ASTM E1209-2005 Standard Test Method for Fluorescent Liquid Penetrant Examination Using the Water-Washable Process《用水洗工艺技术进行荧光液渗透检验的标准试验方法》.pdf
《ASTM E1209-2005 Standard Test Method for Fluorescent Liquid Penetrant Examination Using the Water-Washable Process《用水洗工艺技术进行荧光液渗透检验的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1209-2005 Standard Test Method for Fluorescent Liquid Penetrant Examination Using the Water-Washable Process《用水洗工艺技术进行荧光液渗透检验的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1209 05Standard Test Method forFluorescent Liquid Penetrant Examination Using the Water-Washable Process1This standard is issued under the fixed designation E 1209; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method2covers procedures for water-washablefluorescent penetrant examination of materials. It is a
3、 nonde-structive testing method for detecting discontinuities that areopen to the surface such as cracks, seams, laps, cold shuts,laminations, isolated porosity, through leaks, or lack of poros-ity and is applicable to in-process, final, and maintenanceexamination. It can be effectively used in the
4、examination ofnonporous, metallic materials, both ferrous and nonferrous,and of nonmetallic materials such as glazed or fully densifiedceramics and certain nonporous plastics and glass.1.2 This test method also provides a reference:1.2.1 By which a fluorescent penetrant examination methodusing the w
5、ater-washable process recommended or required byindividual organizations can be reviewed to ascertain itsapplicability and completeness.1.2.2 For use in the preparation of process specificationsdealing with the water-washable fluorescent penetrant exami-nation of materials and parts. Agreement by th
6、e purchaser andthe manufacturer regarding specific techniques is stronglyrecommended.1.2.3 For use in the organization of the facilities andpersonnel concerned with the liquid penetrant examination.1.3 This test method does not indicate or suggest standardsfor evaluation of the indications obtained.
7、 It should be pointedout, however, that indications must be interpreted or classifiedand then evaluated. For this purpose there must be a separatecode or specification or a specific agreement to define the type,size, location, and direction of indications considered accept-able, and those considered
8、 unacceptable.1.4 The values stated in inch-pound units are to be regardedas the standard. SI units are provided for information only.1.5 All areas of this document may be open to agreementbetween the cognizant engineering organization and the sup-plier, or specific direction from the cognizant engi
9、neeringorganization.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to
10、 use.2. Referenced Documents2.1 ASTM Standards:3D 129 Test Method for Sulfur in Petroleum Products (Gen-eral Bomb Method)D 516 Test Methods for Sulfate Ion in WaterD 808 Test Method for Chlorine in New and Used Petro-leum Products (Bomb Method)D 1552 Test Method for Sulfur in Petroleum Products(High
11、-Temperature Method)E 165 Test Method for Liquid Penetrant ExaminationE 433 Reference Photographs for Liquid Penetrant Inspec-tionE 543 Practice for Evaluating Agencies that Perform Non-destructive TestingE 1316 Terminology for Nondestructive Examinations2.2 ASNT Documents:Recommended Practice SNT-T
12、C-1A Personnel Qualifica-tion and Certification in Nondestructive Testing4ANSI/ASNT-CP-189 Qualification and Certification ofNDT Personnel42.3 Military Standard:5MIL-STD-410 Nondestructive Testing Personnel Qualifica-tion and Certification2.4 AIA Standard:NAS 410 Certification and Qualification of N
13、ondestructiveTest Personnel62.5 Department of Defense (DoD) ContractsUnless oth-erwise specified, the issue of the documents that are DoD1This test method is under the jurisdiction of ASTM Committee E07 onNondestructive Testing and is the direct responsibility of Subcommittee E07.03 onLiquid Penetra
14、nt and Magnetic Particle Methods.Current edition approved January 1, 2005. Published January 2005. Originallyapproved in 1987. Last previous edition approved in 1999 as E 1209 - 99.2For ASME Boiler and Pressure Vessel Code applications see related TestMethod SE-1209 in Section II of that Code.3For r
15、eferenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from TheAmerican Society for Nondestructive Testing (ASN
16、T), P.O.Box 28518, 1711 Arlingate Lane, Columbus, OH 43228-0518.5Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.6Available from the Aerospace Industries Association of America, Inc., 1250Eye Street, N.W., Washington,
17、DC 20005.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.adopted are those listed in the issue of the DoDISS (Depart-ment of Defense Index of Specifications and Standards) citedin the solicitation.2.6 Order of PrecedenceIn the event
18、of conflict betweenthe text of this test method and the references cited herein, thetext of this test method takes precedence.3. Terminology3.1 Definitionsdefinitions relating to liquid penetrant ex-amination, which appear in Terminology E 1316, shall apply tothe terms used in this test method.4. Su
19、mmary of Test Method4.1 A liquid penetrant is applied evenly over the surfacebeing tested and allowed to enter open discontinuities. After asuitable dwell time, the excess surface penetrant is removedwith water and the surface is dried prior to the application of adry or nonaqueous developer. A deve
20、loper is then applied,drawing the entrapped penetrant out of the discontinuity andstaining the developer. If an aqueous developer is to beemployed, the developer is applied prior to the drying step. Thetest surface is then examined visually under black light in adarkened area to determine the presen
21、ce or absence of indica-tions. (WarningFluorescent penetrant examination shall notfollow a visible penetrant examination unless the procedure hasbeen qualified in accordance with 9.2, because visible dyesmay cause deterioration or quenching of fluorescent dyes.)NOTE 1The developer may be omitted by
22、agreement between pur-chaser and supplier.4.2 The selection of particular water-washable penetrantprocess parameters depends upon the nature of the application,condition under which the examination is to be performed,availability of processing equipment, and type of materials toperform the examinati
23、on. (WarningA controlled method forapplying water and disposing of the water is essential.)4.3 Processing parameters, such as precleaning, penetrationtime and wash times, are determined by the specific materialsused, the nature of the part under examination, (that is, size,shape, surface condition,
24、alloy) and type of discontinuitiesexpected.5. Significance and Use5.1 Liquid penetrant examination methods indicate the pres-ence, location, and, to a limited extent, the nature and magni-tude of the detected discontinuities. This method is normallyused for production inspection of large volumes of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME12092005STANDARDTESTMETHODFORFLUORESCENTLIQUIDPENETRANTEXAMINATIONUSINGTHEWATERWASHABLEPROCESS 水洗

链接地址:http://www.mydoc123.com/p-528163.html