ASTM E331-2000(2009) 459 Standard Test Method for Water Penetration of Exterior Windows Skylights Doors and Curtain Walls by Uniform Static Air Pressure Difference《用统一静态气压差法测定外窗、天窗.pdf
《ASTM E331-2000(2009) 459 Standard Test Method for Water Penetration of Exterior Windows Skylights Doors and Curtain Walls by Uniform Static Air Pressure Difference《用统一静态气压差法测定外窗、天窗.pdf》由会员分享,可在线阅读,更多相关《ASTM E331-2000(2009) 459 Standard Test Method for Water Penetration of Exterior Windows Skylights Doors and Curtain Walls by Uniform Static Air Pressure Difference《用统一静态气压差法测定外窗、天窗.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 331 00 (Reapproved 2009)Standard Test Method forWater Penetration of Exterior Windows, Skylights, Doors,and Curtain Walls by Uniform Static Air PressureDifference1This standard is issued under the fixed designation E 331; the number immediately following the designation indicates the
2、year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Depar
3、tment of Defense.1. Scope1.1 This test method covers the determination of the resis-tance of exterior windows, curtain walls, skylights, and doorsto water penetration when water is applied to the outdoor faceand exposed edges simultaneously with a uniform static airpressure at the outdoor face highe
4、r than the pressure at theindoor face.1.2 This test method is applicable to any curtain-wall area orto windows, skylights, or doors alone.1.3 This test method addresses water penetration through amanufactured assembly. Water that penetrates the assembly,but does not result in a failure as defined he
5、rein, may haveadverse effects on the performance of contained materials suchas sealants and insulating or laminated glass. This test methoddoes not address these issues.1.4 The proper use of this test method requires a knowledgeof the principles of pressure measurement.1.5 The values stated in SI un
6、its are to be regarded as thestandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
7、is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see 7.1.2. Referenced Documents2.1 ASTM Standards:2E 631 Terminology of Building Constructio
8、ns3. Terminology3.1 DefinitionsFor definitions of general terms relating tobuilding construction used in this test method, see TerminologyE 631.3.2 Definitions of Terms Specific to This Standard:3.2.1 specimen, nthe entire assembled unit submitted fortest as described in Section 8.3.2.2 test pressur
9、e difference, nthe specified difference instatic air pressure across the closed and locked or fixedspecimen expressed as pascals (lbf/ft2).3.2.3 water penetration, npenetration of water beyond aplane parallel to the glazing (the vertical plane) intersecting theinnermost projection of the test specim
10、en, not includinginterior trim and hardware, under the specified conditions of airpressure difference across the specimen. For products withnon-planer glazing surfaces (domes, vaults, pyramids, etc.), theplane defining water penetration is the plane defined by theinnermost edges of the unit frame.4.
11、 Summary of Test Method4.1 This test method consists of sealing the test specimeninto or against one face of a test chamber, supplying air to orexhausting air from the chamber at the rate required tomaintain the test pressure difference across the specimen, whilespraying water onto the outdoor face
12、of the specimen at therequired rate and observing any water penetration.5. Significance and Use5.1 This test method is a standard procedure for determiningthe resistance to water penetration under uniform static airpressure differences. The air-pressure differences acting acrossa building envelope v
13、ary greatly. These factors should be fullyconsidered prior to specifying the test pressure difference to beused.NOTE 1In applying the results of tests by this test method, note thatthe performance of a wall or its components, or both, may be a functionof proper installation and adjustment. In servic
14、e, the performance will alsodepend on the rigidity of supporting construction and on the resistance ofcomponents to deterioration by various causes, vibration, thermal expan-sion and contraction, etc. It is difficult to simulate the identical complex1This test method is under the jurisdiction of AST
15、M Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.51on Performance of Windows, Doors, Skylights, and Curtain Walls.Current edition approved Feb. 1, 2009. Published March 2009. Originallyapproved in 1967. Last previous edition approved in 2000 as E 331 00
16、.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box
17、 C700, West Conshohocken, PA 19428-2959, United States.wetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increas-ing wind velocity, and lateral or upward moving air and water. Somedesigns are more sensitive than othe
18、rs to this upward moving water.NOTE 2This test method does not identify unobservable liquid waterwhich may penetrate into the test specimen.6. Apparatus6.1 The description of apparatus in this section is general innature and any arrangement of equipment capable of perform-ing the test procedure with
19、in the allowable tolerances ispermitted.6.2 Major Components (Fig. 1):6.2.1 Test ChamberA test chamber or box with an open-ing, a removable mounting panel, or one open side in which oragainst which the specimen is installed and sealed. At least onestatic pressure tap shall be provided to measure the
20、 chamberpressure, and shall be so located that the reading is unaffectedby the velocity of the air supply to or from the chamber. The airsupply opening into the chamber shall be arranged so that theair does not impinge directly on the test specimen with anysignificant velocity. A means of access int
21、o the chamber maybe provided to facilitate adjustments and observations after thespecimen has been installed.6.2.2 Air SystemA controllable blower, compressed airsupply, exhaust system, or reversible blower designed toprovide the required maximum air-pressure difference acrossthe specimen. The syste
22、m must provide essentially constantairflow at a fixed pressure for the required test period.6.2.3 Pressure-Measuring ApparatusA device to measurethe test pressure difference within a tolerance of 62% or62.5 Pa (60.01 in. of water column), whichever is greater.6.2.4 Water-Spray SystemThe water-spray
23、system shalldeliver water uniformly against the exterior surface of the testspecimen at a minimum rate of 3.4 L/m2 min (5.0 U.S. gal/ft2 h).6.2.4.1 The water-spray system shall have nozzles spacedon a uniform grid, located at a uniform distance from the testspecimen, and shall be adjustable to provi
24、de the specifiedquantity of water in such a manner as to wet all of the testspecimen uniformly and to wet those areas vulnerable to waterpenetration. If additional nozzles are required to provideNOTE 1For a negative pressure system, the water-spray grid would be located outside the chamber and the a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME33120002009459STANDARDTESTMETHODFORWATERPENETRATIONOFEXTERIORWINDOWSSKYLIGHTSDOORSANDCURTAINWALLSBYUNIFORMSTATICAIRPRESSUREDIFFERENCE

链接地址:http://www.mydoc123.com/p-527427.html