ASTM E288-2010(2017) 8125 Standard Specification for Laboratory Glass Volumetric Flasks《实验室玻璃量瓶的标准规格》.pdf
《ASTM E288-2010(2017) 8125 Standard Specification for Laboratory Glass Volumetric Flasks《实验室玻璃量瓶的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM E288-2010(2017) 8125 Standard Specification for Laboratory Glass Volumetric Flasks《实验室玻璃量瓶的标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E288 10 (Reapproved 2017)Standard Specification forLaboratory Glass Volumetric Flasks1This standard is issued under the fixed designation E288; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers requirements for gla
3、ss volu-metric flasks of precision and general-purpose grades suitablefor laboratory purposes.1.1.1 Class AEach flask of precision grade shall bemarked with the letter “A” to signify compliance with appli-cable construction and accuracy requirements. Flasks may bemarked with an identification number
4、 (serial number) at theoption of the manufacturer.1.1.2 Class BGeneral purpose flasks are of the same basicdesign as Class A flasks. However, volumetric tolerances forClass B flasks shall be within twice the specified range allowedfor Class A flasks. These flasks need not be marked with theirclass d
5、esignation.NOTE 1Specifications for micro volumetric flasks in sizes from 1 mLto 25 mL, inclusive, are given in Specification E237.NOTE 2The Twelfth General (International) Conference on Weightsand Measures redefined the litre as a “special name for the cubicdecimetre,” but agreed to permit continua
6、nce of the terms litre, millilitre,and mL, except in association with measurements of the highest precision.For volumetric glassware the difference between the old and newmeanings of litre is negligible. Therefore, either mL or cm3may bemarked on ware covered by this Specification.1.1.3 Special Size
7、 FlasksPrecision grade flasks may bemanufactured with nominal capacities not listed in this stan-dard. Such flasks shall be considered “Class A” flasks, pro-vided they meet the accuracy tolerance of the next largest“Class A” flask appearing in Table 1 and comply with themarking requirements of 1.1.1
8、.1.1.4 Wide-Mouth FlasksRequirements for insertion oftablets or capsules for assay dilution and to accommodateaccess of larger diameter pipets require volumetric flasks withlarger necks. These flasks appear in Table 2. These flasks shallconform to the marking requirements of 1.1.1.Additionally, thea
9、ccuracy tolerance shall be marked on each “Class A” wide-mouth flask.1.1.5 Special Size Wide-Mouth FlasksPrecision gradewide-mouth flasks may be manufactured with nominal capaci-ties not listed in this standard. Such flasks shall be considered“Class A” flasks provided they meet the accuracy toleranc
10、e ofthe next largest “Class A” wide-mouth flask appearing in Table2 and the marking requirements of 1.1.4.1.2 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of Intern
11、ational Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E237 Specification for Laboratory Glass MicrovolumetricVessels (Volumetric Flasks and Centrifuge Tubes)E438 Specification for Gl
12、asses in Laboratory ApparatusE542 Practice for Calibration of Laboratory VolumetricApparatusE675 Specification for Interchangeable Taper-Ground Stop-cocks And StoppersE694 Specification for Laboratory Glass Volumetric Appa-ratusE920 Specification for Commercially Packaged LaboratoryApparatusE921 Spe
13、cification for Export Packaged Laboratory Appa-ratusE1133 Practice for Performance Testing of Packaged Labo-ratory Apparatus for United States Government Procure-mentsE1157 Specification for Sampling and Testing of ReusableLaboratory Glassware3. General Requirements3.1 CalibrationFlasks shall be cal
14、ibrated in accordancewith the methods outlined in Practice E542.1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Subcommittee E41.01 onLaboratory Ware and Supplies.Current edition approved Nov. 1, 2017. Published December
15、2017. Originallyapproved in 1965. Last previous edition approved in 2010 as E288 10. DOI:10.1520/E0288-10R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the sta
16、ndards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the De
17、cision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.14. Design4.1 Flasks shall be designed in accordance with Specifica-tions E438 and E694. Flask necks may be designed with
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME288201020178125STANDARDSPECIFICATIONFORLABORATORYGLASSVOLUMETRICFLASKS 实验室 玻璃 量瓶 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-527315.html