ASTM E331-2000(2016) 4846 Standard Test Method for Water Penetration of Exterior Windows Skylights Doors and Curtain Walls by Uniform Static Air Pressure Difference《采用统一静态空气压差法测定外窗.pdf
《ASTM E331-2000(2016) 4846 Standard Test Method for Water Penetration of Exterior Windows Skylights Doors and Curtain Walls by Uniform Static Air Pressure Difference《采用统一静态空气压差法测定外窗.pdf》由会员分享,可在线阅读,更多相关《ASTM E331-2000(2016) 4846 Standard Test Method for Water Penetration of Exterior Windows Skylights Doors and Curtain Walls by Uniform Static Air Pressure Difference《采用统一静态空气压差法测定外窗.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E331 00 (Reapproved 2016)Standard Test Method forWater Penetration of Exterior Windows, Skylights, Doors,and Curtain Walls by Uniform Static Air PressureDifference1This standard is issued under the fixed designation E331; the number immediately following the designation indicates the ye
2、ar oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. De
3、partment of Defense.1. Scope1.1 This test method covers the determination of the resis-tance of exterior windows, curtain walls, skylights, and doorsto water penetration when water is applied to the outdoor faceand exposed edges simultaneously with a uniform static airpressure at the outdoor face hi
4、gher than the pressure at theindoor face.1.2 This test method is applicable to any curtain-wall area orto windows, skylights, or doors alone.1.3 This test method addresses water penetration through amanufactured assembly. Water that penetrates the assembly,but does not result in a failure as defined
5、 herein, may haveadverse effects on the performance of contained materials suchas sealants and insulating or laminated glass. This test methoddoes not address these issues.1.4 The proper use of this test method requires a knowledgeof the principles of pressure measurement.1.5 The values stated in SI
6、 units are to be regarded as thestandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use.
7、It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see 7.1.2. Referenced Documents2.1 ASTM Standards:2E631 Terminology of Building Construct
8、ions3. Terminology3.1 DefinitionsFor definitions of general terms relating tobuilding construction used in this test method, see TerminologyE631.3.2 Definitions of Terms Specific to This Standard:3.2.1 specimen, nthe entire assembled unit submitted fortest as described in Section 8.3.2.2 test pressu
9、re difference, nthe specified difference instatic air pressure across the closed and locked or fixedspecimen expressed as Pascals (lbf/ft2).3.2.3 water penetration, npenetration of water beyond aplane parallel to the glazing (the vertical plane) intersecting theinnermost projection of the test speci
10、men, not includinginterior trim and hardware, under the specified conditions of airpressure difference across the specimen. For products withnon-planer glazing surfaces (domes, vaults, pyramids, etc.), theplane defining water penetration is the plane defined by theinnermost edges of the unit frame.4
11、. Summary of Test Method4.1 This test method consists of sealing the test specimeninto or against one face of a test chamber, supplying air to orexhausting air from the chamber at the rate required tomaintain the test pressure difference across the specimen, whilespraying water onto the outdoor face
12、 of the specimen at therequired rate and observing any water penetration.1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.51on Performance of Windows, Doors, Skylights and Curtain Walls.Current edition a
13、pproved Aug. 1, 2016. Published August 2016. Originallyapproved in 1967. Last previous edition approved in 2009 as E331 00(2009). DOI:10.1520/E0331-00R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMS
14、tandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Significance and Use5.1 This test method is a standard procedure for determiningthe resist
15、ance to water penetration under uniform static airpressure differences. The air-pressure differences acting acrossa building envelope vary greatly. These factors should be fullyconsidered prior to specifying the test pressure difference to beused.NOTE 1In applying the results of tests by this test m
16、ethod, note thatthe performance of a wall or its components, or both, may be a functionof proper installation and adjustment. In service, the performance will alsodepend on the rigidity of supporting construction and on the resistance ofcomponents to deterioration by various causes, vibration, therm
17、al expan-sion and contraction, etc. It is difficult to simulate the identical complexwetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increas-ing wind velocity, and lateral or upward moving air and water. Somedesign
18、s are more sensitive than others to this upward moving water.NOTE 2This test method does not identify unobservable liquid waterwhich may penetrate into the test specimen.6. Apparatus6.1 The description of apparatus in this section is general innature and any arrangement of equipment capable of perfo
19、rm-ing the test procedure within the allowable tolerances ispermitted.6.2 Major Components (Fig. 1):6.2.1 Test ChamberA test chamber or box with anopening, a removable mounting panel, or one open side inwhich or against which the specimen is installed and sealed. Atleast one static pressure tap shal
20、l be provided to measure thechamber pressure, and shall be so located that the reading isunaffected by the velocity of the air supply to or from thechamber. The air supply opening into the chamber shall bearranged so that the air does not impinge directly on the testspecimen with any significant vel
21、ocity. A means of access intothe chamber may be provided to facilitate adjustments andobservations after the specimen has been installed.NOTE 1For a negative pressure system, the water-spray grid would be located outside the chamber and the air supply would be replaced by anair-exhaust system.FIG. 1
22、 General Arrangement of the Water Leakage Apparatus Positive Chamber SystemE331 00 (2016)26.2.2 Air SystemA controllable blower, compressed airsupply, exhaust system, or reversible blower designed toprovide the required maximum air-pressure difference acrossthe specimen. The system must provide esse
23、ntially constantairflow at a fixed pressure for the required test period.6.2.3 Pressure-Measuring ApparatusA device to measurethe test pressure difference within a tolerance of 62% or62.5 Pa (60.01 in. of water column), whichever is greater.6.2.4 Water-Spray SystemThe water-spray system shalldeliver
24、 water uniformly against the exterior surface of the testspecimen at a minimum rate of 3.4 L m2 min(5.0 U.S. gal ft2 h).6.2.4.1 The water-spray system shall have nozzles spacedon a uniform grid, located at a uniform distance from the testspecimen, and shall be adjustable to provide the specifiedquan
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME331200020164846STANDARDTESTMETHODFORWATERPENETRATIONOFEXTERIORWINDOWSSKYLIGHTSDOORSANDCURTAINWALLSBYUNIFORMSTATICAIRPRESSUREDIFFERENCE

链接地址:http://www.mydoc123.com/p-527428.html