ASTM E1079-2010 5000 Standard Practice for Calibration of Transmission Densitometers《透射密度计校准的标准规程》.pdf
《ASTM E1079-2010 5000 Standard Practice for Calibration of Transmission Densitometers《透射密度计校准的标准规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1079-2010 5000 Standard Practice for Calibration of Transmission Densitometers《透射密度计校准的标准规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1079 10Standard Practice forCalibration of Transmission Densitometers1This standard is issued under the fixed designation E1079; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in p
2、arentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice2covers the calibration of transmissiondensitometers used to perform radiographic film density mea-surements (see Note 1).1.2 This st
3、andard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1For further informat
4、ion on the design and use of densitom-eters, the following literature is suggested as additional backgroundinformation: ISO 51:2009, ISO 52:2009, and ISO 14807:2001.2. Referenced Documents2.1 ASTM Standards:3E1316 Terminology for Nondestructive Examinations2.2 ISO Standards:4ISO 51:2009 Photography
5、and graphic technology - Den-sity measurements - Part 1: Geometry and functionalnotationISO 52:2009 Photography and graphic technology - Den-sity measurements - Part 2: Geometric conditions fortransmittance densityISO 14807:2001 Photography - Transmission and reflectiondensitometers - Method for det
6、ermining performance3. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, see Terminology E1316.4. Significance and Use4.1 This practice provides a means for calibrating transmis-sion densitometers used for the measurement of radiographicfilm density. A transmission densitome
7、ter calibrated in accor-dance with this practice provides the assurance that accuratedensity values of radiographs are obtained.5. Apparatus5.1 Apparatus should consist of the following:5.1.1 A calibrated step tablet shall be used. The step tabletmay be a NIST X-ray Step Tablet (X-Ray Film Step Tabl
8、etTransmission Density Standard 38100C)5or alternately a steptablet from another supplier, which is traceable to the NISTstep tablet. The step tablet shall have at least five step densities,which cover the density range that is used for productionradiographs. A calibration certificate shall be provi
9、ded with thestep tablet indicating the tablet ID and recorded values for eachstep density. For suppliers of step tablets other than NIST, thecertificate shall indicate conformance of traceability to NISTinstrumentation used in the calibration process, applicableANSI standards used, verification of m
10、easurement on a NISTstep tablet, the ID number of the step tablet, and calibrationdate of the step tablet. Precautions should be taken in thestorage, handling, and use of the step tablet. In the event itbecomes scratched, blemished, or exhibits other signs ofdeleterious wear, it should be replaced i
11、mmediately. The NIST(or alternate, if used) step tablet shall be replaced four yearsfrom the date of first use.61This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.01 onRadiology (X and Gamma) Method.Current e
12、dition approved June 1, 2010. Published July 2010. Originally approvedin 1985. Last previous edition approved in 2005 as E1079 - 05. DOI: 10.1520/E1079-10.2For ASME Boiler and Pressure Vessel Code applications see related PracticeSE-1079 in Section II of that Code.3For referenced ASTM standards, vis
13、it the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York
14、, NY 10036.5Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.6Expiration interval of the NIST or alternate step tablet may be different than therequirements of this practice. Unless otherwise specified, re
15、quirements of thispractice shall apply.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.2 Transmission Densitometers, with either direct-scalereadout or digital readout displays specifically manufacturedfor the purpose of measurin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME107920105000STANDARDPRACTICEFORCALIBRATIONOFTRANSMISSIONDENSITOMETERS 透射 密度计 校准 标准 规程 PDF

链接地址:http://www.mydoc123.com/p-527866.html