《ASTM E1001-2016 9115 Standard Practice for Detection and Evaluation of Discontinuities by the Immersed Pulse-Echo Ultrasonic Method Using Longitudinal Waves《用纵波浸入脉冲回波超声法检测并评估间断性的标准.pdf》由会员分享,可在线阅读,更多相关《ASTM E1001-2016 9115 Standard Practice for Detection and Evaluation of Discontinuities by the Immersed Pulse-Echo Ultrasonic Method Using Longitudinal Waves《用纵波浸入脉冲回波超声法检测并评估间断性的标准.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1001 16Standard Practice forDetection and Evaluation of Discontinuities by theImmersed Pulse-Echo Ultrasonic Method Using LongitudinalWaves1This standard is issued under the fixed designation E1001; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1.
3、 Scope*1.1 This practice describes procedures for the ultrasonicexamination of bulk materials or parts by transmitting pulsed,longitudinal waves through a liquid couplant into the materialand observing the indications of reflected waves (see Fig. 1). Itcovers only examinations in which one search un
4、it is used asboth transmitter and receiver (pulse-echo) and in which the partor material being examined is coupled to the part by a liquidcolumn or is totally submerged in the couplant (either methodis considered to be immersion testing). This practice includesgeneral requirements and procedures whi
5、ch may be used fordetecting discontinuities and for making a relative or approxi-mate evaluation of the size of discontinuities.1.2 This practice replaces Practice E214 and provides moredetailed procedures for the selection, standardization, andoperation of an examination system and for evaluation o
6、f theindications obtained.1.3 UnitsThe values stated in inch-pound units are to beregarded as standard. The values given in parentheses aremathematical conversions to SI units that are provided forinformation only and are not considered standard.1.4 This standard does not purport to address all of t
7、hesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C1212 Practice for Fabrica
8、ting Ceramic Reference Speci-mens Containing Seeded VoidsC1336 Practice for Fabricating Non-Oxide Ceramic Refer-ence Specimens Containing Seeded InclusionsE127 Practice for Fabrication and Control of AluminumAlloy Ultrasonic Standard Reference BlocksE317 Practice for Evaluating Performance Character
9、istics ofUltrasonic Pulse-Echo Testing Instruments and Systemswithout the Use of Electronic Measurement InstrumentsE428 Practice for Fabrication and Control of Metal, Otherthan Aluminum, Reference Blocks Used in UltrasonicTestingE543 Specification for Agencies Performing NondestructiveTestingE1158 G
10、uide for Material Selection and Fabrication ofReference Blocks for the Pulsed Longitudinal Wave Ul-trasonic Testing of Metal and Metal Alloy ProductionMaterialE1316 Terminology for Nondestructive Examinations2.2 ASNT Documents:3SNT-TC-1A Recommended Practice for Personnel Qualifi-cation and Certific
11、ation in Nondestructive TestingANSI/ASNT-CP-189 for Qualification and Certification ofNondestructive Testing Personnel2.3 Aerospace Industries Association Document:4NAS-410 Certification and Qualification of NondestructiveTesting PersonnelNOTE 1For DoD contracts, unless otherwise specified the issue
12、s of thedocuments, which are DoD adopted, are those listed in the issue of theDoDISS (Department of Defense Index of Specifications Standards) citedin the solicitation.1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcom
13、mittee E07.06 onUltrasonic Method.Current edition approved Dec. 1, 2016. Published December 2016. Originallyapproved in 1984. Last previous edition approved in 2011 as E1001 - 11. DOI:10.1520/E1001-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Servi
14、ce at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available fromAmerican Society for Nondestructive Testing (ASNT), P.O. Box28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http:/www.asnt.org.4Available fro
15、m Aerospace Industries Association of America, Inc. (AIA), 1000Wilson Blvd., Suite 1700,Arlington, VA22209-3928, http:/www.aia-aerospace.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-
16、2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organiziation Technic
17、al Barriers to Trade (TBT) Committee.12.4 ISO Documents5ISO 9712 Non-destructive TestingQualification and Cer-tification for NDT Personnel3. Terminology3.1 DefinitionsFor definitions of terms used in thispractice, see Terminology E1316.3.2 Definitions of Terms Specific to This Standard:3.2.1 effecti
18、ve beam diameterthat distance through whicha search unit can be traversed across a reference reflector sothat the corresponding echo amplitude is at least one half (-6dB) of the maximum amplitude. The effective beam diameter isnot a characteristic of the search unit alone, but is dependent onpropaga
19、ting medium, distance to the discontinuity, reflectorgeometry, etc.3.2.2 scan indexthe length of the step created by indexingthe scan of the search unit over the part, that is continuouslyscanning in one direction, then stepping in the directionperpendicular to the scan or making a linear advance pe
20、rrotation (pitch) for rotary scan of cylindrical parts. Theallowable scan index should be correlated with the search uniteffective beam diameter to ensure full coverage of the part asdescribed in 8.2 below.3.2.3 transfera change in scanning gain to compensate fordifferences in attenuation of the ref
21、erence standard and the partor material being examined.4. Summary of Practice4.1 This practice describes a means for obtaining an evalu-ation of discontinuities in materials by immersed examinationwith longitudinal ultrasonic waves. Equipment, referencestandards, examination and evaluation procedure
22、s, and docu-mentation are described in detail.5. Basis of Application5.1 The following items are subject to contractual agree-ment between the parties using or referencing this standard.5.2 Personnel Qualification:5.2.1 If specified in the contractual agreement, personnelperforming examinations to t
23、his standard shall be qualified inaccordance with a nationally or internationally recognizedNDT personnel qualification practice or standard such asANSI/ASNT-CP-189, SNT-TC-1A, NAS-410, ISO 9712, or asimilar document and certified by the employer or certifyingagency, as applicable. The practice or s
24、tandard used and itsapplicable revision shall be identified in the contractual agree-ment between the using parties.5.3 Qualification of Nondestructive AgenciesIf specifiedin the contractual agreement, NDT agencies shall be qualifiedand evaluated as described in Specification E543. The appli-cable e
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME100120169115STANDARDPRACTICEFORDETECTIONANDEVALUATIONOFDISCONTINUITIESBYTHEIMMERSEDPULSEECHOULTRASONICMETHODUSINGLONGITUDINALWAVES

链接地址:http://www.mydoc123.com/p-527705.html