《ASTM E283-2004 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen《通过.pdf》由会员分享,可在线阅读,更多相关《ASTM E283-2004 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen《通过.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 283 04Standard Test Method forDetermining Rate of Air Leakage Through Exterior Windows,Curtain Walls, and Doors Under Specified PressureDifferences Across the Specimen1This standard is issued under the fixed designation E 283; the number immediately following the designation indicates
2、 the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the
3、 Department of Defense.1. Scope1.1 This test method covers a standard laboratory procedurefor determining the air leakage rates of exterior windows,curtain walls, and doors under specified differential pressureconditions across the specimen. The test method described isfor tests with constant temper
4、ature and humidity across thespecimen.1.2 This laboratory procedure is applicable to exteriorwindows, curtain walls, and doors and is intended to measureonly such leakage associated with the assembly and not theinstallation. The test method can be adapted for the latterpurpose.NOTE 1Performing tests
5、 at non-ambient conditions or with a tem-perature differential across the specimen may affect the air leakage rate.This is not addressed by this test method.1.3 This test method is intended for laboratory use. Personsinterested in performing field air leakage tests on installed unitsshould reference
6、 Test Method E 783.1.4 Persons using this procedure should be knowledgeablein the areas of fluid mechanics, instrumentation practices, andshall have a general understanding of fenestration products andcomponents.1.5 Throughout this test method, SI units are listed first inaccordance with E06 metric
7、policy, and shall be considered theprimary units. Non-SI units are provided in parenthesis forreference purposes.1.6 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate sa
8、fety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatement see Section 7.2. Referenced Documents2.1 ASTM Standards:2E 631 Terminology of Building ConstructionsE 783 Test Method for Field Measurement of Air LeakageThrough Installed
9、Exterior Windows and Doors3. Terminology3.1 DefinitionsTerms used in this standard are defined inTerminology E 631.3.2 Descriptions of Terms Specific to This Standard:3.2.1 air leakage rate (qAor ql), L/(sm2) (ft3/minft2), orL/(sm) (ft3/minft)the air leakage per unit of specimen area(A) or per unit
10、length of operable crack perimeter (l).3.2.2 extraneous air leakage (Qe), m3/s (ft3/min)the vol-ume of air flowing per unit of time through the test chamberand test apparatus, exclusive of the air flowing through the testspecimen, under a test pressure difference and test temperaturedifference, conv
11、erted to standard conditions.3.2.2.1 DiscussionExtraneous leakage is the sum of allleakage other than that intended to be measured by the test.3.2.3 specimenthe entire assembled unit submitted fortest as described in Section 7.3.2.4 specimen air leakage (Qs), L/s (ft3/min)the volumeof air flowing pe
12、r unit of time through the specimen under atest pressure difference and test temperature difference, con-verted to standard conditions.3.2.5 specimen area (A), m2(ft2)the area determined bythe overall dimensions of the frame that fits into the roughopening.3.2.6 standard test conditionsin this test
13、method, dry airat:Pressure101.3 kPa (29.92 in. Hg)Temperature20.8C (69.4F)Air Density1.202 kg/m3(0.075 lbm/ft3)1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.51on Performance of Windows, Doors, Skyligh
14、ts and Curtain Walls.Current edition approved March 1, 2004. Published March 2004. Originallyapproveed in 1965. Last previous edition approved in 1999 as E 283 91 (1999).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annu
15、al Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.7 test pressure differences, Pa (lbf/ft2)the specifieddifferential stati
16、c air pressure across the specimen.3.2.8 total air flow (Qt), L/s (ft3/min)the volume of airflowing per unit of time through the test chamber and testapparatus, inclusive of the air flowing through the test speci-men, under a test pressure difference and test temperaturedifference, converted to stan
17、dard conditions.3.2.9 unit length of operable crack perimeter (l), m (ft)thesum of all perimeters of operable ventilators, sash, or doorscontained in the test specimen, based on the overall dimensionsof such parts. Where two such operable parts meet the twoadjacent lengths of perimeter shall be coun
18、ted as only onelength.4. Summary of Test Method4.1 The test consists of sealing a test specimen into oragainst one face of an air chamber, supplying air to orexhausting air from the chamber at the rate required tomaintain the specified test pressure difference across thespecimen, and measuring the r
19、esultant air flow through thespecimen.5. Significance and Use5.1 This test method is a standard procedure for determiningthe air leakage characteristics under specified air pressuredifferences at ambient conditions.NOTE 2The air pressure differences acting across a building envelopevary greatly. The
20、 factors affecting air pressure differences and theimplications or the resulting air leakage relative to the environment withinbuildings are discussed in the literature.3,4,5These factors should be fullyconsidered in specifying the test pressure differences to be used.5.2 Rates of air leakage are so
21、metimes used for comparisonpurposes. Such comparisons may not be valid unless thecomponents being tested and compared are of essentially thesame size, configuration, and design.6. Apparatus6.1 The description of the apparatus in this section isgeneral in nature. Any suitable arrangement of equipment
22、capable of maintaining the required test tolerances is permitted.6.2 Test ChamberA well sealed box, wall, or other appa-ratus into or against which the specimen is mounted andsecured for testing. An air supply shall be provided to allow apositive or negative pressure differential to be applied acros
23、sthe specimen without significant extraneous losses. The cham-ber shall be capable of withstanding the differential testpressures that may be encountered in this procedure. At leastone static air pressure tap shall be provided on each side of thespecimen to measure the test pressure differences. The
24、 pressuretap shall be located in an area of the chamber in which pressurereadings will not be affected by any supply air. The air supplyopening to the chamber shall be located in an area in which itdoes not directly impinge upon the test specimen.6.2.1 Supply Air SystemA controllable blower, exhaust
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME2832004STANDARDTESTMETHODFORDETERMININGRATEOFAIRLEAKAGETHROUGHEXTERIORWINDOWSCURTAINWALLSANDDOORSUNDERSPECIFIEDPRESSUREDIFFERENCESACROSSTHESPECIMEN

链接地址:http://www.mydoc123.com/p-527296.html