ASTM E330-2002(2010) 1875 Standard Test Method for Structural Performance of Exterior Windows Doors Skylights and Curtain Walls by Uniform Static Air Pressure Difference《用统一静态气压差法测.pdf
《ASTM E330-2002(2010) 1875 Standard Test Method for Structural Performance of Exterior Windows Doors Skylights and Curtain Walls by Uniform Static Air Pressure Difference《用统一静态气压差法测.pdf》由会员分享,可在线阅读,更多相关《ASTM E330-2002(2010) 1875 Standard Test Method for Structural Performance of Exterior Windows Doors Skylights and Curtain Walls by Uniform Static Air Pressure Difference《用统一静态气压差法测.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E330 02 (Reapproved 2010)Standard Test Method forStructural Performance of Exterior Windows, Doors,Skylights and Curtain Walls by Uniform Static Air PressureDifference1This standard is issued under the fixed designation E330; the number immediately following the designation indicates th
2、e year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Dep
3、artment of Defense.1. Scope1.1 This test method describes the determination of thestructural performance of exterior windows, doors, skylights,and curtain walls under uniform static air pressure differences,using a test chamber. This test method is applicable to curtainwall assemblies including, but
4、 not limited to, metal, glass,masonry, and stone components.1.2 This test method is intended only for evaluating thestructural performance associated with the specified test speci-men and not the structural performance of adjacent construc-tion.1.3 The proper use of this test method requires a knowl
5、edgeof the principles of pressure and deflection measurement.1.4 This test method describes the apparatus and the proce-dure to be used for applying uniformly distributed test loads toa specimen.1.4.1 Procedure A (see 11.2) shall be used when a load-deflection curve is not required.1.4.2 Procedure B
6、 (see 11.3) shall be used when a load-deflection curve is required.1.5 The text of this standard references notes and footnoteswhich provide explanatory materials. These notes and foot-notes (excluding those in tables and figures) shall not beconsidered as requirements of the standard.1.6 The values
7、 stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with
8、its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 7.2. Referenced Documents22.1 ASTM Standards:3E631 Terminology of Bu
9、ilding ConstructionsE997 Test Method for Structural Performance of Glass inExterior Windows, Curtain Walls, and Doors Under theInfluence of Uniform Static Loads by Destructive MethodsE998 Test Method for Structural Performance of Glass inWindows, Curtain Walls, and Doors Under the Influence ofUnifor
10、m Static Loads by Nondestructive MethodE1233 Test Method for Structural Performance of ExteriorWindows, Doors, Skylights, and Curtain Walls by CyclicAir Pressure DifferentialE1300 Practice for Determining Load Resistance of Glassin BuildingsE1886 Test Method for Performance of Exterior Windows,Curta
11、in Walls, Doors, and Impact Protective SystemsImpacted by Missile(s) and Exposed to Cyclic PressureDifferentialsE1996 Specification for Performance of Exterior Windows,Curtain Walls, Doors, and Impact Protective SystemsImpacted by Windborne Debris in Hurricanes2.2 ASCE Standard:4ASCE 7 Minimum Desig
12、n Loads for Buildings and OtherStructures3. Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nology E631, unless otherwise indicated.3.2 Definitions of Terms Specific to This Standard:3.2.1 design wind loadthe uniform static air pressuredifferences, inward and outward, for which th
13、e specimen1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.51on Performance of Windows, Doors, Skylights and Curtain Walls.Current edition approved April 1, 2010. Published May 2010. Originallyapproved i
14、n 1967. Last previous edition approved in 2002 as E330 02. DOI:10.1520/E0330-02R10.2Additional information on curtain wall assemblies can be obtained from theAmerican Architectural Manufacturers Association (AAMA), 1827 Walden OfficeSquare, Suite 550, Schaumburg, IL 60173, http:/www.aamanet.org.3For
15、 referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from American Society of Civil Engineers (ASCE), 1801
16、AlexanderBell Dr., Reston, VA 20191, http:/www.asce.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.would be designed under service load conditions using con-ventional wind engineering specifications and concepts, ex-pressed in p
17、ascals (or pounds-force per square foot). Thispressure is determined by either analytical or wind-tunnelprocedures (such as are specified in ASCE 7).3.2.2 permanent deformation, nthe displacement orchange in dimension of the specimen after the applied load hasbeen removed and the specimen has relaxe
18、d for the specifiedperiod of time.3.2.3 proof loada test load multiplied by a factor of safety.3.2.4 stick system, na curtain wall assembly composed ofindividually framed continuous members, vertical mullions,and horizontal rails that are installed in a sequential, piece-by-piece process. The comple
19、ted system is assembled entirely inthe field.3.2.5 structural distressa change in condition of thespecimen indicative of deterioration or incipient failure, suchas cracking, local yielding, fastener loosening, or loss ofadhesive bond.3.2.6 test loadthe specified difference in static air pressure(pos
20、itive or negative) for which the specimen is to be tested,expressed in pascals (or pounds-force per square foot).3.2.7 test specimen, nthe entire assembled unit submittedfor test (as described in Section 8).3.2.8 unit/panel system, na curtain wall assembly com-posed of pre-assembled groups of indivi
21、dual framing members.The completed system is designed to be modular, transport-able, and installed as a finished assembly.4. Summary of Test Method4.1 This test method consists of sealing the test specimeninto or against one face of a test chamber, supplying air to orexhausting air from the chamber
22、according to a specific testloading program, at the rate required to maintain the testpressure difference across the specimen, and observing, mea-suring, and recording the deflection, deformations, and natureof any distress or failures of the specimen.5. Significance and Use5.1 This test method is a
23、 standard procedure for determiningstructural performance under uniform static air pressure differ-ence. This typically is intended to represent the effects of awind load on exterior building surface elements. The actualloading on building surfaces is quite complex, varying withwind direction, time,
24、 height above ground, building shape,terrain, surrounding structures, and other factors. The resis-tance of many windows, curtain walls, and door assemblies towind loading is also complex and depends on the completehistory of load, magnitude, duration, and repetition. Thesefactors are discussed in A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME330200220101875STANDARDTESTMETHODFORSTRUCTURALPERFORMANCEOFEXTERIORWINDOWSDOORSSKYLIGHTSANDCURTAINWALLSBYUNIFORMSTATICAIRPRESSUREDIFFERENCE

链接地址:http://www.mydoc123.com/p-527425.html