ASTM E1320-2010 Standard Reference Radiographs for Titanium Castings《钛铸件用标准参考射线照片》.pdf
《ASTM E1320-2010 Standard Reference Radiographs for Titanium Castings《钛铸件用标准参考射线照片》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1320-2010 Standard Reference Radiographs for Titanium Castings《钛铸件用标准参考射线照片》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1320 10Standard Reference Radiographs forTitanium Castings1This standard is issued under the fixed designation E1320; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses
2、indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 The reference radiographs provided in the adjunct to thisstandard are reprod
3、uctions of original radiographs and aresupplied as a means for establishing some of the categories andseverity levels of discontinuities in titanium castings that maybe revealed by radiographic examination. Use of this standardfor the specification or grading of castings requires procure-ment of the
4、 adjunct reference radiographs which illustrate thediscontinuity types and severity levels. They should be used inaccordance with contractual specifications.NOTE 1The original radiographs produced for Volume I were takenwith X-rays in the range of 110 KV to 220 KV. The original radiographsproduced f
5、or Volume II were taken with X-rays in the range of 200 K to340 KV.1.2 These film reference radiographs are not intended toillustrate the types and degrees of discontinuities found intitanium castings when performing digital radiography. Ifperforming digital radiography of titanium castings, refer t
6、oDigital Reference Image Standard E2669.1.3 These reference radiographs consist of two volumes.Volume I, described in Table 1, is applicable to a wall thicknessof up to 1 in. (0 to 25.4 mm). Volume II, described in Table 2,is applicable to a wall thickness of over 1 in. to 2 in. (25.4 mmto 50.8 mm).
7、 The standard may be used, where there is no otherapplicable standard, for other thicknesses for which agreementhas been reached between purchaser and manufacturer.NOTE 2The reference radiographs are not impacted by this revision.There have been no revisions to the adjunct reference radiographs sinc
8、eoriginal issue. The adjunct reference radiographs of any issue remain validand may be used to this standard.1.4 The plates produced to serve for use in this standardwere purposely cast to exhibit the desired discontinuity. Theplates were cast using different processes as shown in Table 1and Table 2
9、. Hot isostatic pressing was not used on any of theplates.1.5 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are mathemati-cal conversions to SI units that are provided for informationonly and are not considered standard.1.6 This standard doe
10、s not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Stan
11、dards:2E94 Guide for Radiographic ExaminationE1316 Terminology for Nondestructive ExaminationsE2669 Digital Reference Images for Titanium Castings2.2 ASTM Adjuncts:Reference Radiographs for the Inspection of Titanium Cast-ingsVolume I, applicable up to 1 in. (25.4 mm)3,4Volume II, applicable over 1
12、in. to 2 in. (25.4 mm to 50.8mm)4,53. Terminology3.1 DefinitionsFor definitions of terms used in this stan-dard, see Terminology E1316.4. Significance and Use4.1 These reference radiographs are designed so that accep-tance standards, which may be developed for particular re-quirements, can be specif
13、ied in terms of these radiographs. Theradiographs are of castings that were produced under condi-tions designed to produce the discontinuities. The reference1This standard is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.
14、02 onReference Radiological Images.Current edition approved Sept. 1, 2010. Published September 2010. Originallyapproved in 1990. Last previous edition approved in 2005 as E1320 - 05. DOI:10.1520/E1320-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Se
15、rvice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from ASTM International Headquarters. Order Reference Radio-graph No. RRE132001.4Volumes I and II are available from ASTM International Headquarte
16、rs as a set.Order Reference Radiographs RRE1320CS.5Available from ASTM International Headquarters. Order Reference Radio-graph No. RRE132002.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.radiographs are intended to be used for cast
17、ing thicknessranges in accordance with Table 1 and Table 2.5. Description of Discontinuities5.1 This section is provided to aid in the identification andclassification of discontinuities. It briefly describes the radio-graphic appearance of those discontinuities in the referenceradiograph adjuncts a
18、nd indicates their probable cause intitanium. The radiographic appearance of different discontinui-ties can at times be very similar. Therefore, care should alwaysbe taken during the process of identification. In extreme casesother methods of identification, either nondestructive or de-structive, ma
19、y need to be employed to obtain positive identi-fication.5.1.1 GasGas in its various forms is usually caused by thereaction of molten titanium with the mold or residual materialleft in the mold. Gas tends to migrate to the upper portions ofthe casting. The formation of clustered or scattered gas hol
20、esresults from the generation of larger amounts of gas than asingle gas hole. Whether the larger amount of gas spreads outor is confined to a small area is dependent upon a number offactors including casting process, reaction area, solidificationrate, wall thickness, and geometry.5.1.1.1 Gas holeA s
21、pherical void formed through therelease and subsequent entrapment of gas during solidification.A gas hole will appear as a dark round spot on the radiograph.5.1.1.2 Clustered gas holesAclosely nested group of darkround voids concentrated within a self-defined boundary area.5.1.1.3 Scattered gas hole
22、sMultiple voids appearing asdark round spots on the radiograph. They are randomly spreadthroughout a part or area of a part to a lesser concentration thanclustered gas holes but with the potential to degrade the castingthrough their interaction which precludes their evaluation on anindividual basis.
23、5.1.2 ShrinkageWhile at times the appearance of shrink-age in titanium may be radiographically similar to shrinkage insteel, the faster solidification rate of titanium has a dramaticeffect on the conditions under which each shrinkage type willoccur in titanium. Other factors which influence the form
24、ationof shrinkage are wall thickness and thickness transition gradi-ents, gate size and orientation, mold design, casting configu-ration, metal/mold temperature, and pouring rate and method.All the types of shrinkage described in 5.1.2.1 through 5.1.2.3have a degree of overlap. However, each is most
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME13202010STANDARDREFERENCERADIOGRAPHSFORTITANIUMCASTINGS 铸件 标准 参考 射线 照片 PDF

链接地址:http://www.mydoc123.com/p-528424.html