1、Designation: E308 12E308 13Standard Practice forComputing the Colors of Objects by Using the CIE System1This standard is issued under the fixed designation E308; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.INTRODUCTIONStandard tables (Tables 14) of color matching
3、functions and illuminant spectral power distributionshave since 1931 been defined by the CIE, but the CIE has eschewed the role of preparing tables oftristimulus weighting factors for the convenient calculation of tristimulus values. There havesubsequently appeared numerous compilations of tristimul
4、us weighting factors in the literature withdisparity of data resulting from, for example, different selections of wavelength intervals and methodsof truncating abbreviated wavelength ranges. In 1970, Foster et al. (1)2 proposed conventions tostandardize these two features, and Stearns (2) published
5、a more complete set of tables. Stearns workand later publications such as the 1985 revision of E308 have greatly reduced the substantial variationsin methods for tristimulus computation that existed several decades ago.The disparities among earlier tables were largely caused by the introduction of c
6、omputations basedon 20-nm wavelength intervals. With the increasing precision of modern instruments, there is alikelihood of a need for tables for narrower wavelength intervals. Stearns tables, based on a 10-nminterval, did not allow the derivation of consistent tables with wavelength intervals less
7、 than 10 nm.The 1-nm table must be designated the basic table if others with greater wavelength intervals are tohave the same white point, and this was the reason for the 1985 revision of E308, resulting in tablesthat are included in the present revision as Tables 5.The 1994 revision was made in ord
8、er to introduce to the user a method of reducing the dependenceof the computed tristimulus values on the bandpass of the measuring instrument, using methods thatare detailed in this practice.1. Scope1.1 This practice provides the values and practical computation procedures needed to obtain CIE trist
9、imulus values fromspectral reflectance, transmittance, or radiance data for object-color specimens.1.2 Procedures and tables of standard values are given for computing from spectral measurements the CIE tristimulus valuesX, Y, Z, and chromaticity coordinates x, y for the CIE 1931 standard observer a
10、nd X10, Y10, Z10 and x10. y10 for the CIE 1964supplementary standard observer.1.3 Standard values are included for the spectral power of six CIE standard illuminants and three CIE recommended fluorescentilluminants.1.4 Procedures are included for cases in which data are available only in more limite
11、d wavelength ranges than thoserecommended, or for a measurement interval wider than that recommended by the CIE. This practice is applicable to spectral dataobtained in accordance with Practice E1164 with 1-, 5-, 10-, or 20-nm measurement interval.1.5 Procedures are included for cases in which the s
12、pectral data are, and those in which they are not, corrected for bandpassdependence. For the uncorrected cases, it is assumed that the spectral bandpass of the instrument used to obtain the data wasapproximately equal to the measurement interval and was triangular in shape. These choices are believe
13、d to correspond to the mostwidely used industrial practice.1 This practice is under the jurisdiction of ASTM Committee E12 on Color and Appearance and is the direct responsibility of Subcommittee E12.04 on Color andAppearance Analysis.Current edition approved July 1, 2012Oct. 1, 2013. Published Dece
14、mber 2012November 2013. Originally approved in 1966. Last previous edition approved in 20082012as E308 08.E308 12. DOI: 10.1520/E0308-12.10.1520/E0308-13.2 The boldface numbers in parentheses refer to the list of references at the end of this practice.This document is not an ASTM standard and is int
15、ended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the curr
16、ent versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States11.6 This practice includes procedures for conversion of results to color spaces that are part of
17、 the CIE system, such as CIELABand CIELUV (3). Equations for calculating color differences in these and other systems are given in Practice D2244.1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.8 This standard does not p
18、urport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.8 This standard does not purport to address
19、 all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D2244 Practice for
20、Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color CoordinatesE284 Terminology of AppearanceE313 Practice for Calculating Yellowness and Whiteness Indices from Instrumentally Measured Color CoordinatesE1164 Practice for Obtaining Spectrometric Data for Object-Co
21、lor EvaluationE2022 Practice for Calculation of Weighting Factors for Tristimulus IntegrationE2729 Practice for Rectification of Spectrophotometric Bandpass Differences2.2 ANSI Standard:PH2.23 Lighting Conditions for Viewing Photographic Color Prints and Transparencies42.3 CIE/ISO Standards:CIE Stan
22、dard S 001/ISOISO Standard 11664-1:2007(E)/CIE S 013-1/E:2006 IS 10526,Standard ColorimetricIlluminantsObservers4,5CIE Standard S 002/ISOISO Standard 11664-2:2007(E)/CIE S 014-2/E:2006 IS 10527, Colorimetric ObserversIlluminants4,5CIE Standard D 001,D 001 Colorimetric Illuminants and Observers (Disk
23、)52.4 ASTM Adjuncts:Computer disk containing Tables 5 and 663. Terminology3.1 Definitions of terms in Terminology E284 are applicable to this practice (see also Ref (4).3.2 Definitions:3.2.1 bandpass, adjhaving to do with a passband.3.2.2 bandwidth, nthe width of a passband at its half-peak transmit
24、tance.3.2.3 chromaticity, nthe color quality of a color stimulus definable by its chromaticity coordinates.3.2.4 chromaticity coordinates, nthe ratio of each of the tristimulus values of a psychophysical color (see section 3.2.7.11)to the sum of the tristimulus values.3.2.4.1 DiscussionIn the CIE 19
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME3082013RED6815STANDARDPRACTICEFORCOMPUTINGTHECOLORSOFOBJECTSBYUSINGTHECIESYSTEM CIE 系统 计算 物体 颜色

链接地址:http://www.mydoc123.com/p-527366.html