luminous efficacy function.5.2 The special requirements for characterizing VDUs pos-sessing narrow or discontinuous spectra are presented anddiscussed. Modifications to the requirements of Practice E308are given to correct for the unusual nature of narrow ordis
17、continuous sources.6. Requirements When Using Spectroradiometry6.1 When describing the measurement of VDUs by spectro-radiometry, the following must be specified:6.1.1 The radiometric quantity determined, such as theirradiance (W/m2) or radiance (W/m2-sr), or the photometricquantity determined, such
18、 as illuminance (lm/m2) or luminance(lm/m2-sr or cd/m2). The use of older, less descriptive namesor units such as phot, nit, stilb is not recommended.6.1.2 The geometry of the measurement conditions, includ-ing, whether a diffuser was used and the material from whichit was constructed, the distances
19、 from the VDU, the size of thearea to be measured on the VDU, the uniformity of the VDUacross the area to be measured, the microstructure of the VDUpicture elements, and the presence of any special intermediateoptical devices such as integrating spheres.6.1.3 The spectral parameters, including the s
20、pectral region,wavelength measurement interval, and spectral bandwidth.These must be specified since the various VDU technologiesmay demand more or less stringent requirements.6.1.4 The type of standard used to calibrate the system, astandard lamp, a calibrated source, or a calibrated detector, andt
21、he source of the calibration.6.1.5 The physical and temporal characteristics of the VDUincluding, refresh or field rate, convergence and purity adjust-ments (if the manufacturer allows such), luminance level, andany spectral line character in the emission from the VDU. Theintegration time of the det
22、ector system should be noted inrelation to the refresh or field rate of the VDU. (See IEC No.441.)7. Apparatus7.1 The basic instrument requirement is a spectroradiomet-ric system designed for the measurement of spectral radianceor irradiance of light sources. See Practice E1341 for details oneach of
23、 the parts of a spectroradiometer and how to calibrateand use the instrument.7.2 Calibration Sources:7.2.1 The standard calibration source for spectroradiometryis a tungsten-filament lamp operated at a specified current. It ispreferable to have more than one standard lamp to permitcross-checks and t
24、o allow calibration at a range of luminancelevels.7.2.2 Monochromatic emission sources such as a low-pressure mercury arc lamp or tunable laser should also beavailable for use in calibrating the wavelength scale.7.2.3 The electrical supplies for the calibration sourcesshould be of the constant curre
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME13362011STANDARDTESTMETHODFOROBTAININGCOLORIMETRICDATAFROMAVISUALDISPLAYUNITBYSPECTRORADIOMETRY

链接地址:http://www.mydoc123.com/p-528466.html