ASTM E279-1997(2005) Standard Test Method for Determination of Abrasion Resistance of Iron Ore Pellets and Sinter by the Tumbler Test《铁矿丸和烧结矿抗磨性测定的试验方法》.pdf
《ASTM E279-1997(2005) Standard Test Method for Determination of Abrasion Resistance of Iron Ore Pellets and Sinter by the Tumbler Test《铁矿丸和烧结矿抗磨性测定的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E279-1997(2005) Standard Test Method for Determination of Abrasion Resistance of Iron Ore Pellets and Sinter by the Tumbler Test《铁矿丸和烧结矿抗磨性测定的试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 279 97 (Reapproved 2005)Standard Test Method forDetermination of Abrasion Resistance of Iron Ore Pelletsand Sinter by the Tumbler Test1This standard is issued under the fixed designation E 279; the number immediately following the designation indicates the year oforiginal adoption or,
2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a relative measure of theresistance of iron ore pellets
3、 and sinter to degradation byimpact and by abrasion.1.2 The values as stated in SI units are to be regarded as thestandard. The values in parentheses are given for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is therespo
4、nsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 135 Terminology Relating to Analytical Chemistry forMetals, Ores, and Related MaterialsE 2
5、76 Test Method for Particle Size or Screen Analysis atNo. 4 (4.75-mm) Sieve and Finer for Metal-Bearing Oresand Related MaterialsE 389 Test Method for Particle Size or Screen Analysis atNo. 4 (4.75-mm) Sieve and Coarser for Metal-BearingOres and Related MaterialsE 877 Practice for Sampling and Sampl
6、e Preparation of IronOres and Related MaterialsE 882 Guide for Accountability and Quality Control in theChemical Analysis Laboratory3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology E 135.4. Summary of Test Method4.1 The sample is placed in a tumbler
7、 drum which is rotated.The tumbled material is removed and screened to determine thedegradation.5. Significance and Use5.1 This test method is a comparative method intendedprimarily to test materials for compliance with compositionalspecifications or for monitoring. It is assumed that all who usethe
8、se procedures will be trained analysts capable of performingcommon laboratory procedures skillfully and safely. It isexpected that work will be performed in a properly equippedlaboratory and that proper waste disposal procedures will befollowed. Appropriate quality control practices must be fol-lowe
9、d such as those described in Guide E 882.5.2 This test method is used to monitor the feed to blastfurnaces for process control.6. Apparatus6.1 Tumbler Apparatus, as shown in Fig. 1, shall be acircular drum 914 mm (36 in.) in inside diameter and 457 mm(18 in.) in inside length constructed of steel pl
10、ate at least 6.3mm (14 in.) in thickness. The drum shall be replaced wheneverthe thickness of the plate is reduced by wear to 3.18 mm (18in.) in any area. Two equally spaced steel angle lifters, 50.8 by50.8 by 6.35 mm (2 by 2 by14 in.) shall be solidly attachedlongitudinally inside the drum by rivet
11、ing in such a manner asto prevent accumulation of material between the lifter anddrum. Preferably, one of the lifters shall be attached to the doorfor ease of sample removal. The lifters shall be fastened so thatthe attached legs point away from the direction of rotation, thusgiving a clear unobstru
12、cted shelf for lifting the sample. Thelifters shall be replaced when the wear is such that the shelfmeasures less than 47.6 mm (178 in.). The door shall be soconstructed as to fit into the drum to form a smooth innersurface and during the test shall be rigidly fastened to preventany loss of the samp
13、le. The drum shall be rotated on stub axlesabout 38.1 mm (112 in.) in diameter attached to the ends of thedrum by means of flanges welded or bolted so as to providesmooth inner surfaces. The apparatus shall be fitted with a1This test method is under the jurisdiction of ASTM Committee E01 onAnalytica
14、l Chemistry for Metals, Ores, and Related Materials and is the directresponsibility of Subcommittee E01.02 on Ores, Concentrates, and Related Metal-lurgical Materials.Current edition approved May 1, 2005. Published June 2005. Originallyapproved in 1965. Last previous edition approved in 2001 as E 27
15、9 97 (2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Dr
16、ive, PO Box C700, West Conshohocken, PA 19428-2959, United States.revolution counter and, preferably, with an automatic device tostop the drum after 200 revolutions.6.2 SievesSquare-mesh sieves having the following des-ignations are needed: 2-in. (50-mm); 112-in. (37.5-mm);34-in.(19.0-mm);12-in. (12
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME27919972005STANDARDTESTMETHODFORDETERMINATIONOFABRASIONRESISTANCEOFIRONOREPELLETSANDSINTERBYTHETUMBLERTEST

链接地址:http://www.mydoc123.com/p-527287.html