ASTM D7742-2011 8750 Standard Practice for Determination of Nonylphenol Polyethoxylates (NPnEO, 3 n 18) and Octylphenol Polyethoxylates (OPnEO, 2 n 2).pdf
《ASTM D7742-2011 8750 Standard Practice for Determination of Nonylphenol Polyethoxylates (NPnEO, 3 n 18) and Octylphenol Polyethoxylates (OPnEO, 2 n 2).pdf》由会员分享,可在线阅读,更多相关《ASTM D7742-2011 8750 Standard Practice for Determination of Nonylphenol Polyethoxylates (NPnEO, 3 n 18) and Octylphenol Polyethoxylates (OPnEO, 2 n 2).pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7742 11Standard Practice forDetermination of Nonylphenol Polyethoxylates (NPnEO, 3 #n # 18) and Octylphenol Polyethoxylates (OPnEO, 2 # n #12) in Water by Single Reaction Monitoring (SRM) LiquidChromatography/ Tandem Mass Spectrometry (LC/MS/MS)1This standard is issued under the fixed
2、designation D7742; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revis
3、ion or reapproval.1. Scope1.1 This procedure covers the determination of nonylphenolpolyethoxylates (NPnEO, 3 # n # 18) and octylphenolpolyethoxylates (OPnEO, 2 # n # 12) in water by SingleReaction Monitoring (SRM) Liquid Chromatography/ TandemMass Spectrometry (LC/MS/MS) using direct injection liqu
4、idchromatography (LC) and detected with tandem mass spec-trometry (MS/MS) detection. This is a screening Practice withqualified quantitative data to check for the presence of longerchain ethoxylates in a water sample.1.1.1 All data are qualified because neat standards of eachalkylphenol ethoxylate (
5、APEO) are not available and thesynthesis and characterization of these neat standards would bevery expensive. The Igepalt Brand standards, which contain amixture of various chain lengths of the alkylphenol ethoxylates(APEOs), were used. The mixture was characterized in-houseassuming the instrument r
6、esponse at an optimum electrosprayionization cone and collision voltage for each APEO was thesame. This assumption, which may not be accurate, is used todetermine qualified amounts of each ethoxylate in the stan-dards. The n-Nonylphenol diethoxylate (n- NP2EO) surrogatewas available as a neat charac
7、terized standard, therefore, thisconcentration and recovery data was not estimated. APEOs arenot regulated by the EPA, but nonylphenol, a breakdownproduct of NPnEOs, is regulated for fresh and saltwaterdischargers. A request by a sewage treatment plant (STP) wasmade to make this Practice available t
8、hroughASTM in order toscreen for the influent or effluent from sources of APEOscoming into the STP. The interest lies in stopping the source ofthe longer chainAPEOs from entering the STP in order to meeteffluent guidelines. Based upon the above, this is a Practicerather than a Standard Method.Acompa
9、rison between samplesis possible using this Practice to determine which has a higherconcentration of APEOs.1.2 UnitsThe values stated in SI units are to be regardedas standard. No other units of measurement are included in thisstandard.1.3 The estimated screening range shown in Table 1 wascalculated
10、 from the concentration of the Level 1 and 7calibration standards shown in Table 4. These numbers arequalified, as explained in Section 1, and must be reported assuch. Figs. 1-5 show the SRM chromatograms of each analyteat the Level 1 concentration with the signal to noise (S/N) ratio.This is a scre
11、ening Practice and method detection limits are notgiven. The S/N ratio for each analyte at the Level 1 concen-tration must be at least 5:1 for adequate sensitivity. If theinstrument can not meet the criteria, the screening limit mustbe raised to an acceptable level.1.4 This standard does not purport
12、 to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193
13、Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3856 Guide for Good Laboratory Practices in Laborato-ries Engaged in Sampling and Analysis of WaterD3694 Practices for Preparation of Sample Containers andfor Pre
14、servation of Organic ConstituentsD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisE2554 Practice for Estimating and Monitoring the Uncer-tainty of Test Results of a Test Method in a SingleLaboratory Using a Control Sample Program1This Practice is u
15、nder the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee D19.06 on Methods for Analysis forOrganic Substances in Water.Current edition approved June 15, 2011. Published July 2011.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orconta
16、ct ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2.2 Other Standard:3EPA
17、 SW-846 Test Methods for Evaluating Solid Waste,Physical/Chemical Methods3. Terminology3.1 Definitions:3.1.1 Screening Limit, SL, nthe estimated concentrationof the lowest-level calibration standard used for quantificationaccounting for the sample dilution.3.1.2 Alkylphenol Ethoxylates, nin this Pra
18、ctice, nonyl-phenol polyethoxylates (NPnEO, 3#n#18) and octylphenolpolyethoxylates (OPnEO, 2 # n # 12) collectively.3.2 Abbreviations:3.2.1 ppt parts per trillion, ng/L3.2.2 mM millimolar,1x10-3moles/L3.2.3 ND non-detect4. Summary of Practice4.1 This is a performance based Practice and modifications
19、are allowed to improve performance.4.2 For APEOs analysis, samples are shipped to the labbetween 0C and 6C containing 1% formaldehyde and ana-lyzed within 7 days of collection. In the lab, an aliquot of thesample is filtered, spiked with surrogate, and analyzed directlyby LC/MS/MS.4.2.1 Field sample
20、s from sewage systems propose a chal-lenging analysis. Since this is a screening technique to deter-mine if APEOs are present, a 10-25 mL aliquot of the sampleis filtered through a PVDF syringe driven filter unit beforespiking with surrogate. It was demonstrated that similar recov-eries of the APEOs
21、 are achieved filtered and unfiltered usingPVDF filters. Filtering using PTFE filters produced muchlower recoveries. This Practice does not account for theAPEOsadhered to particulates or the sample bottle.4.3 Nonylphenol polyethoxylates (NPnEO, 3 # n # 18),octylphenol polyethoxylates (OPnEO, 2 # n #
22、 12), andn-nonylphenol diethoxylate (n-NP2EO, surrogate) are identi-fied by retention time and one SRM transition. The targetanalytes and surrogates are quantitated using the SRM transi-tion by external calibration. The final report issued for eachsample lists their qualified concentration and the s
23、urrogaterecovery.5. Significance and Use5.1 This Practice has been developed in support of the USEPA Office of Water, Office of Science and Technology by theChicago Regional Laboratory (CRL).5.2 Nonylphenol (NP) and Octylphenol (OP) have beenshown to have toxic effects in aquatic organisms. The prom
24、i-nent source of NP and OP is from common commercialsurfactants which are longer chain APEOs. The most widelyused surfactant is nonylphenol polyethoxylate (NPnEO) whichhas an average ethoxylate chain length of nine. TheAPEOs arereadily biodegraded to form NP1EO, NP2EO, nonylphenolcarboxylate (NPEC)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD774220118750STANDARDPRACTICEFORDETERMINATIONOFNONYLPHENOLPOLYETHOXYLATESNPNEO N18ANDOCTYLPHENOLPOLYETHOXYLATESOPNEO

链接地址:http://www.mydoc123.com/p-527699.html