ASTM E1219-2005 Standard Test Method for Fluorescent Liquid Penetrant Examination Using the Solvent-Removable Process《用溶剂可回收工艺技术进行荧光液渗透检验的标准试验方法》.pdf
《ASTM E1219-2005 Standard Test Method for Fluorescent Liquid Penetrant Examination Using the Solvent-Removable Process《用溶剂可回收工艺技术进行荧光液渗透检验的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1219-2005 Standard Test Method for Fluorescent Liquid Penetrant Examination Using the Solvent-Removable Process《用溶剂可回收工艺技术进行荧光液渗透检验的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1219 05Standard Test Method forFluorescent Liquid Penetrant Examination Using theSolvent-Removable Process1This standard is issued under the fixed designation E 1219; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method2covers procedures for fluorescentpenetrant examination utilizing the solvent-removable pr
3、ocess.It is a nondestructive testing method for detecting discontinui-ties that are open to the surface, such as cracks, seams, laps,cold shuts, laminations, isolated porosity, through leaks, or lackof fusion and is applicable to in-process, final, and maintenanceexamination. It can be effectively u
4、sed in the examination ofnonporous, metallic materials, both ferrous and nonferrous,and of nonmetallic materials such as glazed or fully densifiedceramics and certain nonporous plastics and glass.1.2 This test method also provides a reference:1.2.1 By which a fluorescent penetrant examination solven
5、t-removable process recommended or required by individualorganizations can be reviewed to ascertain its applicability andcompleteness.1.2.2 For use in the preparation of process specificationsdealing with the fluorescent solvent-removable liquid penetrantexamination of materials and parts. Agreement
6、 by the pur-chaser and the manufacturer regarding specific techniques isstrongly recommended.1.2.3 For use in the organization of the facilities andpersonnel concerned with the liquid penetrant examination.1.3 This test method does not indicate or suggest standardsfor evaluation of the indications o
7、btained. It should be pointedout, however, that indications must be interpreted or classifiedand then evaluated. For this purpose there must be a separatecode or specification or a specific agreement to define the type,size, location, and direction of indications considered accept-able, and those co
8、nsidered unacceptable.1.4 All areas of this document may be open to agreementbetween the cognizant engineering organization and the sup-plier, or specific direction from the cognizant engineeringorganization.1.5 This standard does not purport to address all of thesafety concerns, if any, associated
9、with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D 129 Test Method for Sulfur in Petroleum Products (Gen-eral Bom
10、b Method)D 516 Test Methods for Sulfate Ion in WaterD 808 Test Method for Chlorine in New and Used Petro-leum Products (Bomb Method)D 1552 Test Method for Sulfur in Petroleum Products(High-Temperature Method)E 165 Test Method for Liquid Penetrant ExaminationE 433 Reference Photographs for Liquid Pen
11、etrant Inspec-tionE 543 Practice for Evaluating Agencies that Perform Non-destructive TestingE 1316 Terminology for Nondestructive Examinations2.2 ASNT Documents:Recommended Practice SNT-TC-1A Personnel Qualifica-tion and Certification in Nondestructive Testing4ANSI/ASNT-CP-189 Qualification and Cer
12、tification ofNDT Personnel42.3 Military Standard:5MIL-STD-410 Nondestructive Testing Personnel Qualifica-tion and Certification2.4 AIA Standard:1This test method is under the jurisdiction of ASTM Committee E07 onNondestructive Testing and is the direct responsibility of Subcommittee E07.03 onLiquid
13、Penetrant and Magnetic Particle Methods.Current edition approved January 1, 2005. Published January 2005. Originallyapproved in 1987. Last previous edition approved in 1999 as E 1219 - 99.2For ASME Boiler and Pressure Vessel Code applications see related TestMethod SE-1219 in Section II of that Code
14、.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from TheAmerican Society for Nondestructive Testi
15、ng (ASNT), P.O.Box 28518, 1711 Arlingate Lane, Columbus, OH 43228-0518.5Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-295
16、9, United States.NAS 410 Certification and Qualification of NondestructiveTest Personnel62.5 Department of Defense (DoD) ContractsUnless oth-erwise specified, the issue of the documents that are DoDadopted are those listed in the issue of the DoDISS (Depart-ment of Defense Index of Specifications an
17、d Standards) citedin the solicitation.2.6 Order of PrecedenceIn the event of conflict betweenthe text of this test method and the references cited herein, thetext of this test method takes precedence.3. Terminology3.1 Definitionsdefinitions relating to liquid penetrant ex-amination, which appear in
18、Terminology E 1316, shall apply tothe terms used in this test method.4. Summary of Test Method4.1 Aliquid, fluorescent penetrant is applied evenly over thesurface being tested and allowed to enter open discontinuities.After a suitable dwell time, the excess surface penetrant isremoved and the surfac
19、e is dried prior to the application of anonaqueous, wet, or liquid film developer. If an aqueousdeveloper is to be employed, the developer is applied prior tothe drying step. The developer draws the entrapped penetrantout of the discontinuity, staining the developer. The surface isthen examined visu
20、ally under black light to determine presenceor absence of indications. (WarningFluorescent penetrantexamination shall not follow a visible penetrant examinationunless the procedure has been qualified in accordance with 9.2,because visible dyes may cause deterioration or quenching offluorescent dyes.
21、)NOTE 1The developer may be omitted by agreement between pur-chaser and supplier.4.2 Processing parameters, such as precleaning, penetrationtime, etc., are determined by the specific materials used, thenature of the part under examination (that is, size, shape,surface condition, alloy), type of disc
22、ontinuities expected, etc.5. Significance and Use5.1 Liquid penetrant examination methods indicate the pres-ence, location, and, to a limited extent, the nature and magni-tude of the detected discontinuities. This test method isintended primarily for portability and for localized areas ofexamination
23、, utilizing minimal equipment, when a higher levelof sensitivity than can be achieved using visible process isrequired. Surface roughness may be a limiting factor. If so, analternative process such as post-emulsified penetrant should beconsidered, when grinding or machining is not practical.6. Reage
24、nts and Materials6.1 Fluorescent Solvent-Removable Liquid Penetrant Ex-amination Materials, (see Note 2) consist of a family ofapplicable fluorescent penetrants, solvent removers, as recom-mended by the manufacturer, and are classified as Type IFluorescent, Method CSolvent-Removable. Intermixing ofm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME12192005STANDARDTESTMETHODFORFLUORESCENTLIQUIDPENETRANTEXAMINATIONUSINGTHESOLVENTREMOVABLEPROCESS

链接地址:http://www.mydoc123.com/p-528194.html