ASTM E1164-2007 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation《用光谱测得的数据评定物体颜色的标准实施规程》.pdf
《ASTM E1164-2007 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation《用光谱测得的数据评定物体颜色的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1164-2007 Standard Practice for Obtaining Spectrometric Data for Object-Color Evaluation《用光谱测得的数据评定物体颜色的标准实施规程》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1164 07Standard Practice forObtaining Spectrometric Data for Object-Color Evaluation1This standard is issued under the fixed designation E 1164; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe fundamental procedure for evaluating the color of a reflecting or transmitting object is to obtainspectrometric data for spe
3、cified illuminating and viewing conditions, and from these data to computetristimulus values based on a CIE (International Commission on Illumination) standard observer anda CIE standard illuminant. The considerations involved and the procedures used to obtain precisespectrometric data are contained
4、 in this practice. The values and procedures for computing CIEtristimulus values from spectrometric data are contained in Practice E 308. Considerations regardingthe selection of appropriate illuminating and viewing geometries are contained in Guide E 179.1. Scope1.1 This practice covers the instrum
5、ental measurement re-quirements, calibration procedures, and material standardsneeded to obtain precise spectral data for computing the colorsof objects.1.2 This practice lists the parameters that must be specifiedwhen spectrometric measurements are required in specificmethods, practices, or specifi
6、cations.1.3 Most sections of this practice apply to both spectrom-eters, which can produce spectral data as output, and spectro-colorimeters, which are similar in principle but can produceonly colorimetric data as output. Exceptions to this applicabil-ity are noted.1.4 This practice is limited in sc
7、ope to spectrometers andspectrometric colorimeters that employ only a single mono-chromator. This practice is general as to the materials to becharacterized for color.1.5 This standard does not purport to address the safetyconcerns, if any, associated with its use. It is the responsibilityof the use
8、r of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1003 Test Method for Haze and Luminous Transmittanceof Transparent PlasticsE 179 Guide for Selection of Geometric
9、Conditions forMeasurement of Reflection and Transmission Properties ofMaterialsE 259 Practice for Preparation of Pressed Powder WhiteReflectance Factor Transfer Standards for Hemisphericaland Bi-Directional GeometriesE 275 Practice for Describing and Measuring Performanceof Ultraviolet, Visible, and
10、 Near-Infrared Spectrophotom-etersE 284 Terminology of AppearanceE 308 Practice for Computing the Colors of Objects byUsing the CIE SystemE 387 Test Method for Estimating Stray Radiant PowerRatio of Dispersive Spectrophotometers by the OpaqueFilter MethodE 805 Practice for Identification of Instrume
11、ntal Methods ofColor or Color-Difference Measurement of MaterialsE 925 Practice for Monitoring the Calibration ofUltraviolet-Visible Spectrophotometers whose SpectralSlit Width does not Exceed 2 nmE 958 Practice for Measuring Practical Spectral Bandwidthof Ultraviolet-Visible SpectrophotometersE 991
12、 Practice for Color Measurement of FluorescentSpecimens Using the One-Monochromator MethodE 1767 Practice for Specifying the Geometries of Observa-tion and Measurement to Characterize the Appearance ofMaterialsE 2153 Practice for Obtaining Bispectral Photometric Datafor Evaluation of Fluorescent Col
13、orE 2194 Practice for Multiangle Color Measurement ofMetal Flake Pigmented Materials2.2 NIST Publications:1This practice is under the jurisdiction of ASTM Committee E12 on Color andAppearance and is the direct responsibility of Subcommittee E12.02 on Spectro-photometry and Colorimetry.Current editio
14、n approved July 15, 2007. Published July 2007. Originallyapproved in 1987. Last previous edition approved in 2002 as E 1164 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information
15、, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.LC-1017 Standards for Checking the Calibration of Spec-trophotometers3TN-594-12 Optical Radiation Measurements: The Tra
16、nslu-cent Blurring EffectMethod of Evaluation and Estima-tion3SP-260-66 Didymium Glass Filters for Calibrating theWavelength Scale of SpectrophotometersSRM 2009,2010, 2013, and 20143SP-692 Transmittance MAP Service32.3 CIE Publications:CIE No. 15.2 Colorimetry, 2nd edition4CIE No. 38 Radiometric and
17、 Photometric Characteristics ofMaterials and Their Measurement4CIE No. 46 Review of Publications on Properties andReflection Values of Material Reflection Standards4CIE No. 51 Method for Assessing the Quality of DaylightSimulators for Colorimetry4CIE No. 130 Practical Applications of Reflectance and
18、Transmittance Measurements42.4 ISO Publications:ISO 2469 Paper, Board and Pulps Measurement ofDiffuse Reflectance Factor52.5 ISCC Publications:Technical Report 2003-1 Guide to Material Standards andTheir Use in Color Measurement53. Terminology3.1 DefinitionsThe definitions contained in TerminologyE
19、284 are applicable to this practice.3.2 Definitions of Terms Specific to This Standard:3.2.1 influx, nthe cone of light rays incident upon thespecimen from the illuminator in a color measuring instrument(see Practice E 1767).3.2.2 efflux, nthe cone of light rays reflected or transmit-ted by a specim
20、en and collected by the receiver in a colormeasuring instrument (see Practice E 1767).3.2.3 regular transmittance factor, Tr, nthe ratio of theflux transmitted by a specimen and evaluated by a receiver tothe flux passing through the same optical system and evaluatedby the receiver when the specimen
21、is removed from the system.3.2.3.1 DiscussionIn some cases, this quantity is practi-cally identical to the transmittance, but it may differ consider-ably. It exceeds unity if the system is such that the specimencauses more light to reach the receiver than would in itsabsence.4. Summary of Practice4.
22、1 Procedures are given for selecting the types and oper-ating parameters of spectrometers used to provide data for thecalculation of CIE tristimulus values and other color coordi-nates to document the colors of objects. The important steps inthe calibration of such instruments, and the material stan
23、dardsrequired for these steps, are described. Guidelines are given forthe selection of specimens to minimize the specimens contri-bution to the measurement imprecision. Parameters are identi-fied that must be specified when spectrometric measurementsare required in specific test methods or other doc
24、uments.5. Significance and Use5.1 The most general and reliable methods for obtainingCIE tristimulus values or, through transformation of them,other coordinates for describing the colors of objects are by theuse of spectrometric data. Colorimetric data are obtained bycombining object spectral data w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME11642007STANDARDPRACTICEFOROBTAININGSPECTROMETRICDATAFOROBJECTCOLOREVALUATION 用光 数据 评定 物体 颜色 标准

链接地址:http://www.mydoc123.com/p-528053.html