ASTM E330-2002 Standard Test Method for Structural Performance of Exterior Windows Doors Skylights and Curtain Walls by Uniform Static Air Pressure Difference《用统一静态气压差法测定外窗、门、天窗和幕墙.pdf
《ASTM E330-2002 Standard Test Method for Structural Performance of Exterior Windows Doors Skylights and Curtain Walls by Uniform Static Air Pressure Difference《用统一静态气压差法测定外窗、门、天窗和幕墙.pdf》由会员分享,可在线阅读,更多相关《ASTM E330-2002 Standard Test Method for Structural Performance of Exterior Windows Doors Skylights and Curtain Walls by Uniform Static Air Pressure Difference《用统一静态气压差法测定外窗、门、天窗和幕墙.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 330 02Standard Test Method forStructural Performance of Exterior Windows, Doors,Skylights and Curtain Walls by Uniform Static Air PressureDifference1This standard is issued under the fixed designation E 330; the number immediately following the designation indicates the year oforigina
2、l adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defe
3、nse.1. Scope1.1 This test method describes the determination of thestructural performance of exterior windows, doors, skylights,and curtain walls under uniform static air pressure differences,using a test chamber. This test method is applicable to curtainwall assemblies including, but not limited to
4、, metal, glass,masonry, and stone components.1.2 This test method is intended only for evaluating thestructural performance associated with the specified test speci-men and not the structural performance of adjacent construc-tion.1.3 The proper use of this test method requires a knowledgeof the prin
5、ciples of pressure and deflection measurement.1.4 This test method describes the apparatus and the proce-dure to be used for applying uniformly distributed test loads toa specimen.1.4.1 Procedure A (see 11.2) shall be used when a load-deflection curve is not required.1.4.2 Procedure B (see 11.3) sha
6、ll be used when a load-deflection curve is required.1.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsi
7、bility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 7.1.7 The text of this standard references notes and footnoteswhich provide explanatory materi
8、als. These notes and foot-notes (excluding those in tables and figures) shall not beconsidered as requirements of the standard.2. Referenced Documents22.1 ASTM Standards:E 631 Terminology of Building Constructions3E 997 Test Method for Structural Performance of Glass inExterior Windows, Curtain Wall
9、s, and Doors Under theInfluence of Uniform Static Loads by Destructive Meth-ods3E 998 Test Method for Structural Performance of Glass inWindows, Curtain Walls, and Doors Under the Influence ofUniform Static Loads by Nondestructive Method3E 1233 Test Method for Structural Performance of ExteriorWindo
10、ws, Curtain Walls, and Doors by CyclicAir PressureDifferential3E 1300 Practice for Determining Load Resistance of Glassin Buildings3E 1886 Test Method for Performance of Exterior Windows,Curtain Walls, Doors, and Storm Shutters Impacted byMissile(s) and Exposed to Cyclic Pressure Differentials4E 199
11、6 Specification for Performance of Exterior Windows,Curtain Walls, Doors, and Storm Shutters Impacted byWindborne Debris in Hurricanes41This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.51on Performance of
12、 Windows, Doors, Skylights and Curtain Walls.Current edition approved Nov. 10, 2002. Published November 2002. Originallyapproved in 1967. Last previous edition approved in 1997 as E 330 97e1.2Additional information on curtain wall assemblies can be obtained from theAmerican Architectural Manufacture
13、rs Association, 1827 Walden Office Square,Suite 550, Schaumburg, IL 60173.3Annual Book of ASTM Standards, Vol 04.11.4Annual Book of ASTM Standards, Vol 04.12.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2.2 ASCE Standard:ASCE 7 Mi
14、nimum Design Loads for Buildings and OtherStructures53. Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nology E 631, unless otherwise indicated.3.2 Definitions of Terms Specific to This Standard:3.2.1 design wind loadthe uniform static air pressuredifferences, inward and outward,
15、 for which the specimenwould be designed under service load conditions using con-ventional wind engineering specifications and concepts, ex-pressed in pascals (or pounds-force per square foot). Thispressure is determined by either analytical or wind-tunnelprocedures (such as are specified in ASCE 7)
16、.3.2.2 permanent deformation, nthe displacement orchange in dimension of the specimen after the applied load hasbeen removed and the specimen has relaxed for the specifiedperiod of time.3.2.3 proof loada test load multiplied by a factor of safety.3.2.4 stick system, na curtain wall assembly composed
17、 ofindividually framed continuous members, vertical mullions,and horizontal rails that are installed in a sequential, piece-by-piece process. The completed system is assembled entirely inthe field.3.2.5 structural distressa change in condition of thespecimen indicative of deterioration or incipient
18、failure, suchas cracking, local yielding, fastener loosening, or loss ofadhesive bond.3.2.6 test loadthe specified difference in static air pressure(positive or negative) for which the specimen is to be tested,expressed in pascals (or pounds-force per square foot).3.2.7 test specimen, nthe entire as
19、sembled unit submittedfor test (as described in Section 8).3.2.8 unit/panel system, na curtain wall assembly com-posed of pre-assembled groups of individual framing members.The completed system is designed to be modular, transport-able, and installed as a finished assembly.4. Summary of Test Method4
20、.1 This test method consists of sealing the test specimeninto or against one face of a test chamber, supplying air to orexhausting air from the chamber according to a specific testloading program, at the rate required to maintain the testpressure difference across the specimen, and observing, mea-su
21、ring, and recording the deflection, deformations, and natureof any distress or failures of the specimen.5. Significance and Use5.1 This test method is a standard procedure for determiningstructural performance under uniform static air pressure differ-ence. This typically is intended to represent the
22、 effects of awind load on exterior building surface elements. The actualloading on building surfaces is quite complex, varying withwind direction, time, height above ground, building shape,terrain, surrounding structures, and other factors. The resis-tance of many windows, curtain walls, and door as
23、semblies towind loading is also complex and depends on the completehistory of load, magnitude, duration, and repetition. Thesefactors are discussed in ASCE 7 and in the literature (1-8).65.2 Design wind velocities are selected for particular geo-graphic locations and probabilities of occurrence base
24、d on datafrom wind velocity maps such as are provided in ASCE 7.These wind velocities are translated into uniform static airpressure differences and durations acting inward and outward.Complexities of wind pressures, as related to building design,wind intensity versus duration, frequency of occurren
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便