《ASTM E398-2003(2009)e1 516 Standard Test Method for Water Vapor Transmission Rate of Sheet Materials Using Dynamic Relative Humidity Measurement《用动态相对湿度测量法测定薄板材料中水蒸气透过率的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E398-2003(2009)e1 516 Standard Test Method for Water Vapor Transmission Rate of Sheet Materials Using Dynamic Relative Humidity Measurement《用动态相对湿度测量法测定薄板材料中水蒸气透过率的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 398 03 (Reapproved 2009)1Standard Test Method forWater Vapor Transmission Rate of Sheet Materials UsingDynamic Relative Humidity Measurement1This standard is issued under the fixed designation E 398; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits information was revised editorially in May 2009.1. Scope1.1 This test metho
3、d covers dynamic evaluation of the rateof transfer of water vapor through a flexible barrier materialand allows conversion to the generally recognized units ofwater vapor transmission (WVT) as obtained by various othertest methods including the gravimetric method described inTest Methods E 96/E 96M.
4、1.2 LimitationsThis test method is limited to flexiblebarrier sheet materials composed of either completely hydro-phobic materials, or combinations of hydrophobic and hydro-philic materials having at least one surface that is hydrophobic.1.3 The minimum test value obtained by this test method islimi
5、ted by the leakage of water vapor past the clamping sealsof the test instrument. A reasonable value may be approxi-mately 0.01 g/24 hm2for any WVTR method including thedesiccant procedure of Test Methods E 96/E 96M at 37.8C,and 90 % relative humidity. This limit can be checked for eachinstrument wit
6、h an impervious specimen such as aluminumfoil. Calibration procedures can compensate for the leakagerate if so stated.1.4 This test method is not suitable for referee testing at thistime, but is suitable for control testing and material compari-son.1.5 Several other ASTM test methods are available t
7、o test asimilar property. This test method is unique in that it closelyduplicates typical product storage where a transfer of moisturefrom a package into the environment is allowed to proceedwithout constantly sweeping the environmental side with drygas. Methods with constantly swept dry sides inclu
8、de TestMethods F 1249, F 372, and F 1770.1.6 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of th
9、e user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 168 Terminology Relating to Thermal InsulationE 96/E 96M Test Methods for Water Vapor Transmission ofMate
10、rialsF17 Terminology Relating to Flexible Barrier PackagingF 372 Test Method for Water Vapor Transmission Rate ofFlexible Barrier Materials Using an Infrared DetectionTechniqueF 1249 Test Method for Water Vapor Transmission RateThrough Plastic Film and Sheeting Using a ModulatedInfrared SensorF 1770
11、 Test Method for Evaluation of Solubility, Diffusiv-ity, and Permeability of Flexible Barrier Materials to WaterVapor33. Terminology3.1 DefinitionsFor definitions of terms concerning thetransmission of water vapor refer to Terminologies C 168 andF17.4. Summary of Test Method4.1 The specimen is mount
12、ed between two chambers, one ofrelatively high relative humidity and the other of relatively lowrelative humidity. After conditioning and isolation of cham-bers, the rate at which the moisture increases within therelatively low relative humidity chamber over a predeterminedrange of interest is measu
13、red. This rate is compared to the rate1This test method is under the jurisdiction of ASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subcommittee F02.10 onPermeation. A previous version was under the jurisdiction of ASTM CommitteeC16.Current edition approved May 1
14、, 2009. Published June 2009. Originallyapproved in 1970. Last previous edition approved in 2003 as E 398 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the stan
15、dards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.for a calibration sample (calibrated gravim
16、etrically) and theWVTR is determined.5. Significance and Use5.1 No single set of test conditions can represent all climaticand use conditions, so this WVTR test method serves more tocompare different materials at a stated set of conditions than topredict their actual performance in the field under a
17、ny condi-tions.5.2 The water vapor transmission rate, under known andcarefully controlled conditions, may be used to evaluate thevapor barrier qualities of a sheet. Direct correlation of valuesobtained under different conditions of test temperature andrelative humidity will be valid provided the bar
18、rier materialunder test does not undergo changes in solid state (such as acrystalline transition or melting point) at or between theconditions of test.6. Apparatus6.1 The apparatus employed should have the followingelements:6.1.1 Test Cell, designed to clamp a defined sample areasufficiently large t
19、o be representative of the sample (an area of50 cm2has been shown to be satisfactory) between twochambers, one to contain an atmosphere of low relativehumidity (sensor-side chamber), and the other an atmosphereof higher relative humidity (humidified chamber) (see Fig. 1).6.1.2 Clamping Arrangement,
20、to allow rapid insertion andremoval of the test specimen equipped with gaskets againstwhich the specimen is held to the dry chamber by a clampingforce sufficient to resist leakage.6.1.3 Humidification Provision, for maintaining humidity inthe wet cell at the desired level. Where an atmosphere close
21、tosaturation is required, this may be achieved by means of areservoir of water or a saturated sponge provided there is aspacing 8 mm or less, between the water source and thespecimen and yet no direct contact. Other levels of relativehumidity may be obtained with saturated salt solutions or astream
22、of controlled humidified air.6.1.4 Air SourceAir dried below the operating humidityrange of the instrument (5 % relative humidity or less) shall beused as a purge for the sensor-side chamber. Various desiccantshave been found satisfactory as drying agents.6.1.5 Sensor, with rapid response and sensit
23、ivity capable ofdetecting changes in the moisture content of the gas within thedry chamber of 0.05 % relative humidity or less. This sensormay take any of a number of forms. For this purpose, thefollowing have been described in the literature: an electricalresistance element,4an electrolytic cell,5a
24、nd a beam ofinfrared radiation.66.1.6 Data Collection, a means to convert the sensorsmoisture-change response into a signal that can be used tocalculate the passage of moisture through the material undertest. This may take the form of registering the time required forthe signal to pass between two s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME39820032009E1516STANDARDTESTMETHODFORWATERVAPORTRANSMISSIONRATEOFSHEETMATERIALSUSINGDYNAMICRELATIVEHUMIDITYMEASUREMENT

链接地址:http://www.mydoc123.com/p-527546.html