ASTM E1326-2006 Standard Guide for Evaluating Nonconventional Microbiological Tests Used for Enumerating Bacteria《评估细菌计数的非常规微生物试验标准指南》.pdf
《ASTM E1326-2006 Standard Guide for Evaluating Nonconventional Microbiological Tests Used for Enumerating Bacteria《评估细菌计数的非常规微生物试验标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1326-2006 Standard Guide for Evaluating Nonconventional Microbiological Tests Used for Enumerating Bacteria《评估细菌计数的非常规微生物试验标准指南》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1326 06Standard Guide forEvaluating Nonconventional Microbiological Tests Used forEnumerating Bacteria1This standard is issued under the fixed designation E 1326; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 The purpose of this guide is to assist users and producersof nonconventional tests in determining the applicab
3、ility of thetest for processing different types of samples and evaluating theaccuracy of the results. Conventional procedures such as theHeterotrophic (Standard) Plate Count, the Most ProbableNumber (MPN) method and the Spread Plate Count are widelycited and accepted for the enumeration of microorga
4、nisms.However, these methods have their limitations, such as perfor-mance time and degree of accuracy. It is these limitations thathave recently led to the marketing of a variety of non-conventional procedures, test kits and instruments.1.2 A conventional test is one that is widely accepted andpubli
5、shed as a standard microbiological method or relatedprocedure. A new, nonconventional test method will attempt toprovide the same information through the measurement of adifferent parameter. This guide is designed to assist investiga-tors in assessing the accuracy and precision of nonconventionalmet
6、hods intended for the determination of microbial popula-tion densities or activities.1.3 It is recognized that the Heterotrophic Plate Count doesnot recover all microorganisms present in a product or a system(1, 2).2When this problem occurs during the characterizationof a microbiological population,
7、 alternative standard enumera-tion procedures may be necessary, as in the case of sulfate-reducing bacteria. At other times, chemical methods thatmeasure the rates of appearance of metabolic derivatives or theutilization of contaminated product components might beindicated. In evaluating nonconventi
8、onal tests, the use of thesealternative standard procedures may be the only means avail-able for establishing correlation. In such cases, this guide canserve as a reference for those considerations.1.4 Since there are so many types of tests that could beconsidered nonconventional, it is impossible t
9、o recommend aspecific test protocol with statistical analyses for evaluating thetests. Instead, this guide should assist in determining whattypes of tests should be considered to verify the utility andidentify the limitations of the nonconventional test.2. Referenced Documents2.1 ASTM Standards:3D 3
10、870 Practice for Establishing Performance Characteris-tics for Colony Counting Methods in Microbiology4D 4012 Test Method for Adenosine Triphosphate (ATP)Content of Microorganisms in WaterD 5245 Practice for Cleaning Laboratory Glassware, Plas-ticware, and Equipment Used in Microbiological AnalysesD
11、 5465 Practice for Determining Microbial Colony Countsfrom Waters Analyzed by Plating MethodsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 2250 Method for Determination of Endotoxin Concentra-tion in Water Miscible Metal Working Fluids3. Summary o
12、f Guide3.1 ASTM standard practices are referenced for use byproducers and users to determine the potential utility of thenonconventional test. Users of tests who are unequipped forperforming standard microbiological tests are given recom-mendations for seeking out microbiological laboratories thatco
13、uld perform collaborative studies to evaluate and verify theinformation generated with the nonconventional tests.4. Significance and Use4.1 This guide should be used by producers and potentialproducers of nonconventional tests to determine the accuracy,selectivity, specificity, and reproducibility o
14、f the tests, asdefined in Practices E 691 and D 3870. Results of such studiesshould identify the limitations and indicate the utility orapplicability of the nonconventional test, or both, for use ondifferent types of samples.4.2 Nonconventional test users and potential users shouldemploy this guide
15、to evaluate results of the nonconventional1This guide is under the jurisdiction ofASTM Committee E35 on Pesticides andAlternative Control Agents and is the direct responsibility of Subcommittee E35.15on Antimicrobial Agents.Current edition approved Nov. 1, 2006. Published November 2006. Originallyap
16、proved in 1990. Last previous edition approved in 1998 as E 1326 98.2The boldface numbers in parentheses refer to the list of references at the end ofthis guide.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book o
17、f ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.test as compared to their present methods. Practices D 5245and D 5465 shou
18、ld be reviewed in regards to the conventionalmicrobiological methods employed. If conventional methodshave not been used for monitoring the systems, then guidelinesare included for obtaining microbiological expertise.4.3 Utilization of a nonconventional test may reduce thetime required to determine
19、the microbiological status of thesystem and enable an improvement in the overall operatingefficiency. In many cases, the findings of a significantly highlevel of bacteria indicates the need for an addition of anantimicrobial agent. By accurately determining this in a shortertime period than by conve
20、ntional methods, treatment withantimicrobial agents may circumvent more serious problemsthan if the treatment were postponed until conventional resultswere available. If the antimicrobial treatment program relies onan inaccurate nonconventional test, then unnecessary loss ofproduct and problems asso
21、ciated with inappropriate selectionor improper dosing with antimicrobial agents would exist.4.4 Since many methods based on entirely different chemi-cal and microbiological principles are considered, it is notpossible to establish a unique design and recommend a specificmethod of statistical analyse
22、s for the comparisons to be made.It is only possible to present guides that should be followedwhile performing the experiments. It is also recommended thata statistician be involved in the study.5. Procedures5.1 In order to determine the utility of the nonconventionaltest, evaluate and compare the r
23、esults to those obtained with apreviously accepted standard method. The Heterotrophic PlateCount (Practice D 5465) may be entirely satisfactory for thispurpose (3); however, understand its limitations before it isused as the basis for evaluating methods that measure otherparameters indicative of mic
24、robial life (metabolic activity,concentration of cell constituents, or whole cell numbers).Several methods used for the Heterotrophic Plate Count arelisted in Table 1. When the Heterotrophic Plate Count is not asuitable refereed method, Adenosine Triphosphate Concentra-tion (Test Method D 4012), End
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME13262006STANDARDGUIDEFOREVALUATINGNONCONVENTIONALMICROBIOLOGICALTESTSUSEDFORENUMERATINGBACTERIA

链接地址:http://www.mydoc123.com/p-528441.html