1、Designation: E 336 08Standard Test Method forMeasurement of Airborne Sound Attenuation betweenRooms in Buildings1This standard is issued under the fixed designation E 336; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、 last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.INTRODUCTIONThis test method is part of a set of
3、 standards for evaluating the sound-insulating properties ofbuilding elements. It is designed to measure the sound isolation between two rooms or to estimatelower limits for sound transmission through a partition element installed as an interior part of abuilding. Others in the set cover the airborn
4、e sound transmission loss of an isolated partition elementin a controlled laboratory environment (Test Method E90), the laboratory measurement of impactsound transmission through floors (Test Method E 492), the measurement of impact sound transmis-sion in buildings (Test Method E 1007), the measurem
5、ent of sound transmission through buildingfacades and facade elements (Guide E 966), the measurement of sound transmission through acommon plenum between two rooms (Test Method E 1414), and the measurement of soundtransmission through door panels and systems (Test Method E 1408).1. Scope1.1 The soun
6、d isolation between two spaces in a building isdetermined by a combination of the direct transmission throughthe nominally separating building element (as normally mea-sured in a laboratory) and any transmission along a number ofindirect paths, usually referred to as flanking paths. Fig. 1illustrate
7、s the direct paths and some possible structural flankingpaths. Additional non-structural flanking paths may includetransmission through common air ducts between rooms, ordoors to the corridor from adjacent rooms.1.2 The main part of this test method defines procedures andmetrics to assess the sound
8、isolation between two rooms in abuilding separated by a common partition including both directand flanking transmission paths. Appropriate measures andtheir single number ratings are the noise reduction (NR) andnoise isolation class (NIC), the normalized noise reduction(NNR) and normalized noise iso
9、lation class (NNIC), and theapparent transmission loss (ATL) and apparent sound transmis-sion class (ASTC). With the exception of the ATL and ASTCunder specified conditions, these procedures are only appli-cable when both room volumes are less than 150 m3.NOTE 1The word “partition” in this test meth
10、od includes all types ofwalls, floors, or any other boundaries separating two spaces. The bound-aries may be permanent, operable, or movable.1.3 Annex A1 provides methods to assess the sound trans-mission through a partition or partition element with theinfluence of flanking transmission reduced. Th
11、ese methodsmay be used when it must be demonstrated that a partition hasachieved a specified minimum sound attenuation. The resultsare the field transmission loss (FTL) and field sound transmis-sion class (FSTC).1.4 Annex A2 provides methods to measure the soundisolation between portions of two room
12、s in a building separatedby a common partition including both direct and flanking pathswhen at least one of the rooms has a volume of 150 m3or more.The results are the noise reduction (NR) and noise isolationclass (NIC).1.5 This standard may involve hazardous materials, opera-tions, and equipment. T
13、his standard does not purport toaddress all of the safety concerns, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.1This test method is u
14、nder the jurisdiction ofASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.03 on Sound Transmission.Current edition approved Nov. 1, 2008. Published November 2008. Originallyapproved in 1971. Last previous edition approved in 2007 as E 336 0
15、7.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2. Referenced Documents2.1 ASTM Standards:2C 634 Terminology Relating to Building and Environmen-tal AcousticsE90 Test Method for Laboratory Measurement of AirborneSound Transmission
16、Loss of Building Partitions and Ele-mentsE 413 Classification for Rating Sound InsulationE 492 Test Method for Laboratory Measurement of ImpactSound Transmission Through Floor-Ceiling AssembliesUsing the Tapping MachineE 966 Guide for Field Measurements of Airborne SoundInsulation of Building Facade
17、s and Facade ElementsE 1007 Test Method for Field Measurement of TappingMachine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support StructuresE 1408 Test Method for Laboratory Measurement of theSound Transmission Loss of Door Panels and Door Sys-temsE 1414 Test Method f
18、or Airborne Sound Attenuation Be-tween Rooms Sharing a Common Ceiling PlenumE 2235 Test Method for Determination of Decay Rates forUse in Sound Insulation Test Methods2.2 ANSI Standards:3S1.4 Specification for Sound Level MetersS1.10 Pressure Calibration of Laboratory Standard PressureMicrophonesS1.
19、11 Specification for Octave-Band and Fractional-Octave-Band Analog and Digital FiltersS1.40 Specification and Verification Procedures for SoundCalibrators2.3 IEC Standard:4IEC 60804 Specification for Integrating-Averaging SoundLevel MetersIEC 60942 ElectroacousticsSound Calibrators3. Terminology3.1
20、The following terms used in this test method havespecific meanings that are defined in Terminology C 634:3.1.1 airborne sound; background noise; decay rate; decibel;diffuse sound field; field sound transmission class, FSTC; fieldtransmission loss, FTL; flanking transmission; pink noise;receiving roo
21、m; sabin; self-noise; sound absorption; soundattenuation; sound insulation; sound isolation; sound pressurelevel; sound transmission loss, TL; source roomNOTE 2The unqualified term average sound pressure level in thisdocument means that sound pressure levels were averaged over themeasurement region
22、for specified periods of time.3.2 Definitions of Terms Specific to This Standard:3.2.1 apparent transmission loss, ATL, nof a partitioninstalled in a building, in a specified frequency band isoperationally defined as:ATL 5 L12 L21 10 logSSA2D(1)where:S = the area of the partition common to both sour
23、ce andreceiving rooms,A2= the sound absorption in the receiving room,L1= the source room average sound pressure level, andL2= the receiving room average sound pressure levelresulting from the combined effect of direct andflanking transmission.3.2.1.1 DiscussionThroughout this test method, log istake
24、n to mean log10, unless otherwise indicated.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME3362008488STANDARDTESTMETHODFORMEASUREMENTOFAIRBORNESOUNDATTENUATIONBETWEENROOMSINBUILDINGSPDF

链接地址:http://www.mydoc123.com/p-527432.html