ASTM E72-2014 8784 Standard Test Methods of Conducting Strength Tests of Panels for Building Construction《建筑结构用板条的传导强度试验的标准试验方法》.pdf
《ASTM E72-2014 8784 Standard Test Methods of Conducting Strength Tests of Panels for Building Construction《建筑结构用板条的传导强度试验的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E72-2014 8784 Standard Test Methods of Conducting Strength Tests of Panels for Building Construction《建筑结构用板条的传导强度试验的标准试验方法》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E72 14Standard Test Methods ofConducting Strength Tests of Panels for BuildingConstruction1This standard is issued under the fixed designation E72; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.INTRODUCTIONSound engineering design of structures usi
3、ng existing or new materials requires accurate technicaldata on the strength and rigidity of the basic elements employed in various construction systems. It isthe purpose of these test methods to provide a systematic basis for obtaining engineering data onvarious construction elements and structural
4、 details of value to designers, builders, building officials,and others interested in this field. The results should closely approximate the performance in actualservice.1. Scope1.1 These test methods cover the following procedures fordetermining the structural properties of segments of wall, floor,
5、and roof constructions:SectionTest Specimens 3Loading 4Deformation Measurements 5Reports 6Precision and Accuracy 7TESTING WALLSSignificance and Use 8Compressive Load 9Tensile Load 10Transverse LoadSpecimen Horizontal 11Transverse LoadSpecimen Vertical 12Concentrated Load 13Impact LoadSee Test Method
6、s E695 and E661Racking LoadEvaluation of Sheathing Materialson a Standard Wood Frame14Racking LoadEvaluation of Sheathing Materials (Wet)on a Standard Wood Frame15TESTING FLOORSSignificance and Use 16Transverse Load 17Concentrated Load 18Impact LoadSee Test Methods E695 and E661TESTING ROOFSSectionS
7、ignificance and Use 19Transverse Load 20Concentrated Load 21APPENDIXTechnical Interpretation Appendix X11.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not c
8、onsidered standard.1.2.1 ExceptionSI units are used in Fig. 6.2. Referenced Documents2.1 ASTM Standards:2D2395 Test Methods for Density and Specific Gravity (Rela-tive Density) of Wood and Wood-Based MaterialsD4442 Test Methods for Direct Moisture Content Measure-ment of Wood and Wood-Base Materials
9、D7438 Practice for Field Calibration and Application ofHand-Held Moisture MetersE4 Practices for Force Verification of Testing MachinesE73 Practice for Static Load Testing of Truss AssembliesE564 Practice for Static Load Test for Shear Resistance ofFramed Walls for BuildingsE575 Practice for Reporti
10、ng Data from Structural Tests ofBuilding Constructions, Elements, Connections, and As-sembliesE661 Test Method for Performance of Wood and Wood-Based Floor and Roof Sheathing Under ConcentratedStatic and Impact Loads1These test methods are under the jurisdiction of ASTM Committee E06 onPerformance o
11、f Buildings and are the direct responsibility of Subcommittee E06.11on Horizontal and Vertical Structures/Structural Performance of Completed Struc-tures.Current edition approved June 1, 2014. Published August 2014. Originallyapproved in 1947. Last previous edition approved in 2013 as E72 13a. DOI:1
12、0.1520/E0072-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor
13、 Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1E695 Test Method of Measuring Relative Resistance ofWall, Floor, and Roof Construction to Impact LoadingE2126 Test Methods for Cyclic (Reversed) Load Test forShear Resistance of Vertical Elements of the Lateral ForceResisting Syste
14、ms for BuildingsE2309/E2309M Practices for Verification of DisplacementMeasuring Systems and Devices Used in Material TestingMachinesE2322 Test Method for Conducting Transverse and Concen-trated Load Tests on Panels used in Floor and RoofConstruction2.2 Other Document:3NIST Voluntary Product Standar
15、d PS20 American SoftwoodLumber Standard3. Test Specimens3.1 SizeThere shall be at least three specimens for eachtest. Specimens shall be constructed to represent sections of thewall, floor, or roof assembly. The specimens shall be represen-tative as to material and workmanship and shall be of thelar
16、gest practical size to predict structural performance attri-butes of the assembly. Unsymmetrical assemblies shall betested in each axis for which the results may be different.3.2 Length or HeightThe length or height of specimen foreach element shall be chosen to conform to the length or heightof tha
17、t element in actual use.3.3 WidthThe width of specimen shall be chosen, insofaras possible, to include several of the principal load-carryingmembers to ensure that the behavior under load will simulatethat under service conditions. With the exception of specimensfor the racking load test, the nomina
18、l width of wall specimensshall be 4 ft (1.2 m). The actual width of specimens shall be awhole number multiplied by the spacing of the principalload-carrying members except for prefabricated panels, forwhich the actual width shall be the width of panel used. If thestructural properties of a particula
19、r construction are to becompared with another construction, there should not be agreat difference in the actual widths of the specimens.3.4 AgeConstructions, such as concrete and masonry(brick, structural clay tile, concrete block) for which thestructural properties depend upon the age of the specim
20、en,shall be tested not less than 25 days nor more than 31 days afterfabrication. This age requirement applies also to plastered andstuccoed constructions.4. Loading4.1 ApparatusThe testing machine or load-measuring ap-paratus shall comply with the requirements prescribed inPractices E4.4.2 Applicati
21、on of LoadApply the load to all of thespecimens in any test in increments so chosen that a sufficientnumber of readings will be obtained to determine definitely theload-deformation curve (see Section 6). Record the initialreading of the load and the reading of the deformation, eitherwith no load on
22、the specimen or under a small initial load.Increase the load to the first increment and record the defor-mation. Unless otherwise specified, decrease the load to theinitial load and record the set (sometimes designated “perma-nent set”). Increase the load to two increments and record theset, when it
23、 is released to the initial load. Follow this sequenceof readings for three increments, four increments, and so forth,of load. When for each specimen the behavior of the specimenunder load indicates that the specimen might fail suddenly anddamage the deformation-measuring apparatus, remove thisappar
24、atus from the specimen and increase the load continu-ously until the maximum load that can be applied to thespecimen is determined.4.3 Duration of Load ApplicationExcept for racking tests,after each increment of load is applied, maintain the load levelas constant as possible for a period of 5 min (s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME7220148784STANDARDTESTMETHODSOFCONDUCTINGSTRENGTHTESTSOFPANELSFORBUILDINGCONSTRUCTION 建筑结构 板条 传导

链接地址:http://www.mydoc123.com/p-527614.html