1、Designation: E 1085 95 (Reapproved 2004)1Standard Test Method forX-Ray Emission Spectrometric Analysis of Low-AlloySteels1This standard is issued under the fixed designation E 1085; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEReference to the Research Report in Section 16 and the footnote were editorially removed in January 2009.1. Scope1
3、.1 This test method covers the wavelength dispersiveX-ray spectrometric analysis of low-alloy steels for the follow-ing elements:Element Concentration Range, %Nickel 0.04 to 3.0Chromium 0.04 to 2.5Manganese 0.04 to 2.5Silicon 0.06 to 1.5Molybdenum 0.005 to 1.5Copper 0.03 to 0.6Vanadium 0.012 to 0.6C
4、obalt 0.03 to 0.2Sulfur 0.009 to 0.1Niobium 0.002 to 0.1Phosphorus 0.010 to 0.08Calcium 0.001 to 0.0071.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and he
5、alth practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in Section 10.2. Referenced Documents2.1 ASTM Standards:2E 135 Terminology Relating to Analytical Chemistry forMetals, Ores, and Related MaterialsE 305 Practice for Es
6、tablishing and Controlling AtomicEmission Spectrochemical Analytical CurvesE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 1361 Guide for Correction of Interelement Effects inX-Ray Spectrometric AnalysisE 1622 Practice for Correction of Spectral Lin
7、e Overlap inWavelength-Dispersive X-Ray Spectrometry33. Terminology3.1 For definitions of terms used in this test method, refer toTerminology E 135.4. Summary of Test Method4.1 The test specimen is finished to a clean uniform surfaceand then irradiated with an X-ray beam of high energy. Thesecondary
8、 X rays produced are dispersed by means of crystals,and the intensities are measured by suitable detectors atselected wavelengths. Radiation measurements are made basedon the time required to reach a fixed number of counts, or onthe total counts obtained for a fixed time. Concentrations of theelemen
9、ts are determined by relating the measured radiation ofunknown specimens to analytical curves prepared with suitablereference materials. Either a fixed-channel, polychromatorsystem or a sequential, monochromator system may be used toprovide simultaneous or sequential determinations of elements.5. Si
10、gnificance and Use5.1 This procedure is suitable for manufacturing control andfor verifying that the product meets specifications. This testmethod provides rapid, multielement determinations with suf-ficient accuracy to ensure product quality and minimize pro-duction delays. The analytical performan
11、ce data may be usedas a benchmark to determine if similar X-ray spectrometersprovide equivalent precision and accuracy, or if the perfor-mance of a particular X-ray spectrometer has changed.5.2 Calcium is sometimes added to steel to effect inclusionshape control in order to enhance certain mechanica
12、l propertiesof steel. This test method is useful for determining the residualcalcium in the steel after such treatment.5.2.1 Because calcium occurs primarily in inclusions, theprecision of this test method is a function of the distribution ofthe calcium-bearing inclusions in the steel. The variation
13、 ofdeterminations on freshly prepared surfaces will give someindication of the distribution of these inclusions.1This test method is under the jurisdiction of ASTM Committee E01 onAnalytical Chemistry for Metals, Ores, and Related Materials and is the directresponsibility of Subcommittee E01.01 on I
14、ron, Steel, and Ferroalloys.Current edition approved Oct. 1, 2004. Published November 2004. Originallyapproved in 1987. Last previous edition approved in 2000 as E 1085 95 (2000).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org.
15、 For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, P
16、A 19428-2959, United States.6. Interferences6.1 Interelement or matrix effects may exist for some of theelements in 1.1. Mathematical corrections may be used to solvefor these effects. Various mathematical correction proceduresare commonly utilized. See Guide E 1361 and Practice E 1622.Any of these
17、procedures is acceptable that will achieveanalytical accuracy equivalent to that provided by this testmethod.6.2 Because trace amounts of calcium are being determinedwith this test method, exercise care not to contaminate thespecimen. The presence of calcium in the grinding mediumwill contaminate th
18、e specimen to the extent that erratic andincorrect results will be obtained. Therefore, the grindingmedium shall be analyzed for calcium and only those materialsthat are free of calcium shall be used.7. Apparatus7.1 Specimen Preparation Equipment:7.1.1 Surface Grinder or Sander With Abrasive Belts,
19、Disks,or Lathe, capable of providing a flat, uniform surface on thereference materials and test specimens.7.1.1.1 When calcium is to be determined, 240-grit,calcium-free silicon carbide belts or disks shall be used.7.2 Excitation Source:7.2.1 X-Ray Tube Power Supply, providing a constant po-tential
20、or rectified power of sufficient energy to producesecondary radiation of the specimen for the elements specified.The generator may be equipped with a line voltage regulatorand current stabilizer.7.2.2 X-Ray Tubes, with targets of various high-purityelements, that are capable of continuous operation
21、at requiredpotentials and currents, and will excite the elements to bedetermined.7.2.2.1 For the determination of calcium only chromiumtarget tubes were tested. Other targets shall be tested prior touse.7.3 Spectrometer, designed for X-ray emission analysis, andequipped with specimen holders and a s
22、pecimen chamber. Thechamber may contain a specimen spinner, and must beequipped for vacuum or helium-flushed operation for thedetermination of elements of Atomic Number 20 (calcium) orlower.7.3.1 Analyzing Crystals, flat or curved crystals with opti-mized capability for the diffraction of the wavele
23、ngths ofinterest.7.3.2 Collimator, for limiting the characteristic X rays to aparallel bundle when flat crystals are used in the instrument.For curved crystal optics, a collimator is not necessary.7.3.3 Detectors, sealed or gas-flow proportional-type, scin-tillation counters, or equivalent.7.3.4 Vac
24、uum System, providing for the determination ofelements whose radiation is absorbed by air (for example,calcium, silicon, phosphorus, and sulfur). The system shallconsist of a vacuum pump, gage, and electrical controls toprovide automatic pumpdown of the optical path and maintaina controlled pressure
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME108519952004E1431STANDARDTESTMETHODFORXRAYEMISSIONSPECTROMETRICANALYSISOFLOWALLOYSTEELSPDF

链接地址:http://www.mydoc123.com/p-527879.html