1、Designation: E 1003 05Standard Test Method forHydrostatic Leak Testing1This standard is issued under the fixed designation E 1003; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses i
2、ndicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the testing of components forleaks by pressurizing them inside with a liquid.1.2 This test method can be used on piping, valves, andc
3、ontainers with welded or fitted sections which can be sealed attheir ends and which are designed for internal pressure.1.3 Basic procedures are described based on the type ofinspection used. These procedures should be limited to findingleakage indications of 4.5 3 109mol/s (1 3 104Std cm3/s)2or larg
4、er.1.4 The values stated in SI units are to be regarded asstandard.1.5 This standard does not purport to address the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicabili
5、ty of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E 543 Practice for Agencies Performing NondestructiveTestingE 1316 Terminology for Nondestructive Testing2.2 ASNT Documents:4SNT-TC-1A Recommended Practice for Personal Qualifica-tion and Certification in Nondestruct
6、ive TestingANSI/ASNT CP-189 ASNT Standard for Qualification andCertification of Nondestructive Testing Personnel42.3 AIA Standard:5NAS-410 Certification and Qualification of NondestructiveTest Personnel3. Terminology3.1 DefinitionsFor definitions of terms used in this stan-dard, see Terminology E 13
7、16 Section E.4. Summary of Test Method4.1 Hydrostatic testing requires that a component be com-pletely filled with a liquid, such as water. Pressure is slowlyapplied to the liquid until the required pressure is reached. Thispressure is held for the required time at which point thecomponent is inspec
8、ted visually to locate leaks or the pressureon the gauge is recorded to determine the components totalleakage.4.2 The two basic procedures are described together withmethods for improving their sensitivity.4.2.1 Pressure Drop IndicationThis procedure is usedprimarily to measure total system leakage.
9、4.2.2 Visual Inspection for Leakage This procedure isintended primarily to locate leaks.4.3 Ultrasonic pretesting for gross leaks is described.5. Basis of Application5.1 The following items are subject to contractual agree-ment between the parties using or referencing this test method:5.2 Personnel
10、Qualification5.2.1 If specified in the contractual agreement. Personnelperforming examinations to this test method shall be qualifiedin accordance with a nationally or internationally recognizedNDT personnel qualification practice or standard such asANSI/ASNT CP-189, SNT-TC-1A, NAS-410, or similar d
11、ocu-ment and certified by the employer or certifying agency, asapplicable. The practice or standard used and its applicablerevision shall be identified in the contractual agreement.5.3 Qualification of Nondestructive AgenciesIf specifiedin the contractual agreement, NDT agencies shall be qualifiedan
12、d evaluated as described in Practice E 543. The applicableedition of Practice E 543 shall be specified in the contractualagreement.1This test method is under the jurisdiction of ASTM Committee E07 onNondestructive Testing and is the direct responsibility of Subcommittee E07.08 onLeak Testing.Current
13、 edition approved Dec. 1, 2005. Published December 2005. Originallyapproved in 1984. Last previous edition approved in 2000 as E 1003 - 95(2000).2The gas temperature is referenced to 0C. To convert to another gas referencetemperature, Tref, multiply the leak rate by (Tref+ 273)/273.3For referenced A
14、STM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from American Society for Nondestructive Testing, 1711 ArlingatePla
15、za, P.O. Box 28518, Columbus, OH 43228-0518.5Available from Aerospace Industries Association of America, Inc. (AIA), 1250Eye St., NW, Washington, DC 20005.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.4 Re-examination of Repaired
16、/Reworked ItemsRe-examination of repaired/reworked items is not addressed in thistest method, they shall be specified in the contractual agree-ment.6. Significance and Use6.1 This test method is useful for quality control testing andfield inspection of piping systems, pipelines, valves, andcontainer
17、s that are expected to retain liquids. It is not sensitiveenough for leak testing when toxic or explosive gas is expectedto be retained under pressure.7. Interferences7.1 The interior and exterior welds and joints where leaksare often found must be free of oil, grease, flux, slag, or othercontaminan
18、ts that might temporarily block or mask leakage.New systems should be tested prior to painting, where practi-cal.7.2 Hydrostatic testing should not be performed before aleak test using air or a tracer gas. The liquid test media mayclog small leaks causing later tests to be inaccurate.7.3 Test liquid
19、 must be equal or above atmosphere tempera-ture or droplets will form on the outside. The minimumtemperature of the liquid should be 16C 61F.7.4 If the container to be tested has parts made of stainlesssteel, nickel, or chromium alloys, the liquid or any additivesused must have a sulfur and halogen
20、content of less than 50ppm of each. If water is used as a test fluid it should bedeionized.7.5 To avoid brittle fracture, the test pressure must not beapplied until the metal and the test fluid are approximately thesame temperature. The metal should be a minimum of 16C61F prior to the application of
21、 pressure.7.6 If a test liquid other than water is used, the liquids flashpoint should be 93C 200F or above.7.7 If plastic parts are used in the test container, the fluidshould not promote stress cracking or softening on the plastic.7.8 When the test container has carbon steel components, arust inhi
22、bitor should be used.8. Apparatus8.1 Pressure GaugeThe gauge must be able to withstandnormal test pressures and be accurate enough to record smallpressure drops. Pressure gauges should be calibrated beforeeach test. The gauge must be accurate to within 1 % of fullscale. The gauge must read at least
23、1.5 3 but not more than4 3 the maximum test pressure to be used. (See TerminologyE 1316 for a description of terms.)8.2 Pressure Relief Valve.8.3 Pressure Alarm.8.4 Emergency Pressure Shut-Off Valve.8.5 Trapped Air Vent.8.6 Pressure Pump.8.7 Liquid Test Media.8.8 Pressure Hoses and Fittings.8.9 Prot
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME10032005STANDARDTESTMETHODFORHYDROSTATICLEAKTESTING 静水 泄漏 试验 标准 方法 PDF

链接地址:http://www.mydoc123.com/p-527709.html