ASTM E1083-2000(2006) Standard Test Method for Sensory Evaluation of Red Pepper Heat《红辣椒热量的感官评定标准试验方法》.pdf
《ASTM E1083-2000(2006) Standard Test Method for Sensory Evaluation of Red Pepper Heat《红辣椒热量的感官评定标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1083-2000(2006) Standard Test Method for Sensory Evaluation of Red Pepper Heat《红辣椒热量的感官评定标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1083 00 (Reapproved 2006)Standard Test Method forSensory Evaluation of Red Pepper Heat1This standard is issued under the fixed designation E 1083; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes standardized procedures forthe sensory evaluation of heat in ground red pepper2rangingfrom 10 000 t
3、o 70 000 scoville heat units.1.2 This test method is intended as an alternative to theScoville Heat Test, but results can be expressed in scoville heatunits (SHU).1.3 This test method does not apply for oleoresin capsi-cums, low-heat chili peppers, or chili powder.1.4 This standard does not purport
4、to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardsstatements are given in Section 8
5、.2. Referenced Documents2.1 ASTM Publication:3STP 434 Manual on Sensory Testing Methods2.2 ISO Standard:43513-1977(E) Spices and CondimentsChilliesDetermination of Scoville Index3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 approaching strong heatN-vanillyl-n-nonamide,1.30 p
6、pm. This is 13.0 cm on the 15-cm line scale. It is unusualto see a ground red pepper stronger than this. But in the eventthat a pepper with more than 70 000 SHU is tested, thereremains the last 2 cm on the line scale.3.1.2 moderate heatN-vanillyl-n-nonamide, 0.80 ppm.This is a “moderate” amount of p
7、epper heat. On the line scale,10 cm.3.1.3 rinseto purge the oral cavity with unsalted sodacrackers and water by slowly chewing and swallowing thecracker, followed by swirling the water around in the mouthand swallowing. This procedure is repeated as often as isnatural and comfortable for the panelis
8、t.3.1.4 scoville heat units (SHU)the commonly acceptedunit for expressing heat levels in capsicum products (see 2.1and 2.2). Scoville heat units range from 0 to 1 500 000.3.1.5 slight heatN-vanillyl-n-nonamide, 0.40 ppm. This isa “slight” amount of pepper heat. On the line scale, 5 cm.3.1.6 stock so
9、lutiona standardized solution of 6.0 ppm ofN-vanillyl-n-nonamide that is used to prepare other dilutions ofN-vanillyl-n-nonamide (see 10.1.2).3.1.7 strong heatbest defined by concept. Hotter than the1.30 ppm N-vanillyl-n-nonamide sample. On the line scale, 15cm.3.1.8 threshold heatbest defined by co
10、ncept rather than bya standard dilution of N-vanillyl-n-nonamide. Threshold is thatpoint where a panelist just barely senses burn/heat. On the linescale, 1.25 cm.3.1.9 zero heatN-vanillyl-n-nonamide, 0 ppm. No sen-sory heat. On the line scale, 0 cm.4. Summary of Test Method4.1 Ground red pepper is s
11、teeped in hot water withpolysorbate-80 for 20 min, filtered, and the filtrate diluted inroom temperature water. Trained panelists compare the heat inthe pepper extract to a known concentration of a standardsolution of synthetic capsaicin (N-vanillyl-n-nonamide) using a15-cm line scale. The tasting p
12、rocedure is timed and takes 2min for one test sample and 9 min for 2 test samples.54.2 Panelists are screened for their accuracy and precisionand trained to use the 15-cm line scale during two to three15-min training sessions.1This test method is under the jurisdiction ofASTM Committee E18 on Sensor
13、yEvaluation and is the direct responsibility of Subcommittee E18.06 on Food andBeverage Evaluation.Current edition approved April 1, 2006. Published April 2006. Originallyapproved in 1986. Last previous edition approved in 2000 as E 1083 00e1.2Available from the American Spice Trade Association, 580
14、 Sylvan Ave.,Englewood Cliffs, NJ 07632.3Available from ASTM International Headquarters, 100 Barr Harbor Drive, POBox C700, West Conshohocken, PA 194282959.4Available from International Organization for Standardization (ISO), 1 rue deVaremb, Case postale 56, CH-1211, Geneva 20, Switzerland.5Gillette
15、, M. H., Appel, C. E., Lego, M. “A New Method for the SensoryEvaluation of Red Pepper Heat,” Journal of Food Science, Vol. 49, No. 4, 1984, p1028.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.3 Standard general requirements for s
16、ensory testing arefollowed in accordance with ASTM STP 434.5. Significance and Use5.1 This test provides quick and accurate ratings for thesensory heat in ground red peppers ranging from 10 000 to70 000 scoville heat units.5.2 Sensory results from this test method correlate highly(r = 0.94) with res
17、ults from high pressure liquid chromatogra-phy; making the two methods substitutable.66. Apparatus6.1 Two Magnetic Hot Plate Stirrers.6.2 Four beakers, 400 mL.6.3 One Small Beaker, (50 to 100 mL).6.4 One Analytical Balance (sensitive to 0.00 g).6.5 Two Volumetric Flasks, stoppered, 1000 mL.6.6 One S
18、topwatch.7. Reagents and Materials7.1 Coffee-Type or Low Flavor Qualitative Filter Paper.7.2 Medicine Cups.7.3 Unsalted Soda Crackers.7.4 Bottled Distilled or Deionized Water when available, orstill spring water.7.5 Polysorbate-80 (Food Grade).7.6 Rating Forms (15-cm line scale anchored at 0 (none),
19、1.25 cm (threshold), 5 cm (slight), 10 cm (moderate), 15 cm(strong); see Appendix X1.7.7 N-vanillyl-n-nonamide, available from Penta Interna-tional.8. Hazards8.1 Pure N-vanillyl-n-nonamide will burn the eyes and skinupon direct contact. Gloves and caution must be used whenhandling N-vanillyl-n-nonam
20、ide in the crystalline form.9. Calibration and Standardization of Panelists9.1 Select, at random, 10 to 12 panelists. Selection shouldbe based upon availability, attitude, and motivation of panel-ists. Screening for taste sensitivity is not necessary.9.2 Prepare stock solution of N-vanillyl-n-nonami
21、de (see10.1.2).9.3 Dilute the stock solution of N-vanillyl-n-nonamide tothe following concentrations:9.3.1 N-vanillyl-n-nonamide (0 ppm)Add none of thestock solution to 200 mL of water.9.3.2 N-vanillyl-n-nonamide (0.40 ppm)Dilute 13.4 g ofstock solution to 200 mL with water.9.3.3 N-vanillyl-n-nonami
22、de (0.80 ppm)Dilute 26.8 g ofthe stock solution to 200 mL with water.9.3.4 N-vanillyl-n-nonamide (1.30 ppm)Dilute 43.3 g ofthe stock solution to 200 mL with water.9.4 Session I (15 min)Brief the randomly selected panel-ists on the purpose of this test method. The purpose of the firstsession is to st
23、andardize their tongues and mouth to thereference standards with respect to the 15-cm line scale on theballot (Appendix X1). Explain to the panelists that they mayuse any of the infinite number of points on the line scale todescribe how hot a given sample is. Panelists will taste (see10.2.3.1-10.2.3
24、.3) the coded standard dilutions you prepared,evaluate them critically, concentrating and memorizing theirindividual sensory heat levels. Panelists rinse well betweensamples with crackers and water for 2 min (they are timed).After the standards have been tasted, the correct rating for eachreference
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME108320002006STANDARDTESTMETHODFORSENSORYEVALUATIONOFREDPEPPERHEAT 红辣椒 热量 感官 评定 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-527872.html