1、Designation: E1154 14Standard Specification forPiston or Plunger Operated Volumetric Apparatus1This standard is issued under the fixed designation E1154; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers requirements, operatingconditions, and test methods for piston or plunger operatedvolumetric apparatus (POVA)
3、.1.2 This specification includes specifications applicable forall types of POVA or those given by the manufacturer. Thefollowing precautionary caveat pertains only to the test methodportion, Section 13, of this specification: This standard doesnot purport to address all of the safety concerns, if an
4、y,associated with its use. It is the responsibility of the user of thisstandard to establish appropriate safety and health practicesand determine the applicability of regulatory limitations priorto use.2. Referenced Documents2.1 ASTM Standards:E617 Specification for Laboratory Weights and PrecisionM
5、ass StandardsE898 Test Method of Testing Top-Loading, Direct-ReadingLaboratory Scales and Balances2.2 ISO Documents:2ISO 3534 StatisticsVocabulary and SymbolsISO 653 Long Solid-Stem Thermometers for Precision UseISO 655 Long Enclosed-Scale Thermometers for PrecisionUseISO 4787 Laboratory GlasswareVo
6、lumetric GlasswareMethods for Testing and Use2.3 Other Documents3OIML R 111-1 Weights of classes E1,E2,F1,F2,M1,M12,M2,M23and M3: Part 1: Metrological and technicalrequirements3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 accuracy4the accuracy of an instrument is theclosenes
7、s of agreement between the nominal volume and themean volume, obtained by applying the test procedure speci-fied in Section 13 of this specification. It is quantified by theinaccuracy of the mean.3.1.2 dead volumethe dead volume is that part of the totalliquid volume, held in the operational part of
8、 the device, whichis not delivered.3.1.2.1 DiscussionThe dead volume should not be con-fused with the dead space of an air displacement instrument.3.1.3 disposablethose parts of an instrument that areintended to be used once only and then discarded. Disposableparts are generally intended for use in
9、applications wheresample carryover is intolerable.3.1.4 maximum errorthe maximum difference betweenthe nominal volume and any single individual volume obtainedby applying the test procedure specified in Section 13 of thisSpecification.3.1.5 maximum expectable errorwith more than 95 %probability, the
10、 maximum expectable error is calculated asfollows:61ET112s! (1)where:ET= inaccuracy of the mean, ands = standard deviation from the repeatability test in Section13.3.1.6 nominal volume(s)the stated volume(s) for whichperformance is specified.3.1.7 piston or plunger operated volumetric apparatus(POVA
11、)the volume of liquid to be measured with POVA isdefined by one or more strokes of one or more pistons orplungers. POVA may be operated manually or mechanically(for example, electrically, pneumatically or by hydrostaticpressure).3.1.7.1 DiscussionIn the following text the word pistonmeans piston or
12、plunger.1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Subcommittee E41.06 onWeighing Devices.Current edition approved Dec. 1, 2014. Published January 2015. Originallyapproved in 1987. Last previous edition approved in 2
13、008 as E1154-89 (2008). DOI:10.1520/E1154-14.2Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.3Available from International Organization of Legal Metrology, 11 rue Turgot,75009 Paris, France. www.oilm.org/en/4These definit
14、ions apply only in the cases where the distributions are Gaussian.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.8 precision4the closeness of agreement between theindividual volumes obtained by applying the test procedurespecifie
15、d in this specification. It is quantified by the impreci-sion.3.1.8.1 DiscussionThe test procedure specified gives onlya measure of the repeatability (see ISO 3534) under controlledconditions.3.1.9 reference temperaturethe temperature at which theinstrument is designed to deliver its nominal volume(
16、s).3.1.9.1 DiscussionAt that temperature the closest agree-ment between manufacturers performance claims and testresults may be expected.3.1.10 reference temperature rangethat temperature rangefor which the tolerances for accuracy are specified.3.1.11 reusablethose parts of an instrument that are me
17、antto be used more than once.As the reusability of some parts canrarely be quantified, any institution or individual who reuses areusable part must see to its safety and effectiveness. Reusableparts are generally intended for use in applications wheresample carryover is tolerable, or can be adequate
18、ly prevented.3.1.12 sample carryoverthat portion of the sample that isretained in the instrument and that may affect subsequentsamples.3.1.13 stated featureany feature claimed by the manufac-turer.3.1.14 unit of volumethe millilitre or the microlitre, thatare accepted substitutes for the cubic centi
19、metre or cubicmillimetre.3.1.14.1 DiscussionIt is recommended that volumesshould be specified in microlitres up to 999 L, and inmillilitres from 1 mL.3.1.15 working rangethat part (of the total range) forwhich manufacturers performance specifications are given.3.1.16 working temperature rangethat ra
20、nge of tempera-tures for which manufacturers performance specifications aregiven.4. Classification4.1 Types of POVAPiston or plunger operated volumetricapparatus (POVA) are classified as follows:4.1.1 PipetteA measuring instrument for the transfer of apredetermined volume of liquid from one vessel t
21、o another. Itis not connected to a reservoir.4.1.2 DispenserA measuring instrument for deliveringpredetermined volumes of liquid from a reservoir. The reser-voir may be integrated with the instrument or connectedexternally.4.1.3 DilutorA measuring instrument for taking up differ-ent liquids (for exa
22、mple, sample and diluent) and deliveringthem in combination so as to comprise a predetermined ratio,or predetermined volumes, or both. The reservoir of diluentmay be integrated with the instrument or connected externally.4.1.4 Displacement BuretA measuring instrument fromwhich the volume delivered i
23、s determined by an externalindicator. The volume delivered can then be read.4.2 Types of Displacement:4.2.1 Displacement with an air interface (“air displace-ment”). The delivered liquid is displaced by an air interface(indirect action), (see Figs. 1 and 2).4.2.2 Displacement without an air interfac
24、e (“positive dis-placement”). The delivered liquid is displaced either by aliquid interface (indirect action) or by actual contact with thepiston (direct action), (see Fig. 3 and Fig. 4).5. Performance Requirements5.1 Performance Tolerances:5.1.1 Performance tolerances specified for POVA are meantto
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME11542014STANDARDSPECIFICATIONFORPISTONORPLUNGEROPERATEDVOLUMETRICAPPARATUS 活塞 柱塞 操作 容量 测量 装置 标准

链接地址:http://www.mydoc123.com/p-528028.html