ASTM E1323-2015 Standard Guide for Evaluating Laboratory Measurement Practices and the Statistical Analysis of the Resulting Data《评估实验室测量规程和结果数据统计分析的标准指南》.pdf
《ASTM E1323-2015 Standard Guide for Evaluating Laboratory Measurement Practices and the Statistical Analysis of the Resulting Data《评估实验室测量规程和结果数据统计分析的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1323-2015 Standard Guide for Evaluating Laboratory Measurement Practices and the Statistical Analysis of the Resulting Data《评估实验室测量规程和结果数据统计分析的标准指南》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1323 09E1323 15 An American National StandardStandard Guide forEvaluating Laboratory Measurement Practices and theStatistical Analysis of the Resulting Data1This standard is issued under the fixed designation E1323; the number immediately following the designation indicates the year of
2、original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers key elements of an evaluation of a labora
3、torys measurement practices and the statistical analysis of theresulting data. This guide addresses an evaluation that covers a broad range of in-house quality measurements, some of which maybe directly related to accreditation requirements.1.2 This guide describes provides an overview of the docume
4、ntation needed to verify the operation of the practices, and whatparts of the data, to test and interpret to verify for verification and monitoring of the practices used in the laboratory formeasurement. In addition, it guides the user in verifying that the extent of documentation and the quality of
5、 statistical evaluationsperformed on the data being generated by the laboratory.is sufficient. The user is advised to fully document all work covered bythe scope of this guide as a general principle of laboratory practice and for audit purposes, whether internal or external.1.3 This guide does not s
6、pecify or provide guidance for the establishment or assessment of a quality program. is not designedto be exhaustive for all aspects of work realized under its scope. The user is encouraged to thoroughly realize (achieve in practice)the principles set forth in this guide, consulting other relevant s
7、tandards and industry documents when appropriate.2. Referenced Documents2.1 ASTM Standards:2E177 Practice for Use of the Terms Precision and Bias in ASTM Test MethodsE178 Practice for Dealing With Outlying ObservationsE456 Terminology Relating to Quality and StatisticsE691 Practice for Conducting an
8、 Interlaboratory Study to Determine the Precision of a Test MethodE1169 Practice for Conducting Ruggedness TestsE2554 Practice for Estimating and Monitoring the Uncertainty of Test Results of a Test Method Using Control Chart TechniquesE2587 Practice for Use of Control Charts in Statistical Process
9、ControlE2655 Guide for Reporting Uncertainty of Test Results and Use of the Term Measurement Uncertainty in ASTM Test Methods2.2 ISO Standard:ISO 90009001 Quality Management and Quality Assurance Standards3ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories3
10、2.3 Other Standard:ILAC/ISO Laboratory Accreditation Principles and PracticeCollected Reports 1979198343. Terminology3.1 Terms are defined in Terminology E456.4. Significance and Use4.1 This guide is intended to provide guidance for an assessor to evaluate laboratory quality managers, accrediting bo
11、dies andassessors in evaluating the measurement practices of laboratories, a laboratory, the protocol for statistically analyzing the resultingdata from these practices, and the statistical results from these practices.1 This guide is under the jurisdiction ofASTM Committee E11 on Quality and Statis
12、tics and is the direct responsibility of Subcommittee E11.20 on Test Method Evaluationand Quality Control.Current edition approved June 15, 2009April 1, 2015. Published August 2009May 2015. Originally approved in 1989. Last previous edition approved in 20022009 asE1323 98 (2002).E1323 09. DOI: 10.15
13、20/E1323-09.10.1520/E1323-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM sta
14、ndard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cas
15、es only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2 This guide is generic in the sense that it covers the entire range of in-hou
16、se quality measurement practices found in a testinglaboratory, butand the results of the described evaluation may be used by accrediting agencies if for assessment purposes todetermine whether their requirements can be satisfied through the laboratorys existing quality data.data program.4.3 It is no
17、t the intent of this guide to serve as sole criterion for evaluating and accrediting laboratories. It is not intended tocover the important generic guidelines for evaluating the laboratorys quality program, which are contained in ISO/IEC 17025 andother equivalent standards.Evaluation of measurement
18、practices is only one aspect in a comprehensive quality program.5. Purpose of Evaluating Measurement Practices and the Statistical Analysis of the Resulting Data5.1 Data generated from the measurement practices of a laboratory are evaluated to determine its capability to obtain accurateand precise d
19、ata,bias and precision performance, and to determine if the laboratory correctly and efficiently analyzes and reactsto its own data.6. Documentation of Measurement Practices and the Statistical Protocol for Analyzing the Resulting Data6.1 Documentation Relative to Calibration:6.1.1 The material to b
20、e measured should be documented together with its source, expiration or shelf-life date, the accuracy andits source, and accuracy, and any preparations or conditions required which are specific to this material before it can be utilizedas a calibration material. Any additional components, reagents,
21、or physical sources used along with this material, which couldpotentially alter the reliability of the material, should also be documented.6.1.2 The identification of the equipment used, together with the date and operator responsible for the run, and any preparationsinvolved with the calibration ru
22、n should be documented.6.1.3 The type of data representation to be used, including the exact number of data points to be used in the computation of anaverage, standard deviation, or range, as well as how and when these data points are to be generated should be documented. Thisrequires information re
23、garding testing of replicates, duplicates, or single runs tested on one day, a series of days, or a specific timeinterval to be clearly stated for each set of data.6.1.4 The mathematical formula for obtaining control limits, the frequency of computing new limits together with rules ofacceptability o
24、f the new limits, should be documented whenever control limits are applied to a chart.6.1.5 The corrective action taken whenever data points indicate that an out of control condition exists, or whenever trendanalysis indicates a change or shift in the instrument response should be recorded.6.1.6 A t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME13232015STANDARDGUIDEFOREVALUATINGLABORATORYMEASUREMENTPRACTICESANDTHESTATISTICALANALYSISOFTHERESULTINGDATA

链接地址:http://www.mydoc123.com/p-528433.html